background image

for at least 10 minutes and get medical attention immediately.

Never smoke or allow a spark or flame in vicinity of battery, engine, motor or other flammable or explosive equipment.

Be extra cautious to reduce risk of dropping a metal tool onto battery.  It might spark or short circuit battery or other electrical part that may 

cause explosion.

Remove personal metal items such as rings, bracelets, necklaces, and watches when working with a lead acid battery.  A lead acid battery can 

produce a short circuit current high enough to weld such items, causing severe burns.

Use the Minn Kota battery charger for charging and maintaining FLOODED / WET CELL, MAINTENANCE FREE, AND AGM / STARVED 

ELECTROLYTE batteries only. It is not intended to supply power to low voltage electrical systems other than for charging and maintaining bat-

teries.  Do not use the charger for charging dry-cell batteries that are commonly used with home appliances.  These batteries may burst and 

cause injury to persons and damage to property.

NEVER charge a frozen battery.

 

3. PREPARING TO CHARGE

1) If necessary to remove battery from boat or vehicle to charge or maintain, always remove grounded terminal from battery first (if applicable).  

Make sure all accessories in the boat or vehicle are off, so as not to cause an arc.

2) Be sure area around battery is well ventilated while battery is being charged or maintained.

3) Clean battery terminals.  Be careful to keep corrosion from coming in contact with eyes.

4) Add distilled water in each cell until battery acid reaches level specified by battery manufacturer ONLY AFTER the battery has been charged. 

Adding water to a discharged battery may result in acid leaking out of the battery and causing injury to persons and damage to property.  Do not 

overfill.  Study all battery manufacturers’ specific precautions; however, make sure to REPLACE ALL CELL CAPS after refilling so that water 

evaporation is avoided.  Water will evaporate over time if cell caps are not replaced after refilling. For a battery without removable cell caps, 

such as valve regulated lead acid batteries, carefully follow manufacturer’s recharging instructions.

NOTE: The battery fluid level should be checked every 30 days

  

5) Study all battery manufacturers’ specific precautions while charging and recommended rates of charge.

4. DC CONNECTION PRECAUTIONS

1) The Minn Kota charger will only charge 12 volt 6 cell lead acid batteries.  Do not connect the output of the charger to any other voltage or 

type of battery.

2) The charger’s DC output terminals are designed to be permanently mounted and connected to batteries.

3) Connect and disconnect DC output terminals only after removing the AC plug from the electric outlet.

4) The charger output leads must be connected with the correct polarity for the charger to function.  The RED lead must be connected to the 

POSITIVE terminal of the battery and the BLACK lead must be connected to the NEGATIVE terminal of the battery.  

See section 6 under 

“CONNECTING THE BATTERIES TO THE CHARGER” for proper connection procedure.

5. GROUNDING AND AC POWER CORD CONNECTION INSTRUCTIONS

The Minn Kota battery charger should be grounded to reduce risk of electric shock.  The charger is equipped with an electric AC power cord 

with a grounded plug.  The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and 

ordinances.

DANGER

 – Never alter AC cord or plug provided – if it will not fit outlet, have proper outlet installed by a qualified electrician.  Improper con-

nection can result in a risk of an electric shock.

CAUTION

 – To reduce risk of fire or electric shock, connect battery charger directly to grounding receptacle (three-prong).  An adapter should 

not be used with battery charger.

3

Содержание 1821065

Страница 1: ...CHARGERS Models MK106D Service Information Please call our service department at 800 227 6433 if you have any problems with your battery charger A technical support representative will be happy to as...

Страница 2: ...y way Do not disassemble the charger Incorrect reassembly may result in a risk of electric shock or fire To reduce risk of electric shock unplug the charger from outlet before attempting any maintenan...

Страница 3: ...ll battery manufacturers specific precautions however make sure to REPLACE ALL CELL CAPS after refilling so that water evaporation is avoided Water will evaporate over time if cell caps are not replac...

Страница 4: ...e Mount the AC plug holder with four screws in a convenient dry site to prevent corrosion to the AC plug and to prevent the AC plug from making contact with the battery posts CONNECTING THE BATTERIES...

Страница 5: ...g will be displayed on the charger A GREEN power light is lit to indicate AC power is applied Each bank has YELLOW GREEN and RED lights to indicate charging status and error conditions Minn Kota s Mul...

Страница 6: ...iance could void the user s authority to oper ate the equipment NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rule...

Страница 7: ...t cord was extended check to make sure the procedure in Section 6 was followed If still not working call the Minn Kota Service Department at 1 800 227 6433 PROBLEM Indicator lights will not illuminate...

Страница 8: ...ould dispose of your waste equipment for recycling and recovery and or your European Union member state requirements please contact your dealer or distributor from which your product was purchased Too...

Страница 9: ...NTIAL OR SPE CIAL DAMAGES Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so the above limitations and...

Отзывы: