Example 3: When an error occurs
ON
DATA
POL.
OVER
ON
ON
P. C.
Note:
When P.C., DATA and POL. are all output, the output transistor switch turns ON
(negative logic). When ERROR is output, all DATA and POL. output transistors turn OFF
(positive logic).
Example 4: When the HOLD signal is input
ON
DATA
POL.
P. C.
ON
ON
HOLD
Note:
-
In this case, HOLD signal input operation is executed after a bridge of 100 ms or
more.
-
When the HOLD signal is input, the P.C. output transistor turns OFF (positive logic).
The P.C. HOLD signal turns OFF after one-shot operation.
18.2.10 Output condition
Output logic set-
ting
Output data
Transistor state Pin-to-COM level when an
external voltage is applied
Yes
ON
L
Negative logic
No
OFF
H
Yes
OFF
H
Positive logic
No
ON
L
18.3 RS-232C and RS-422/485 interface
18.3.1
RS-232C interface speciication (P/N: CSD-903-P74)
Item
Speciication
Communication method Half duplex