background image

User Handbook Memor2000

11

Problem

The application program has
frozen or is behaving strangely.

It is impossible to switch on
the hand-held computer.

Communication via the DS-S
doesn’t work.

Action

Restart the program by opening
and then closing the battery
comparment cover.

Check that the batteries are new
and correctly inserted.

Check that the Memor2000 is
correctly placed in the DS-S, i.e.
that the computer rests against the
stops in the DS-S.

5. Troubleshooting

Содержание Memor2000

Страница 1: ...Memor2000 User Handbook...

Страница 2: ...d held computer We recommend that you read it carefully In addition to this handbook you will normally have a separate description of your particular application program We are certain you will find y...

Страница 3: ...diate radio frequency energy and if not installed and used in accordance with the instructions maycause harmful interference to radio communications However there is no guarantee that interference wil...

Страница 4: ...of the hand held computer The Memor2000 has an LCD Supertwist display which means you never have to set the contrast The characters on the screen can be clearly read in all light conditions and from a...

Страница 5: ...n sensitive calculations In this event wait until the calculation has been completed after which it will be possible to switch off the hand held computer again as normal See also New features on page...

Страница 6: ...result An exchangeable peripheral module is fitted at the top of the handle behind the display This special feature of the Memor2000 is described on the next page New features in program update 2 21 C...

Страница 7: ...port for connection via a cable to a PC computer printer barcode readers modem etc IBW module Abbreviation of Integrated Barcode Wand An extension of the COM module In addition to the port this module...

Страница 8: ...d computer However there is no risk that data or programs will be lost When the main batteries are flat a built in back up battery automatically ensures there is no loss of memory Battery replacement...

Страница 9: ...printers such as the Kyoline MTP640 Extech or PENPLUS are available as accessories 3 Accessories You may have ordered some of the following accessories together with your Memor2000 PC connection cabl...

Страница 10: ...nics or battery or deform plastic parts Low temperatures cause condensation when the hand held computer warms up to normal tempera ture which in turn can damage the electronics Don t attempt to take t...

Страница 11: ...and held computer Communication via the DS S doesn t work Action Restart the program by opening and then closing the battery comparment cover Check that the batteries are new and correctly inserted Ch...

Страница 12: ...ogrammable frequency and duration Clock Real time clock with alarm feature Input Output Built in IR link serial channel COM1 normally 19 200 BPS for connection to Docking Station MiniDIN 8 pin connect...

Страница 13: ...nimum Print Contrast 25 absolute dark light reflectance at 670 nm Orientational Tolerance Pitch 55 minimum Skew 65 minimum Specular Dead Zone 2 Size and Weight L 186 mm H 27 mm H 38 mm display W 52 mm...

Страница 14: ...on The appearance of the module also varies See section 1 Application Modules Infrared IR communication Communication where data is transferred as short pulses of infrared light Infrared light is invi...

Страница 15: ...ccess to the system settings These functions should be operated by the system manager To enter the system menu Restart the computer by opening and then closing the battery compartment cover Press the...

Страница 16: ...oftware Battery type Either Alkaline or NiMH can be selected If NiMH has been selected the battery low warning is given at a lower voltage Power on mode 4 There are three alternative ways to switch on...

Страница 17: ...nu have been changed slightly to facilitate settings that depend on the type of module fitted The label on each module indicates the setting to select Module type 4 is the setting for laser scanner SE...

Страница 18: ...tructed line of sight is required between the Ir windows of the different units Ir windows also have a limited angle of vision about 30 so it s important to site the units correctly Best results are a...

Отзывы: