6.3 Weighing calibration procedure
6.3.1
Flow of weighing calibration
Step 1 Connection with load
cell
Connect this unit with a load cell.
Step 2 Energizing power
supply
Turn on the power supply.
Step 3 Change weighing ca-
libration screen
Change the screen to weighing calibration mode.
Step 4 Set excitation voltage
Set the bridge power supply (load cell excitation).
Step 5 Energizing for 10 min
To stabilize the unit and the load cell, put this unit in-
to the status of energizing for about 10 min.
Step 6 Set scale interval (Mi-
nimum scale)
see Chapter
Set the minimum unit of weighing.
Step 7 Set max. load (Max)
see Chapter
Set the maximum load (Max) that can be weighed by
the load cell.
Step 8 Calibration of zero
see Chapter
Calibrate the zero point by the condition of no load
at the load cell, or by setting the output voltage of
zero of the load cell.
Step 9 Calibration of SPAN
see Chapter
Calibrate the SPAN point by the condition of putting
the weight on the load cell, or by setting the output
voltage for the load cell SPAN.
Step 10 Finish the calibration
Finish the calibration.
Execute the following steps, if necessary.
see Chapter
Step 11 Fine calibration at zero and SPAN
Step 12 Conirmation and registration of pitch
Step 13 Digital linearization
Step 14 Position of decimal point
Step 15 Display condition of [OL]
Step 16 Unit
Step 17 Compensation of gravitational acceleration
6 Calibration
Weight Controller CSD-918
Minebea Intec
EN-41
Содержание CSD-918 Series
Страница 239: ......