7
Specifications:
Model Part No. System Volts Banks
Output
per Bank
(amps)
Total
Output
(amps)
Input
Cable
Output
Cable
Size L x W x H
Weight
(lbs)
Input Current
(120VAC, 60Hz)
MK230D
1822305
12 / 24
2
15
30
18AWG - 6'
14AWG - 6' 11-3/4" x 6-3/4" x 7"
17
5A
MK230DS
1822304
12 / 24
2
15
30
18AWG - 8.5' 14AWG - 6' 11-3/4" x 6-3/4" x 7"
17
5A
MK345D
1823455
12 / 24 / 36
3
15
45
18AWG - 6'
14AWG - 6' 11-3/4" x 6-3/4" x 8"
22
7A
MK345DS
1823454
12 / 24 / 36
3
15
45
18AWG - 8.5' 14AWG - 6' 11-3/4" x 6-3/4" x 8"
22
7A
MK460D
1824605 12 / 24 / 36 / 48
4
15
60
16AWG - 6'
14AWG - 6' 14-1/2" x 6-3/4" x 8"
31
10A
MK460DS
1824604 12 / 24 / 36 / 48
4
15
60
16AWG - 8.5' 14AWG - 6' 14-1/2" x 6-3/4" x 8"
31
10A
MK440D
1824405 12 / 24 / 36 / 48
4
10
40
18AWG - 6'
16AWG - 6' 11-3/4" x 6-3/4" x 8" 22.5
7A
9. TROUBLESHOOTING
PROBLEM:
Check Connection (Red) light comes on.
SOLUTION:
-Check polarity of leads to battery.
-Check connetions to battery and fuses in output cord.
-Check voltage at battery. The bank will not charge a battery below 4 volts or above 18 volts.
-If still not working, call the Minn Kota Service Department at 1-800-227-6433.
PROBLEM:
Check Connection (Red) light is flashing.
SOLUTION:
-The temperature sensor in the output cord is damaged. Check to make sure the output cord is not damaged. If the output cord was
extended, check to make sure the procedure in Section 6 was followed.
-If still not working, call the Minn Kota Service Department at 1-800-227-6433.
PROBLEM:
Indicator lights will not illuminate.
SOLUTION:
-Check the AC power at the outlet.
-Make sure the GFCI(Ground Fault Circuit Interrupter) o the outlet has not tripped.
-Check the AC power at the end of the extension cord.
-If still not working, call the Minn Kota Service Department at 1-800-227-6433.
PROBLEM:
The red and green lights are flashing.
SOLUTION:
-Check to make sure there are not any loads on the battery
-Check the fluid in the battery and add fluid if necessary.
-If the voltage of the battery does not increase above 10.5 volts after 3 hours or does not increase to the absorption voltage of 14.4 volts in 20 hours, then
the bank will shut down and will not charge. The battery should be tested.
-If still not working, call the Minn Kota Service Department at 1-800-227-6433.