mini-box DCDC-USB-200 Скачать руководство пользователя страница 5

mini-itx.com 

  

ATX DC-DC Converter Series 

DCDC-USB-200 Quick Installation Guide 

Page 5 

Electrical and Environmental Specifications 
 

Minimum Input Operating  voltage 

6V 

Maximum input Operating voltage 

Electronic shut down at 34V (clamping will occur 
34-36V) 

Deep-Discharge shutdown threshold 

11.2V 

Input current limit  

15A (20 A mini-blade fuse) 

Max Output Power (peak) 

160 watts or 15A input current 

Regulation accuracy 

2.5%  

Operating temperature 

-40 to +85 degrees Celsius 

Storage temperature 

-55  to +85 degrees Celsius 

MTBF 

>100,000 hrs @ 65C body temp. 

Efficiency (Input 9-16V) 

>94% (output = 12V 2A) 

PCB size 

160mx45mm 

Input, output connectors 

Right angle, Mini-FIT JR 4 pin 

 

*NOTE: At output power greater than 60watts or if unit temperature exceeds 
65C, forced air ventilation will be required in order to prevent unit from excessive 
thermal stress for long period of times. 

 
12V output max current charts 
 

Input (V) 

12V rail current 

Input (V)  

12V rail current 

6V 

6A 

11V 

12A 

7V 

7A 

12V 

12A (15A peak) 

8V 

8A 

14V 

12A (15A peak) 

9V 

9A 

14-18V 

12A (15A peak) 

10V 

10A 

20-32V 

10A 

 

NOTE: Peak consumption should not exceed 60 sec, forced ventilation required.  

 
Operating environment

: Temperature: -20 to 65 degree centigrade. 

Relative Humidity: 10 to 90 percent, non-condensing.   
 

Efficiency, MTBF: 

MTBF >100K hours at PSU(temp) < 65 Celsius.  

NOTE: All solid polymer capacitor design, rated >50K hours at 85C or 500K 
hours at 65C.  
 

Shipping and storage: 

Temperature -40 to +85 degree centigrade. Relative 

humidity 5 to 95 percent, non-condensing. 
 
  
  

Содержание DCDC-USB-200

Страница 1: ...USB converters Features include USB interface programmable output voltage and scripting as well as automotive modes The DCDC USB 200 device is able to send ON OFF pulse signals to motherboards based on voltage levels or Ignition sensing making it an ideal device for automotive or battery powered installations This unit has a wide input range 6 34V and it can provide a tightly regulated output rang...

Страница 2: ... settings J1 USB header for internal connection D1 STATE State LED J10 Provides unregulated switched input to be used in automotive modes to power various peripherals Basic Operation For basic operation you would need to connect a power source to V IN V IN is on the left side of the board near the input fuse Polarity is marked on the PCB GND VIN and Ignition On the cable harness GND is black V in ...

Страница 3: ...r change the DCDC USB 200 unit needs to be power cycled in order for the new setting to take effect NOTE Finer voltage adjustments are available via USB settings see Advanced USB Configuration manual Configuration Mode of Operation DCDC USB 200 has 4 modes of operation This modes can be changed via jumpers 1 DUMB mode The units acts as a regular DC DC converter Only V In and V out and GND terminal...

Страница 4: ... Timing Schemes When unit is set to operate in the Automotive Mode 8 timing settings are available These are combinations of OFFDELAY and HARDOFF timers NOTE These settings work only when the Ignition wire is used OFFDEALAY is the amount of time the unit waits until it sends an ON OFF pulse the motherboard s ON OFF pins after Ignition has been turned off HARDOFF is the amount of time the unit will...

Страница 5: ...Mini FIT JR 4 pin NOTE At output power greater than 60watts or if unit temperature exceeds 65C forced air ventilation will be required in order to prevent unit from excessive thermal stress for long period of times 12V output max current charts Input V 12V rail current Input V 12V rail current 6V 6A 11V 12A 7V 7A 12V 12A 15A peak 8V 8A 14V 12A 15A peak 9V 9A 14 18V 12A 15A peak 10V 10A 20 32V 10A ...