background image

User’s Manual

GP 3500

Minelab USA
871 Grier Drive, Suite B1 
Las Vegas, Nevada  89119 
UNITED STATES OF AMERICA 
email: [email protected]
tel: +1-702-891 8809

Minelab Electronics Pty Ltd
PO Box 537  Torrensville Plaza
South Australia  5031  
AUSTRALIA
email: [email protected]
tel: +61-8-8238 0888

Minelab International Limited
Laragh, Bandon 
Co. Cork 
IRELAND
email: [email protected]
tel: +353-23 52101

Contact Details:

www.minelab.com

MINELAB

MINELAB

Содержание GP 3500

Страница 1: ...minelabusa com tel 1 702 891 8809 Minelab Electronics Pty Ltd PO Box 537 Torrensville Plaza South Australia 5031 AUSTRALIA email minelab minelab com au tel 61 8 8238 0888 Minelab International Limited...

Страница 2: ...f care and consideration is taken during and after the removal of targets especially with respect to the back filling of holes this should ensure the continued access to areas for prospecting and trea...

Страница 3: ...ence 11 Quick start instructions easy reference 12 Rear control functions rear panel 13 Front control functions front panel 20 table of contents l contents l page iii GP 3500 page iii GP 3500 www mine...

Страница 4: ...inelab com introducing the Minelab GP 3500 l 1 introduction l page 1 The Minelab GP 3500 utilises Dual Voltage Technology DVT which assists accurate ground balance and increases sensitivity by overcom...

Страница 5: ...ly 8 Upper Shaft 9 Handle with Quick Trak push button 10 Control Box 11 Armrest Parts 2 12 Nylon Bolt 2 13 Nylon Nut 2 14 Arm Straps 2 15 Armrest Cover C Headphones 16 Headphones D Battery and Battery...

Страница 6: ...ete assembly instructions continued l 2 assembly l page 5 GP 3500 GP 3500 www minelab com page 5 Assembling the lower and upper shaft sections Refer Figure 2 2 Step 1 Slide the lower shaft 4 with coil...

Страница 7: ...nuts by hand Step 2 Loop the Quick Trak button cable from the handle back along the shaft and plug it into the Smart Point connection in the control box 10 See page 33 Step 3 Adjust the shaft length...

Страница 8: ...rovide enough power to operate the detector for 14 15 hrs when fully charged The battery may be recharged at any time during the discharge cycle It is very important to fully charge the battery before...

Страница 9: ...ehicles which have a negative earth electrical system Most cars manufactured after 1970 should have negative earth electrical system Connecting the charger to a vehicle with a positive earth system wi...

Страница 10: ...til finished sequence Step 12 Tuning takes approximately 60 seconds A series of 3 beeps will indicate that the optimum frequency has been selected Do not move the detector during the tuning process St...

Страница 11: ...very soft signals An example of this would be to hear a whisper within a crowded noisy room If the threshold level is set too low there is no audible background signal and small target signals will n...

Страница 12: ...ume alone Interpretation of the target signals involves understanding the difference between the rising and falling tone and volume of the threshold in response to different targets The Signal control...

Страница 13: ...t switch provided that they have loudness limiters built in This prevents loud signals becoming unpleasant or dangerous to the user s hearing Figure 4 14 Boost switch rear controls continued l 4 contr...

Страница 14: ...try see page 33 Quick Trak reset button for more details 2 It is a diagnostic test port that ensures that your detector is operating at peak performance before it leaves the factory Smart Point also a...

Страница 15: ...rol is turned further clockwise the operator it able to influence the recognition of a target being ferrous or non ferrous metal Figure 4 18 All Metal Iron Discriminate switch page 22 l 4 controls and...

Страница 16: ...l page 25 GP 3500 Discrimination continued Keeping the control anti clockwise requires a slightly stronger signal before discrimination occurs rotating it clockwise means that discrimination will occ...

Страница 17: ...ose to the coil Cancel changes the electromagnetic field of the coil so that it is particularly stable in areas of electrical interference This position is ideal in areas where the operator wants to d...

Страница 18: ...Fixed to continue detecting once this button is released When the ground is variable in mineral content requiring repeated re balancing use Tracking as the detector continuously tests the ground and...

Страница 19: ...or variable search in Tracking mode To search in Tracking mode switch the Fixed Tracking switch on the control box into Tracking position In this position the detector is continuously testing and re...

Страница 20: ...utton which allows easy operation of ground balancing The Quick Trak push button has two functions depending on where the balance switch is set on the control box If set to Fixed mode If the Balance s...

Страница 21: ...g should be done initially with the Coil switch in Double D or in M Mono If the interference is still severe after completing the tuning operation change the Coil switch to Cancel and then re tune the...

Страница 22: ...ntrol rapidly to move to the desired end you want you will notice noise caused by the rapid movement through the frequencies This is normal and will not be present when the control is turned slowly Th...

Страница 23: ...often only present in one direction In some goldfields a response may be received from a concentration of orange reddish dyke material or clay Remember a metal target will get louder by getting the c...

Страница 24: ...m a deeply buried metallic target Better to ground balance around the target without going across it then switch to Fixed and try Pinpointing identifying target signals continued l 5 detecting l page...

Страница 25: ...d pass over the coil NOTE Your hands and wrists must be free of any metallic jewellery and watches Step 11 If there is no signal place the handful carefully in a new pile and repeat with another handf...

Страница 26: ...to return your detector to Minelab for service please supply as many details as possible about the fault This will enable our service engineers to rectify the fault quickly and efficiently Return the...

Страница 27: ...unauthorised service For specific details of the Minelab warranty please refer to the Product Warranty card It is the responsibility of the owner to pay all transport costs for the detector to Minelab...

Страница 28: ...ntinually compensates for changes in the ground mineralization glossary of common terms page 48 l 6 user info l page 48 GP 3500 Halo Effect After a metal object has remained undisturbed in the soil fo...

Страница 29: ...lses sent into the ground by the coil detector care and safety l 6 user info l page 51 GP 3500 GP 3500 www minelab com page 51 take care The GP 3500 is a high quality electronic instrument It has been...

Страница 30: ...e equipment to be disposed of in an environmentally safe manner Working for a Cleaner Greener Future Disposal of unwanted electronic equipment in landfilled waste may contribute to adverse long term e...

Отзывы: