3.3.3
Adjusting the built-in lift-off protection
1.
Alternately turn the threaded bolt (4) downwards at the hex and turn the screw (2)
upwards to avoid jamming/wedging the upper plate (1).
2.
Turn the threaded bolt (4) downwards until the load cell is loaded.
3.
Turn the screw (2) upwards until the safety distance "A" of 1.5–2.5 mm has been
established between the washer (9) and retaining plate (3).
4. Secure the screw (2) with the nut (8).