TECHNICAL SPECIFICATIONS

Flash coverage

Continuous flash
performance

AF illuminator

Flash control

Size

Weight

XX continuous cycles of X flashes per second
(Normal flash, 85mm, nickel-metal hydride
battery)

LED. Automatic with low-contrast subjects or
under low-light conditions
Approximate operating range
(with Maxxum/Dynax 7)

AF mid 1 area: 0.X - Xm

Flash control using pre-flash, TTL direct metering

65 (W) x 115 (H) x 69 (D) mm

230g (without batteries)

Specifications are based on the latest information available at the time
of printing and are subject to change without notice.

TECHNICAL

SPESIFICA

TIONS

• For every new battery set.

25 (in meters at ISO 100), 82 (in feet at ISO 100)

Guide number

Recycling time
(sec.)

Alkaline

Ni-MH

Lithium

0.2 - 5

0.2 - 4

0.2 - 5

Number of
flashes

Alkaline

Ni-MH

Lithium

400 - 4000

300 - 3000

600 - 10000

Equal to a 28mm focal length lens

This mark below the flashtube certifies that this
product meets the requirements of the EU (European
Union) concerning interference causing equipment
regulations. CE stands for conformité Européenne
(European conformity).

PF2500D_EngA.qxd  2003.05.27  06:29 PM  Page 34

Содержание MAXXUM FLASH 2500

Страница 1: ...PROGRAM FLASH MAXXUM FLASH BASIC OPERATION APPLICATIONS PF2500D_EngA qxd 2003 05 27 06 29 PM Page 1 ...

Страница 2: ...diately remove the batteries and discontinue use if the camera is dropped or subjected to an impact in which the interior especially the flash unit is exposed The flash has a high voltage circuit which may cause an electric shock resulting in injury The continued use of a damaged product or part may cause injuries Store this product out of reach of children Be careful when around children not to h...

Страница 3: ...nt does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and the receiver Connect the equipment to an outlet on a circuit different from that...

Страница 4: ... 14 With DiMAGE series digital cameras 17 EXPOSURE MODES 20 A Mode Flash 20 S Mode Flash 20 M Mode Flash 21 Flash Sync Speed 21 ADVANCED OPERATION BOUNCE FLASH 23 AF ILLUMINATOR 26 OFF CAMERA CABLES 27 Flash Ratio Control Varying the intensity of individual flash 28 APPENDIX COMPATIBILITY WITH OTHER PRODUCTS 30 CAUTIONS WHILE HANDLING 32 TECHNICAL SPECIFICATIONS 34 Thank you for purchasing this Mi...

Страница 5: ...charging Figures in parenthesis refer to the page number of relevant sections Mounting foot release button 12 Mounting foot 12 Flashtube AF illuminator 26 Autoflash lamp 14 Glows to indicate autoflash is active Turns off when using fill flash BASIC OPERATION The section covers how to prepare the flash for use as well as the basic flash operation Metering mode switch 13 Battery chamber door 10 PF25...

Страница 6: ... be powered by Four AA size alkaline batteries Four AA size lithium batteries Four AA size rechargeable nickel metal hydride Ni MH batteries Only charge nickel metal hydride batteries in an appropriate charger unit 1 Open the battery chamber door as shown 3 Close the battery chamber door 2 Insert the batteries as shown in the diagram in the battery chamber PF2500D_EngA qxd 2003 05 27 06 29 PM Page...

Страница 7: ...n switch to turn the flash on and off Select the flash metering mode when the flash is used with the Maxxum Dynax series cameras ADI flash metering is available with the ADI compatible cameras and D series lenses Refer to the camera s instruction manual for details When the flash is used with the DiMAGE series digital cameras the flash metering mode is set with the recording mode menu Refer to the...

Страница 8: ...he metering mode selected and the camera in use see chart below With the Maxxum Dynax 7 autoflash is used with full auto and fill flash with the P mode With the Maxxum Dynax 9 and 800si fill flash is used when the P mode is selected autoflash may also be selected as a custom setting with the 800si With other cameras autoflash is used with the P mode Fill flash can be selected in the same way as th...

Страница 9: ...When using slide film underexposure may be apparent at the farther limits of the flash range 1 Turn the camera and flash on 2 Set the P exposure mode on the camera With DiMAGE series digital cameras P MODE FLASH 3 Select the flash metering mode on recording mode menu 4 Press the shutter release button partway down With the DiMAGE A1 7Hi 7i 7 and 5 fill flash is used when the P mode is selected Con...

Страница 10: ...uction manual for details The photo will be under exposed if taken before the flash is completely charged When using the self timer confirm the flash is charged before pressing the shutter release button to start the countdown Flash range of the 2500 D in meters with the DiMAGE A1 7Hi 7i 7 5 If the subject is closer than 0 5m use the flash off camera with a cable Aperture F 2 8 4 5 6 8 11 Camera s...

Страница 11: ...rged press the shutter release button all the way down to take the picture M Mode Flash 1 Turn the camera on 2 Set the M exposure mode on the camera Fill flash is the active flash mode 3 Set the shutter speed and focus on the subject When using an SLR film camera the shutter speed should be set to the flash sync speed or slower The aperture will affect the flash range The larger the aperture the s...

Страница 12: ...iques and accessories Bounce flash Normal flash Direct flash illumination can cause harsh shadows on the subject and background Bounce flash reflects the light from the ceiling to create soft diffuse illumination BOUNCE FLASH Continued on next page PF2500D_EngA qxd 2003 05 27 06 29 PM Page 22 ...

Страница 13: ...ngth of lens Bounce angle 70mm minimum 45 28 70mm 60 28mm maximum 75 90 Correct Incorrect Determine the angle in relation to the table at right BOUNCE FLASH 24 With bounce flash using ADI metering can result in incorrect exposure Set the flash metering mode switch to TTL Use a white ceiling or wall to reflect the flash The color of a surface will affect the color of the flash illumination High cei...

Страница 14: ...to be placed to the left or right of the subject to create attractive side lighting Up to four flash units can be connected The following off camera accessories are available Off camera cable Off camera shoe Extension cable Cable CD Triple connector TC 1000 The off camera cable allows the flash to be used from any position The extension cable further extends of the distance of the flash from the c...

Страница 15: ...put difference between the main light and fill light the fill light controls the depth of the shadows 5600HS D 5400HS 5400xi 5200i The flash ratio cannot be set with this flash The ratio must be set with the compatible accessory flash unit See the flash manual for details Ratio control cannot be used with the DiMAGE A1 7Hi 7i 7 5 and Maxxum Dynax 300si The use of this function may result in incorr...

Страница 16: ...ode and the shutter speed is set automatically The use of ratio flash control will result in incorrect exposures when used with the 5000i and 3000i Using Early AF Series SLR Cameras Maxxum Minolta 9000 7000 5000 The optional flash shoe adapter FS 1200 is required See the FS 1200 manual for details COMPATIBILITY Using APS SLR Cameras Vectis S 1 Flash is set to autoflash in the P exposure mode Fill ...

Страница 17: ...rvice Facility for instructions CAUTIONS 32 During Photography This flash unit has an intense light output and should be fired directly in front of anyone s eyes Batteries Do not store the flash unit with the alkaline batteries inside Leakage from the batteries may damage the battery chamber When using alkaline batteries temperature and storage conditions can affect performance and may require mor...

Страница 18: ...cations are based on the latest information available at the time of printing and are subject to change without notice TECHNICAL SPESIFICATIONS For every new battery set 25 in meters at ISO 100 82 in feet at ISO 100 Guide number Recycling time sec Alkaline Ni MH Lithium 0 2 5 0 2 4 0 2 5 Number of flashes Alkaline Ni MH Lithium 400 4000 300 3000 600 10000 Equal to a 28mm focal length lens This mar...

Страница 19: ...r Seine France Minolta UK Limited 7 Tanners Drive Blakelands Milton Keynes MK14 5BU England Minolta Austria Ges m b H Amalienstrasse 59 61 A 1131 Wien Austria Minolta Camera Benelux B V Zonnebaan 39 P O Box 6000 NL 3600 HA Maarssen The Netherlands Belgian Branch Prins Boudewijnlaan 1 B 2550 Kontich Belgium Minolta Schweiz AG Riedstrasse 6 CH 8953 Dietikon Switzerland Minolta Svenska AB Albygatan 1...

Отзывы: