background image

5

ELECTRICAL CONNECTIONS

     NOTE: This fan includes a WC105 wall control. If you are to add a light 
kit you would need to purchase the WC106 wall control. (Available at your 
Minka-Aire

®

 retailer.)

NOTE: If you feel that you do not have enough electrical wiring knowledge 
or experience, have your fan installed by a licensed electrician.

Use the wire nuts supplied with your fan. Secure the connectors with 
electrical tape and make sure there are no loose connections or wire 
strands.

1. Connect the wiring from the fan motor to house supply. (Fig. 11)
    Connect the RED live supply wire to the BLUE fan light wire. 
    Connect the BLACK live supply wire to the BLACK fan live wire. 
    Connect the WHITE neutral wire to the WHITE fan neutral wire.
    Connect the COPPER house ground wire to the GREEN fan ground wire.

2. After connecting the wires, spread them apart so that  the green and 
white wires are on one side of the outlet box and the black wires are on 
the other side.

3. Connect the wiring from the wall switch receptacle to wall control 
unit. (Fig. 11)
    Remove the existing wall plate and switch from the wall junction box. 
   Connect one BLACK wire from the wall to one BLACK wire (labeled "TO 

FAN") from the wall control.

   Connect the other BLACK wire (labeled "TO POWER SUPPLY") from the 

wall control to the remaining BLACK wire from the wall (A/C supply 
source).

4. If your junction box has a ground wire (green or bare copper), connect 
the wall control's ground wire to it. Otherwise, connect the wall control 
ground wire directly to one of the screws from the outlet box.

Содержание STEAL F729

Страница 1: ...INSTRUCTION MANUAL WARRANTY CERTIFICATE STEAL BY...

Страница 2: ...2017 Minka Lighting Inc Manual design and all elements of manual design are protected by U S Federal and or State Law including Patent Trademark and or Copyright laws...

Страница 3: ...Aire ceiling fan excluding wall controls and electrical components to the original purchaser or user The warranty is voided with the use of any non Minka Aire electrical devices E g wall controls or...

Страница 4: ...claim Replacement is subject to availability of the same model If the model is unavailable it will be replaced by one of equal value This is a limited warranty the original purchaser or user is respo...

Страница 5: ...INSTALLING THE WALL CONTROL FINISHING THE INSTALLATION BLADE INSTALLATION ATTACHING THE SWITCH CUP OPERATING THE WALL CONTROL CARE OF YOUR FAN TROUBLESHOOTING SPECIFICATIONS 1 2 3 4 5 6 7 8 9 10 11 12...

Страница 6: ...x use a U L Listed metal octagonal outlet box marked Acceptable for Fan Support Secure the box directly to the building structure The outlet box and its support must be able to support the moving weig...

Страница 7: ...DUCE THE RISK OF PERSONAL INJURY DO NOT BEND THE BLADE HOLDERS WHILE INSTALLING BALANCING THE BLADES OR CLEANING THE FAN DO NOT INSERT FOREIGN OBJECTS BETWEEN ROTATING FAN BLADES TO REDUCE THE RISK OF...

Страница 8: ...ware 1 4 x 1 2 mm Allen screws 7PCs C Allen wrench 3mm Allen wrench 5mm 1 Fan blades 3 2 Hanger bracket 3 Canopy 4 Canopy cover 5 Downrod assembly 6 Coupling cover 7 Fan motor housing assembly 8 Switc...

Страница 9: ...t ways to mount the outlet box Note You may need a longer downrod to maintain proper blade clearance when installing on a steep sloped ceiling Longer downrods are available from your Minka Aire dealer...

Страница 10: ...om the top coupling of the motor assembly Fig 6 Step 3 Remove hanger ball from downrod assembly by loosening set screw removing the cross pin and sliding ball off rod Fig 7 Step 4 Carefully feed fan w...

Страница 11: ...6 Fig 10 Fig 9 CANOPY COVER OUTLET BOX HANGER BRACKET DOWNROD SUPPLY WIRES REGISTRATION SLOT CROSS PIN HANGER BALL DOWNROD HITCH PIN LOCK PIN SET SCREWS SET SCREW DOWNROD CANOPY SET SCREWS HITCH PIN L...

Страница 12: ...ct the WHITE neutral wire to the WHITE fan neutral wire Connect the COPPER house ground wire to the GREEN fan ground wire 2 After connecting the wires spread them apart so that the green and white wir...

Страница 13: ...Fig 11 WHITE NEUTRAL LINE VOLTAGE BLACK WIRE FROM MAIN FUSE BOX GROUND BLACK BLACK BLACK YELLOW GREEN BLUE RED GREEN WHITE WHITE GROUND CONDUCTOR BLACK BLACK OUTLET BOX...

Страница 14: ...shown in Fig 11 If your outlet box has a ground wire Green or Bare Copper connect the wall control s ground wire directly to one of the screws from the outlet box Secure all wire connections with the...

Страница 15: ...er the screw on the hanger bracket turn canopy until it locks in place at the narrow section of the key holes Fig 13 Step 3 Align the circular hole on canopy with the remaining hole on the hanger brac...

Страница 16: ...t the blades are at least 3 0M 10 feet above the floor 1 Insert the blade into the fan motor align holes from blade to fan motor and secure with two Allen screws and Allen wrench provided Fig 14 2 Rep...

Страница 17: ...wire connectors together Fig 15 Step 2 Remove the screws from the switch cup plate Slide switch cup up against plate and rotate it until the screw holes are aligned Secure with the Allen screws and Al...

Страница 18: ...control is used to set the fan speed as follows Fig 16 0 Turns the fan off 1 High Speed 2 Medium High Speed 3 Medium Speed 4 Low Speed 2 Light Control Your ceiling fan is equipped with a light howeve...

Страница 19: ...3 If your fan is provided with wood veneer blades you can apply a light coat of furniture polish for additional protection and enhanced beauty Cover small scratches with a light application of shoe po...

Страница 20: ...transmitter connections if applicable SOLUTION SYMPTOM Fan Sounds Noisy Allow a 24 hour break in period Most noises associated with a new fan will go away during this time Make sure the screws that a...

Страница 21: ...s are grouped by weight Make sure outlet box is secured to building structure if necessary use the wood screws provided to further secure outlet box to joist Make sure hanger bracket is secure to the...

Страница 22: ...20 Volts Speed Low High SPECIFICATIONS These are typical readings Your actual fan may vary They do not include amps and wattage used by the light s Amps 0 17 0 52 Watts 7 63 RPM 65 224 N W 7 93 kgs G...

Страница 23: ...1 800 307 3267 Ceiling fan airflow is measured in cubic feet per minute CFM Power use is measured in watts To maximize energy savings Choose a fan with high airflow efficiency CFM watt Use ENERGY STA...