MindWare Technologies MindWare Mobile Скачать руководство пользователя страница 3

Start-up:

1. 

Before use, make sure the device is fully charged using the 

medical-grade power supply 

  

 

 

included with your device. From completely discharged, the battery will take 4 hours to fast-   

 

charge mostly full and trickle until complete. Status of charge is reflected on screen by the  

 

 

following symbols:

2. 

To power on the device, click the 

“Run”

           button

3. 

Once the device has booted you have the option of two data 

 

collection modes, 

Local

 and 

WiFi. 

The device can also be 

 

shutdown by choosing the 

“Shutdown”

 tab with the left

 context 

 

button 

A”

.

 

 

4. 

Select method of data collection by using the arrow keys to move 

 

the outline around the Local or WiFi symbol and either clicking the 

 

“Run”

 or 

right context button “B”

, to finalize selection.

Local Mode:

 

Local mode stores data locally on any standard SD card inserted into the device. The 

device includes an SD card, but any other compatible SD card can also be used (SDHC cards are 

recommended). Data collected to SD card can be transferred to any computer with MindWare BioLab 

software installed for analysis. 

1. 

Make sure that a compatible SD card is inserted into the device before attempting to acquire    

 

data. It is suggested to check for available space on the card before beginning data collection to  

 

assure required space is available.

2. 

Check device and local mode settings by selecting the 

“Menu”

 tab with the 

right context button  

 

“B”.

Charging                          Charge Complete

02

Содержание MindWare Mobile

Страница 1: ...Impedance Cardiograph WWW MINDWARETECH COM M a n u a l Product Manual Customer Support Email support mindwaretech com Phone 888 765 9735 ...

Страница 2: ...ort Email support mindwaretech com Phone 614 626 4888 US Toll Free 888 765 9735 Fax 614 626 4915 Contents Product Overview p 01 Start up p 02 Local Mode p 02 04 Bio channel Scaling p 03 WiFi Mode p 04 06 Configuring BioLab p 06 Other Important Features p 06 Important Information Safety p 07 08 01 ...

Страница 3: ...o move the outline around the Local or WiFi symbol and either clicking the Run or right context button B to finalize selection Local Mode Local mode stores data locally on any standard SD card inserted into the device The device includes an SD card but any other compatible SD card can also be used SDHC cards are recommended Data collected to SD card can be transferred to any computer with MindWare...

Страница 4: ... and off by selecting the channel and using the Left and Right arrow keys to change between on and off 8 The gain of certain channels can also be edited by choosing the channel and using the Left and Right arrow keys on the Gain line found below On Off option See Bio channel scaling table below 9 It is important to note that on the right side of the Acquisition Settings screen an up or down arrow ...

Страница 5: ... tab 17 At this point data is being recorded to the SD card Do not remove SD card during acquisition 16 During Acquisition controls have been locked To unlock them hold both the Left and Right arrow keys simultaneously 17 When controls are unlocked signals can be viewed Ending acquisition can be done on this screen by selecting the Exit tab All result will be saved to SD card WiFi Mode Wifi Mode a...

Страница 6: ...k overview that the device is now using status will read Not Connected 9 Return to the main menu by selecting the Menu tab with the right context button B 10 From the Main Menu Screen select System Settings This screen contains Device Name Date Time as well as the About option 11 Selecting Device Name will bring up the option to edit the device name as it appears on the network Edit by using the a...

Страница 7: ... device is now reading signals It is a good idea to preview the signals in BioLab before beginning data collection 21 During Acquisition controls have been locked To unlock them hold both the Left and Right arrow keys simultaneously 22 When controls are unlocked acquisition can be ended by selecting the End tab However it is recommended to control the acquisition from BioLab Other Important featur...

Страница 8: ...SS standard s Operation is subject to the following two conditions 1 This device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device Within the band 5150 5250 MHz the operation of this device is restricted to indoor use to reduce the potential for harmful interference to co channel mobile satellite system...

Страница 9: ... or application designer Any use or application of MindWare Technologies LTD products for or involving medical or clinical treatment must be performed by properly trained and qualified medical personnel and all traditional medical safeguards equipment and procedures that are appropriate in the particular situation to prevent serious injury or death should always continue to be used when MindWare T...

Отзывы: