Example:
Platform with 6-wire connection
+
Meas.
–
Meas.
+
S
upply
+
S
ense
–
S
ense
–
S
upply
P
R
5500
M+ M
–
V+ S
+
S
–
V
–
black
blue
green
gray
red
whit
e
1
2
2
3
1
①
Screen
②
Grounding terminal or screen clamping rail
③
Equipotential bonding conductor
4.5.5
PR 5500/12 digital inputs and outputs
The plug-in card has 4 passive opto-decoupled inputs for process control.
The plug-in card also has 4 relay outputs with potential-free change-over contacts for
process control.
The card is inserted in the option 1/FB and/or option 2 slot.
A maximum of 2 PR 5500/12 plug-in cards can be installed.
4 Device installation
Process Controller Maxxis 4 PR 5500
Minebea Intec
EN-61