(2720)A 41
REP
AIR GUIDE
Adjustment of the frequency for camera shaking (ACT DRV FREQ)
Required equipment
PC with preinstalled the 2720 adjustment program
USB-500 (USB cable)
AC-1L/AC-11
Preparation of the adjustment
1. Start up the 2720 adjustment program.
2. Connect the camera and PC with USB-500, and click "START" after confirming the USB connection.
3. Set the lens block of the camera to "Wide-angle" position.
Procedure of the adjustment
1. Click "ACT DRV FREQ" of the adjustment menu.
The adjustment is automatically started.
2. The adjustment is completed when "OK" is displayed on the adjustment menu.
Adjustment of the servo for camera shaking (SERVO GAIN)
Required equipment
PC with preinstalled the 2720 adjustment program
USB-500 (USB cable)
AC-1L/AC-11
Preparation of the adjustment
1. Start up the 2720 adjustment program.
2. Connect the camera and PC with USB-500, and click "START" after confirming the USB connection.
3. Set the lens block of the camera to "Wide-angle" position.
Procedure of the adjustment
1. Click "SERVO GAIN" of the adjustment menu.
The adjustment is automatically started.
2. The adjustment is completed when "OK" is displayed on the adjustment menu.