background image

13.

glossary of terms

www.minelab.com

p25

Camlock

Lever that releases or locks detector’s assembly components. 

Conductivity

A measure of the ability of a target to allow eddy currents induced 

by the transmitter.

Control box

Encloses the electronic components necessary to generate and interpret 

signals and provide user access to functions via the control panel.

Control buttons

Buttons on the control panel that offer quick access to the functions 

and settings most likely to be used during detector operation 

e.g. PINPOINT and ACCEPT/REJECT.

Control panel

Houses the display screen and provides press-button access to all of 

the detector’s operating functions.

Discrimination

The ability of a metal detector to identify the user’s desired target and 

eliminate signals from undesirable material. 

Ferrous

Composed of or containing iron. Ferrous objects (e.g. nails) are usually 

not desired by the detectorist.

Full Band Spectrum  Simultaneous transmission ranging from 1.5kHz to 100 kHz.
(FBS)

This range in frequencies means that the signal received from the detector 

coil is analyzed from a wide range of responses.

Ground compensationThe ability of the detector to compensate for the effects of

ground mineralization.

Handle assembly

Part of the detector made up of the control box, handle and armrest.

Mineralized ground Ground containing certain minerals, which can cause false signals 

to be given. 

Nickel Metal Hydride NiMH batteries have a longer life span and are not affected by 

(NiMH)

memory to the same degree as some other rechargeable batteries.

Non-ferrous

Not containing iron. Non-ferrous objects or non-magnetic metals 

(such as silver or copper coins, gold jewelry, etc).

Pinpoint

Function allowing an object to be precisely located. PINPOINT 

overrides the automatic motion detection and discrimination 

settings of the Quattro MP. 

Response

The signal or audible indication of a target. 

Search coil

The search coil is the circular plate swept across the ground surface

during detecting. It transmits signals into the ground and receives 

the response.

Sensitivity

The detector’s level of response to a target in the presence of ground 

noise and/or electromagnetic disturbance.

Shaft assembly

An adjustable assembly made up of the upper and lower shaft 

connected by camlocks. The shaft assembly connects the search 

coil to the handle assembly.

Threshold (hum)

The audible level of sound emitted when no target is detected 

is the THRESHOLD. This threshold hum is the background sound made as 

the Quattro MP operates. THRESHOLD can be set anywhere between 

no sound (silent) and loud.

Содержание Quattro MP

Страница 1: ...MINELAB User Manual...

Страница 2: ...tains Minelab Electronics Pty Ltd rights technical data or restricted rights data or both Patents and trademarks apply Disclaimer The Minelab metal detector discussed in this operating manual has been...

Страница 3: ...ly 6 Step 3 Connecting the Shaft Assembly 7 Step 4 Armrest Assembly 7 3 SEARCH COILS 8 4 BATTERIES 9 4 1 Removal Replacement of Battery Pack 9 4 3 Recharging NiMH Battery Pack 10 4 4 Battery Indicator...

Страница 4: ...th Consistent sensitivity over a wide range of targets Circuitry that reduces interference from electromagnetic sources More accurate identification of target characteristics The Full Band Spectrum FB...

Страница 5: ...tteries Coil 10 5 inch 264mm Audio Output Internal speaker or headphones Headphone Input 1 4 inch 6 3mm stereo jack Transmission Full Band Spectrum Simultaneous multiple frequency transmission ranging...

Страница 6: ...h coil itself as this cable is direct wired into the coil and is not dismountable Any attempt to disconnect this cable will void your coil warranty Step 2 Shaft Assembly 1 Release the shaft camlock le...

Страница 7: ...in mind it will need to be parallel to the ground during detecting Note To avoid difficulty securing the control box camlock lever step 9 ensure the shaft camlock is released to allow greater shaft m...

Страница 8: ...To replace the search coil 1 Undo control box camlock and disconnect the coil cable from the control box 2 Separate the two shaft assemblies by releasing the shaft camlock and sliding the lower shaft...

Страница 9: ...full performance There is no limit to the time the battery pack can be left on charge Removal instructions apply to both types of battery packs 4 1 Removal Replacement of Battery Pack To Remove the B...

Страница 10: ...t 18 hours for a complete charge If the battery was not completely discharged the charging time will be shorter The car charger is provided with a 3AG 2Amp fast fuse for short circuit protection which...

Страница 11: ...mmend a comfortable feeling headphone with a high 32 ohm rating Minelab s Custom Koss headphones available as an accessory are rated at 100 ohm 6 Quick Start Simply turn on the Quattro MP by pressing...

Страница 12: ...r in the Factory Preset mode recommended in your first few outings press and hold the POWER button approximately 5 seconds until the Factory Preset message is displayed on the screen 7 2 Display Meter...

Страница 13: ...ds to the ID number E see below shown in the meter 7 2 3 ID Number When a target is detected while searching a number E appears on the left side of the meter identifying the characteristics of the tar...

Страница 14: ...cribed by the detect mode name The four detect modes are Coin 3a Relic 3c Coin Jewelry 3b All Metal 3d In some locations there may be a specific pattern to the type of targets found in the area For ex...

Страница 15: ...ted The audio signal response will vary depending on conductiv ity in the same fashion as the COIN mode The pre set reject settings for this mode are 10 to 1 Tip Low tone Low Conductivity content High...

Страница 16: ...screen as the coil passes directly over the target There is not a lot of difference between the signal produced by shallow targets and those by deeper targets so it is important to note the approximat...

Страница 17: ...ghlighted To avoid pressing the buttons numerous times you can press and hold in the button and the selection will move smoothly then release the button when you ve reached your desired selection c Pr...

Страница 18: ...e Quattro MP The range of volume available is from 0 to 20 and the preset level is 20 This is used to prevent signals from large and shallow items producing very loud signals that are uncomfortable to...

Страница 19: ...jects are moved in close proximity to the search coil 8 5 Contrast The contrast of the main screen can be adjusted using the CONTRAST Control to suit the user as well as weather conditions 8 6 Trash D...

Страница 20: ...et is fully rejected For this reason accurate discrimination is best when operating in LOW setting TIP When detecting do not wear steel toed boots or shoes with metal eyelets These can send conflictin...

Страница 21: ...f a factory pre set mode can be modified and saved as a personal setting so that your own preferred discrimination pattern is ready for use any time you wish The icon will be displayed on the screen t...

Страница 22: ...lost if you select a different detect mode The modified discrimination pattern can be saved as a user detect mode by following the steps below To create and save a user mode The icon will appear next...

Страница 23: ...tent the tone of the signal will be of a higher tone Null If you pass across a target which is discriminated out you will notice that the threshold will momentarily go quiet and return again once you...

Страница 24: ...in the headphones check the headphones and their connection Check the Audio menu s Max Limit a setting of 0 is silent or Audio OFF If there is no sound from the speaker or the headphones but the detec...

Страница 25: ...ts of ground mineralization Handle assembly Part of the detector made up of the control box handle and armrest Mineralized ground Ground containing certain minerals which can cause false signals to be...

Страница 26: ...tivity Preset Auto Target Volume Preset 20 Threshold Preset 12 Noise Cancel Automatic Contrast Preset 10 Trash Density Preset Low Discrimination Settings Coin Mode 10 to 2 and 6 to 8 Coin Jewelry Mode...

Страница 27: ...n environmentally safe manner Disposal of unwanted electronic equipment in landfilled waste may contribute to adverse long term environmental effect due to the leaching of contaminating and toxic subs...

Страница 28: ...notes p28 www minelab com...

Страница 29: ...usa com tel 1 702 891 8809 Minelab Electronics Pty Ltd PO Box 537 Torrensville Plaza South Australia 5031 AUSTRALIA email minelab minelab com au tel 61 8 8238 0888 Minelab International Limited Laragh...

Отзывы: