FrameMaker Ver.5.5(PC) Di251/Di351 TROUBLESHOOTING
05.03.01
T-29
4.
MALFUNCTION
The copier’s CPU is equipped with a self-diagnostics function that, on detecting a malfunc-
tion, gives the corresponding malfunction code on the Touch Panel.
Malfunction Resetting Procedure
• For all malfunctions except fusing-related ones, turn OFF, then ON the Power Switch or
open and close the Side Cover.
• Use “Trouble Reset” of the “Initial” mode to reset all malfunctions including fusing-related
ones.
4-1.
Detection Timing by Malfunction Code
Code
Description
Detection Timing
C0000
Main Motor malfunction
The Lock signal remains HIGH for a continuous 1-sec.
period while the Main Motor remains energized.
C0010
I/C Motor malfunction
The Lock signal remains HIGH for a continuous 1-sec.
period while the I/C Motor remains energized.
C0045
Cooling Fan Motor mal-
function
The Lock signal remains HIGH or LOW for a continu-
ous 1-sec. period or more while the Cooling Fan Motor
remains energized.
C004C Ozone Fan Motor mal-
function
The Lock signal remains HIGH or LOW for a continu-
ous 1-sec. period or more while the Ozone Fan Motor
remains energized.
C004E Power Unit Cooling Fan
Motor malfunction
The Lock signal remains HIGH or LOW for a continu-
ous 1-sec. period or more while the Power Unit Cool-
ing Fan Motor remains energized.
C0070
Main Hopper Toner
Replenishing Motor mal-
function
• The Toner Bottle Home Position Sensor remains
blocked (L) for a continuous 2-sec. period or more
while the Main Hopper Toner Replenishing Motor
remains energized.
• The Toner Bottle Home Position Sensor remains
unblocked (H) for a continuous 6-sec. period or
more while the Main Hopper Toner Replenishing
Motor remains energized.
C0214
Abnormal image transfer
voltage
The image transfer voltage remains more than 100 V
for a continuous 0.1-sec. period or more while the PC
Drum remains stationary (except while an F2 opera-
tion is being run).
C0500
Warming-up failure
The temperature of the Fusing Rollers does not reach
the required level even after the lapse of a given
period of time during a warm-up cycle.
• From room temperature to 100 °C: Within 65 sec.
• From 100 °C to 140 °C: Within 30 sec.
• From 140 °C to 170 °C: Within 20 sec.
• From 170 °C to the completion of warming-up:
Within 22 sec.
Содержание Di251
Страница 1: ...Di251 Di351 SERVICE MANUAL GENERAL 4011 7990 11 ...
Страница 2: ...INDEX GENERAL GENERAL MECHANICAL ELECTRICAL ...
Страница 3: ...GENERAL ...
Страница 18: ...MECHANICAL ELECTRICAL ...
Страница 24: ...M 4 3 DRIVE SYSTEM 1 Scanner Motor M10 2 Main Motor M2 3 I C Motor M1 1 3 2 4011M002AA ...
Страница 71: ...Di251 Di351 SERVICE MANUAL FIELD SERVICE 4011 7991 11 ...
Страница 82: ...INDEX FIELD SERVICE DIS REASSEMBLY ADJUSTMENT SWITCHES ON PWBs TECH REP SETTINGS TROUBLESHOOTING INSTALLATION ...
Страница 83: ...Di251 Di351 Allgemein Mechanik Elektrik Rev 1 1 0 03 01 I 1 INSTALLATION 3 ...
Страница 88: ...Di251 DI351 Rev 1 1 0 03 01 I 6 ...
Страница 93: ...I 5 Di251 Di351 Rev 11 0 0 03 01 10 Grounding plate screws 3 1 2 3 4 5 6 7 8 9 10 ...
Страница 99: ...I 11 Di251 Di351 Rev 11 0 0 03 01 6 Fit the Exit Tray 7 Close the Finisher Cover ...
Страница 107: ...I 19 Di251 Di351 Rev 11 0 0 03 01 1 5 3 Copy Tray Setting up Install the accessory copy tray in the shift tray unit ...
Страница 178: ...I 90 Di251 Di351 Rev 1 1 0 0 03 01 ...
Страница 179: ...DIS REASSEMBLY ADJUSTMENT 10230 ...
Страница 241: ...SWITCHES ON PWBs TECH REP SETTINGS 17196 ...
Страница 296: ...TROUBLESHOOTING 14413 ...