![Minelab GPX 4800 Скачать руководство пользователя страница 37](http://html1.mh-extra.com/html/minelab/gpx-4800/gpx-4800_instruction-manual_1801289037.webp)
35
GPX 5000 Range
GPX 4800 Range
Factory Preset
Normal, Enhance, Sens Smooth, Fine Gold, Sens Extra, Salt/Gold, Sharp, Coin/Relic
Normal, Enhance, Sens Extra, Sharp, Coin/Relic, Salt-Coarse
Special: Fine Gold (GPX 5000); Sens Extra (GPX 4800)
Soil/Timings
Optimising the detector for different soil
and target types.
The GPX Series Timings define the characteristics of the
Transmitter (Tx) and Receiver (Rx). The Soil/Timings switch
allows you to choose from a range of different Timings. This
optimises the detector for different soil conditions, the type
of coil being used and desired target sizes. Soil/Timings can
make a big improvement to your finds.
Certain Timings have a particular affinity to certain soil
conditions (magnetic, alkaline, neutral, etc.) and on different
target sizes and conductivities. By using the Soil/Timings
switch, changes to the timings can be made to improve the
performance in different conditions.
Normal
Normal gives you the best performance on a wide range of
soil conditions, and it will provide the best depth on a wide
variety of target sizes. It works particularly well with Double D
coils for general detecting. You should always use Normal in
new areas where you are unsure of the soil mineralisation and
the depth/size of targets.
Enhance
The Enhance timing is very effective at cancelling most
ground noise signals, and significantly reduces the response
on hot-rocks. It works very well with monoloop coils in all but
the most extreme soil conditions. It is very sensitive to a range
of target sizes.
Special
Special (p. 57)
is the switch position for selecting one of
the extra Timings available through the LCD menu. You
can choose between Sensitive Extra, Sharp, Coin/Relic and
Salt-Coarse (GPX 4800 only) for the GPX 4800; plus Fine Gold,
Smooth and Salt/Gold for the GPX 5000.
Note:
When switching
between Soil/Timings, there
is a one second pause before
detection continues.
Always remember to re-Ground Balance the detector after
making any changes to the Soil/Timings switch.