manualshive.com logo in svg
background image

3

IMPORTANT SAFETY PRECAUTIONS!

WARNING: Do not use product until you have read and understand
instructions and precautions.

Submersible Systems, Inc. promotes responsible diving practices and the 
recommendations that have been promoted by all International Training agencies,
including, but not limited to:
• Before any attempt is made to use this product underwater, you MUST have

received TRAINING and CERTIFICATION in the technique of SCUBA diving from
a recognized certification agency. Use of this equipment by a person who is not
certified by a recognized agency shall render all warranties, express or implied,
null and void. Use of underwater breathing devices by uncertified or untrained
persons is dangerous and can result in severe injury or death.

• SPARE AIR is an EMERGENCY alternate air source. It is NOT designed or

intended for any other use.

• SPARE AIR should not be used as part of your planned air reserve.
• SPARE AIR does not meet the requirements of EN 250; 1993 and therefore

should never be used as a primary air source.

• SPARE AIR is intended for use in water greater or equal to 10 degrees Celsius.
• Recommended Max ascent rates: 15 meters per minute (6 meters per minute

for the last 6 meters).

• Swimming diver accepted as 25 Iiters/min., non-swimming will be less.
• Monitor diving disorders if ascent rates are exceeded or decompression stops

are missed.

• Max depth recommendation is 20 meters (66 ft) for model #170.
• Max depth recommendation is 30 meters (99 ft) for model #300/300-N.
• Practice using SPARE AIR at normal rate ascents in shallow water.
• ALWAYS follow Submersible Systems’ recommended pre-dive standards/post-

dive checklist and annual inspection/repair guidelines.

• NEVER dive with a SPARE AIR system that shows signs of damage, leakage or

substandard performance.

• NEVER OVERFILL the SPARE AIR system above 3000 psi, the air pressure

stamped on the cylinder. ONLY use purified, dry compressed breathing air when
refilling SPARE AIR.

• STORE THE SPARE AIR system PRESSURIZED in a cool, dry place. Avoid

direct sunlight, automobile trunks or other areas subject to temperature
extremes.

• In Europe, Cylinders fitted to SPARE AIR should meet national regulations and

be tested and inspected in accordance with national regulations.

• EC type approval conducted by:  SGS United Kingdom, Ltd., Ellesmere Port,

Cheshire, CH65 3EN, UK. Notified Body No. 0120. This item complies with MOD
(PE) Specification RO347. May 1991.

• This manual is supplied to the original SPARE AIR purchaser. Duplicate copies

can be obtained free of charge from Submersible Systems, Inc.

Содержание SPARE AIR

Страница 1: ...OWNER S MANUAL SPARE AIR MADE IN USA ...

Страница 2: ...ruction of this product Enjoy the peace of mind that diving with SPARE AIR brings TABLE OF CONTENTS Safety Precautions 3 SPARE AIR Diagram Specifications 4 Accessory Diagrams 5 6 Before You Dive WITH SPARE AIR 7 How To Mount SPARE AIR 7 How To Operate SPARE AIR 8 Warranty Information INSERT After You Dive With SPARE AIR 9 Product Compatibility And Use With Nitrox Model 300 N 10 How To Care For SPA...

Страница 3: ...s per minute for the last 6 meters Swimming diver accepted as 25 Iiters min non swimming will be less Monitor diving disorders if ascent rates are exceeded or decompression stops are missed Max depth recommendation is 20 meters 66 ft for model 170 Max depth recommendation is 30 meters 99 ft for model 300 300 N Practice using SPARE AIR at normal rate ascents in shallow water ALWAYS follow Submersib...

Страница 4: ...gth 13 4 34 cm 8 75 22 23 cm Diameter 2 25 5 71 cm 2 25 5 71 cm Maximum Pressure 3000 psi 200 bar 3000 psi 200 bar Weight full 2 17 lb 985 kg 1 51 lb 687 kg Surface Breaths 57 30 Water Volume 26 62 cu in 42 liters 13 7 cu in 28 liters Based on 1 6 liter breath size optional SPARE AIR DIAGRAM PURGE BUTTON Refill Port ...

Страница 5: ...Mount SPARE AIR in a variety of locations on virtually any BCD 5 ACCESSORIES Included In Package SPARE AIR HOLSTER 973 Upside Down On Your Tank Strap Vertical On Your BC Across Your Waist Diagonal ...

Страница 6: ...6 ACCESSORIES Included in Package SPARE AIR REFILL ADAPTER 910S Adapter fits onto Standard SCUBA tank for easy refilling ...

Страница 7: ...tain full pressure in SPARE AIR do not use purge unnecessarily Make sure SPARE AIR is mounted firmly and adjusted properly in Holster before entering the water Velcro must be fully engaged NOTE For added security a safety leash lanyard is recommended so that SPARE AIR is not lost if it is dislodged dropped or released by accident Hold SPARE AIR secure with a free hand on entry into the water or in...

Страница 8: ...f Holster to open CAUTION Begin ascending immediately to avoid using valuable time and air 2 Grab SPARE AIR regulator head and pull out of the Holster This action will release the Mouthpiece Cover 3 Place SPARE AIR into user s mouth 4 Press Purge Button lightly or exhale sharply to clear regulator before inhaling CAUTION Failure to purge the SPARE AIR regulator before inhaling will result in swall...

Страница 9: ... a completely independent air supply Submersible Systems is proud of the fact that we contribute to divers safety Every year more and more lives are saved because of SPARE AIR SPARE AIR continues to be refined out of our commitment to provide our customers with a Simply Dependable product SPARE AIR is made entirely in the U S A by craftsmen dedicated to producing a quality product Send in your war...

Страница 10: ...f purchase This warranty is non transferable and applies to the original purchaser only How to obtain warranty service You must return your product to Submersible Systems to obtain warranty service You must provide a copy of the original sales receipt and a copy of the owner s portion of this warranty registration Freight must be prepaid Please enclose a letter with your daytime telephone number d...

Страница 11: ... 7 Average Number of Dives per Year 1 12 13 25 26 50 51 100 100 Certification Level Advanced Rescue Divemaster Open water Instructor Other Age Group Under 18 18 25 26 35 36 45 46 50 51 Sex Male Female What influenced your purchase Magazine ad Magazine editorial Brochure Store display Store personnel Instructor Dive Buddy Other ____________________________________________________________________ Oc...

Страница 12: ...ESSARY IF MAILED IN THE UNITED STATES BUSINESS REPLY MAIL FIRST CLASS MAIL PERMIT NO 1243 HUNTINGTON BEACH CA POSTAGE WILL BE PAID BY ADDRESSEE SUBMERSIBLE SYSTEMS INC 18072 GOTHARD ST HUNTINGTON BEACH CA 92648 9942 ...

Страница 13: ...ubmersible Systems Inc for service and or check up 3 Remove SPARE AIR from the Holster to rinse and dry 4 With pressure in the SPARE AIR rinse or soak in fresh water for 30 minutes and run fresh water inside the mouthpiece and around the regulator 5 Shake excess water from the system and dry thoroughly CAUTION Never use chemicals or solvents to clean SPARE AIR PRODUCT COMPATIBILITY AND USE WITH NI...

Страница 14: ...ll help to ensure the maximum life of your SPARE AIR system SPARE AIR should be serviced ANNUALLY by an Authorized SPARE AIR Dealer or by Submersible Systems Inc If you notice damage wear or suspect any leaking or missing parts have SPARE AIR examined by an Authorized SPARE AIR Dealer immediately WARNING DO NOT attempt to repair SPARE AIR yourself Unauthorized repairs or tampering are hazardous an...

Страница 15: ...reassemble Spare Air and refill You may lightly lubricate the tank 0 ring with a small amount of silicone spray or grease never use a hydrocarbon based oil Do not force regulator onto tank if you feel resistance stop and unscrew and start again 6 Replace tank o ring after product has been disassembled and re assembled 3 times or o ring shows signs of wear or air leakage 7 Keep Spare Air regulator ...

Страница 16: ...crew easily 1 Unscrew black knurled Cap from the SPARE AIR Check Valve filling port 2 Place the Adapter onto Check Valve and turn the knurled part of the adapter to the right until finger tight 3 Attach Adapter to SCUBA tank valve 4 Fill Important Gently open SCUBA valve to fill slowly take 45 60 seconds to fill The pin on the Pressure Indicator will rise while filling and when flush with the top ...

Страница 17: ...hen the pressure indicator will not show full and your SPARE AIR will not be filled to its recommended full capacity diminishing available air volume WARNING If the SPARE AIR check valve or adapter threads are damaged or worn these parts will require replacement Continued use may cause injury If you have any questions concerning this product please call Submersible Systems Inc Customer Service at ...

Страница 18: ...______________________________________________ Comments ___________________________________________________________________________________________________ ____________________________________________________________________________________________________________________ Date ____________________________________________________________________________________________________________ By __________...

Страница 19: ...g Abroad 15 00 Total Name _____________________________________________________ Address _____________________________________________________ City State Zip ________________________________________________ Country _____________________________________________________ Phone ___________ __________________________________________ Method of Payment Check Enclosed VISA MasterCard AMEX circle one Credit...

Страница 20: ...reet Huntington Beach CA 92648 USA or Log on to our website at www spareair com to purchase SPARE AIR Accessories Distributor Stamp 18072 Gothard Street Huntington Beach CA 92648 USA 800 648 3483 P 714 842 6566 F 714 842 4626 www spareair com Rev 5 04 098128NX ...

Отзывы: