![Minipa MTR-1522 Скачать руководство пользователя страница 14](http://html.mh-extra.com/html/minipa/mtr-1522/mtr-1522_instruction-manual_1802398014.webp)
13
Press “LIGHT/LOAD” again then the display will show the
saved data number 02 e so on until the 20th saved data.
If you want to return to previous data, press “HOLD/SAVE”
once (in this case, “HOLD/SAVE” and “LIGHT/LOAD” are
working as “up” and “down”).
To disable the function, press “LIGHT/LOAD” for two seconds.
3. Erase the saved data:
press the buttons “HOLD/SAVE”
and “LIGHT/LOAD” simultaneously then turn on the device.
The display will show “C L.” and all the data will be erased.
9) Specification
A. General Specification
● Display:
LCD 3 3/4 digits, 4000 counts
● Functions:
Earth voltage measure and earth resistance
measure.
● Over Range Indications :
“OL” is shown.
● Auto Power Off:
10 minutes.
● Data Hold
● 3 and 4 Wires Tests.
● Internal memory:
20 data.
● Temperature:
Operation: 5°C ~ 40°C, RH ≤ 80%
Storage: -20°C ~ 60°C, RH ≤ 75%
● Altitude:
Under 2000m.
● Alimentation:
6 batteries AA 1,5V.
● Conformity:
IEC 61557-1, IEC 61557-1,5, IEC 61010-2-31,
IEC 61010-1, CAT III 600V.
● Pollution Degree:
2
● Dimentions:
160(A) x 70,5(L) x 100(P)mm
● Weight:
about 560g.