background image

 

User Manual

 

 

 
 
Revised on 05/09/2022 

 

Page 4 

 

 

These User Instructions are for guidance for all SmartCube model SC-40T and DualBar units available.  

 
To obtain the best possible performance and trouble free operation for your SmartCube it is very important to 
carefully read these instructions  before user and observe the important safety information detailed. 

 
1. 

Unpacking the SmartCube

 

 

When unpacking the product, check for damage and missing parts. Damage in transit must be reported 
immediately to the carriers and your Minibar representative. 

 

The SmartCube’s electronic service tray is not designed to bear weight.  Do not stack SmartCube’s or 
place heavy objects on top during transit to the guest room. Heavy objects would include items such as 
a television, case good, etc. 

 

Dispose of the packaging in accordance with your local recycling ordinances. 
 

2. 

Electrical Safety

 

•  Before installation, check the following IMPORTANT items for ELECTRICAL SAFETY and to obtain the best 

performance from your SmartCube.

 

•  Before connecting the SmartCube to the mains power wall socket, verify the voltage stated on the 

product rating plate (inside the cold cube) is the same as the mains voltage supplied to the wall socket. 

 

•  A standard AC mains outlet plug (socket) with safety ground is provided. The AC mains supply to the 

SmartCube must be clean and stable.

 

•  Make sure the mains power cord or any other cables are not trapped under the unit.

 

•  If the mains power cord is damaged, at any time, it must be replaced by Minibar Systems, its service agent 

or similarly qualified person in order to avoid a hazard.

 

•  The use of an extension cord is not recommended.

 

•  Minibar Systems cannot be held responsible if these measures are not observed. 

 

 
3.   

FCC Statement: 

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to 
part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful 
interference in a residential installation. This equipment generates, uses and can radiate radio frequency 
energy, and if not installed and used in accordance with the instructions, may cause harmful interference to 
radio communications. However, there is no guarantee that interference will not occur in a particular 
installation. If this equipment does cause harmful interference to radio or television reception, which can be 
determined by turning the equipment off and on, the user is encouraged to try to correct the interference by 
one or more of the following measures: 

 

Reorient or relocate the receiving antenna.  

 

Increase the separation between the equipment and receiver. 

 

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.  

 

Consult the dealer or an experienced radio/TV technician for help.  

 

Содержание SMARTCUBE DualBar

Страница 1: ...User Manual Revised on 05 09 2022 Page 1 MINIBAR SYSTEMS USER MANUAL Installation Instructions Operating Instructions and Case Good Specifications Models SC 40T and DualBar...

Страница 2: ...al Electronic Lock 14 6 Temperature Regulation 15 7 Enabling and Disabling Optional Lighting 15 8 Communications 16 9 Routine Maintenance and Cleaning 16 10 Installation Instructions 17 10 1 Door Shel...

Страница 3: ...or explosion This appliance is intended to be used in household and similar applications such as o staff kitchen areas in shops offices and other working environments o farm houses and by clients in...

Страница 4: ...ly to the SmartCube must be clean and stable Make sure the mains power cord or any other cables are not trapped under the unit If the mains power cord is damaged at any time it must be replaced by Min...

Страница 5: ...proper ventilation for the SmartCube is imperative to ensure maximum efficient operation of the cooling unit The SmartCube must not be placed against a heating radiator window direct sunlight or curta...

Страница 6: ...d to prevent the case good from being pushed against the wall The underside of the shelf above the SmartCube must be flat so no obstruction is caused to the airflow In this instance the back of the un...

Страница 7: ...7 475 mm DualBar 22 92 582 4 mm 28 465 723 mm 18 7 475 mm Insertable Cavity Opening see Diagram A in Section 4 Height Width Depth SC 40 26 66 677 mm 20 47 520 mm 23 43 595 mm GF 27 26 66 677 mm 16 532...

Страница 8: ...59 mm 13 330 2 mm 3 65 92 71 mm 8 sensors 85 21 59 mm 13 330 2 mm 6 3 160 02 mm 10 sensors 85 21 59 mm 16 1 409 mm 6 3 160 02 mm SmartTrays come in the following leatherette Short configurations Smar...

Страница 9: ...onfigurations SmartTray Height Width Depth 4 sensor Leatherette 3 125 79 38 mm 14 8 375 92 mm 4 8125 122 2375 mm 8 sensor Leatherette 3 125 79 38 mm 14 8 375 92 mm 8 0625 204 787 mm 10 sensor Leathere...

Страница 10: ...114 3 mm 4 5 114 3 mm Two single sensors 2 5 63 5 mm 9 228 6 mm 4 5 114 3 mm 4 sensor Flat Tray 2 5 63 5 mm 16 125 409 57 mm 6 75 171 45 mm 8 sensor Flat Tray 1 875 47 63 mm 16 5 419 1 mm 9 625 244 48...

Страница 11: ...ivider wall in the case good if an optional electronic lock and or ambient snack trays are installed The diagram illustrates drilling for both right hand and left hand hinged bars If the ambient snack...

Страница 12: ...All dimensions are internal Placement of bar begins 0 5 13 mm inside the case good door All tolerances 0 12 3 mm If the key is stored in the minibar lock allow an additional 1 2 30 mm 8 203 2 mm reco...

Страница 13: ...e For safety secure or anchor the SmartCube to the floor using screws appropriate for the material and thickness of the case good floor Holes can be found in each front foot and covers are provided fo...

Страница 14: ...sistance See Section 3 3 if using multiple trays hole placement may vary All dimensions are internal All tolerances 0 12 3 mm Roller catches are not required if optional electronic lock is used Not to...

Страница 15: ...etting can be adjusted by rotating the dial MAX is for maximum cooling Enabling and Disabling Optional Lighting SmartCube has a standard exterior and interior lighting feature for Flexi and Automated...

Страница 16: ...and Cleaning If the unit is fitted with an absorption cooling unit it is recommended on an annual basis to check for any leakage or small yellow type stains If present change the cooling unit Please c...

Страница 17: ...Door Shelf Replacement To remove the door mounted shelf you will need to first remove the rubber plug on the left side of the door shelf column that is protecting the un used backplane connector Free...

Страница 18: ...ual 2021 Page 18 The door rack will now be loose and able to slide out the upper and lower door rack kit Un screw the right side door shelf column using a Philips head screw driver and remove the shel...

Страница 19: ...User Manual 2021 Page 19 Disconnect door sensor shelf from the backplane board and the release engagement feature by sliding door sensor shelf to the right Remove the sensor shelves for replacement...

Страница 20: ...shelf MB MA 0035 into the bottom support and connect it to the backpane Screw the right side door shelf column using a Philips head screw driver to secure the sensor shelves Slide the rack kit between...

Страница 21: ...User Manual 2021 Page 21 Install the rubber plug back to cover the un used backplane connector...

Страница 22: ...the lock bar that is located on the right side inner wall of the SmartCube minibar To unlock the sensor shelves from the backplane frame lift up on the locking bar Slide out the sensor shelves carefu...

Страница 23: ...ividers MB PP 0005 and PULF0015 to the sensor shelves Once assembled onto sensor shelf MB MA 0034 slide the sensor shelves in the slots of the cube to connect onto the backplane connectors Push down o...

Страница 24: ...Page 24 Console Box Replacement Switch off the Console Box power supply unit and then disconnect all cables from it Un Screw the Console Box from the back of the SmartCube by removing three Philips he...

Страница 25: ...nstallation Mount the Console Box to the SmartCube back using 2 Round Philips Head screws MB NP 0027 and 1 Flat Philips Head screw MB NP 0029 Connect all cables back according to the wiring diagram an...

Страница 26: ...ide Enabled when electronics malfunctions Open the lock cover by removing the Philips Head screw using a screw driver Press the override pusher head down and rotate by 90 degrees in a clockwise direct...

Страница 27: ...ronics functions Press the override head down and rotate it by 90 derees in the counter clockwise direction to release the locking bar to resume E lock function Screw the anti tamper cover back ono th...

Страница 28: ...nsional drawing for proper ventilation Reference to the dimensional drawings Fix the rear anchor bracket onto the case good using the gauge template or refer to the dimensional drawing for mounting lo...

Страница 29: ...ord is connected to the SmartCube and then push the SmartCube SC 40T into the cabinet against the rear anchor bracket Connect the other end of the IEC power cord MB CA 0016 to the SmartCube GuestFridg...

Страница 30: ...s to case good open doors and the bracket is located on the bottom lip of the cold cube Screws MB NP 0026 packed in accessory back along with the bracket Casegood ventilation is emparative to unit fun...

Страница 31: ...ensional drawing for proper ventilation Reference to the dimensional drawings Fix the rear anchor bracket onto the case good using the gauge template or refer to the dimensional drawing for mounting l...

Страница 32: ...ase good Open the door to screw the bottom of the SmartCube to the case good Screws MB NP 0026 packed in accessory back along with the bracket Casegood ventilation is emparative to unit function and o...

Страница 33: ...nformation contact your Minibar Systems representative The majority of all plastic parts are marked with an internationally standardized abbreviation for graded recycling This will enable plastic wast...

Страница 34: ...ne FR 92508 Rueil Malmaison Cedex tel 33 1 55 47 07 07 fax 33 1 47 49 61 62 minibar france minibar ch www minibar ch Germany Minibar Germany GmbH Co Venloer Strasse 151 153 D 50672 K ln tel 49 2271 99...

Отзывы: