Note:
-
The zero tracking does not work when the setting either of coeicient of the zero
tracking data width or the zero tracking time is [0].
-
Do not use the zero tracking when the weight vibrates gradually in near zero point.
-
Note that zero tracking might become efective even if the actual load change is
rapid when the weight change becomes gradually by the strength of the digital ilter
or the stabilization ilter,
-
The zero tracking does not accept when the zero for the efective portion is
compensated by the zero tracking or the zero setting.
9.10 Tare weight cancellation
By selecting [TARE], the weight display value displays the net weight value. And at the
same time, the sign of [GROSS] on status display-1 switches to [NET], the sign of [TARE]
lights, and the display becomes zero.
Tap [TARE] when the gross value is zero to clear the tare weight cancellation.
The tare weight cancellation is cleared, and the display becomes gross amount display. At
the same time, [NET] of status display-1 switches to [GROSS], and the sign of [TARE] turns
of.
9.10.1
Operational condition of tare weight cancellation (OPERATION OF TARE)
The operational condition of tare weight cancellation is selectable from [IN STABLE
MODE] or [ANYTIME].
[ANYTIME] is selected as default.
When [ANYTIME] is selected, the condition becomes that the tare weight cancellation is
anytime acceptable.
And when [IN STABLE MODE] is selected, the tare weight cancellation is acceptable only
when the sign of [STABLE] in status display-1 lights.
9.10.2 Operational range of tare weight cancellation (RANGE OF TARE)
The operational range of tare weight cancellation is selectable from [0 < GROSS
≦
MAX.WEIGHT] or [GROSS
≦
?MAX.WEIGHT?]
[0 < GROSS
≦
MAX.WEIGHT] is selected as default.
Note:
The error of [Z.ERR A/Z] is displayed when the tare weight cancellation is executed out
of range.
Tap [ERR. RESET ] on top left corner in the screen to cancel the error.
9.11 Preset tare
This is a function to display the amount after subtracting the setting value from the gross
weight value.
9.11.1
Operation of preset tare (OPERATION OF PRE.TARE)
The operation of the preset tare is selectable from [EFFECTIVE] or [INVALID].
Weight Controller CSD-918
9 Basic function setting display (BASIC FUNCTION)
EN-80
Minebea Intec
Содержание CSD-918 Series