background image

                                                                                                               

*

内部资料

*       

本文档中包含的信息涉及深圳迈瑞生物医疗电子股份有限公司秘密,均为内部保密信息,未经许可,不得外发。 

 

FCC Radiation Exposure Statement: 

 

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. End 

users must follow the specific operating instructions for satisfying RF exposure compliance. 

 

This  module  certified  that  complies  with  RF  exposure  requirement  under  mobile  or  fixed  condition,  this 

module is to be installed only in mobile or fixed applications. 

 

A  mobile  device  is  defined  as  a  transmitting  device  designed  to  be  used  in  other  than  fixed  locations  and  to 

generally  be  used  in  such  a  way  that  a  separation  distance  of  at  least  20  centimeters  is  normally  maintained 

between  the  transmitter's  radiating  structure(s)  and  the  body  of  the  user  or  nearby  persons.  Transmitting 

devices  designed  to be  used by  consumers  or  workers that  can  be  easily re-located,  such as  wireless devices 

associated  with  a  personal  computer,  are  considered  to  be  mobile  devices  if  they  meet  the  20  centimeter 

separation requirement. 

 

A fixed device is defined as a device is physically secured at one location and is not able to be easily moved to 

another location. 

 

Note 2: 

Any modifications made to the module will void the Grant of Certification, this module is limited to 

OEM  installation  only  and  must  not  be  sold  to  end-users,  end-user  has  no  manual  instructions  to  remove  or 

install  the  device,  only  software  or  operating  procedure  shall  be  placed  in  the  end-user  operating  manual  of 

final products. 

 

Note 3:

 Additional testing and certification may be necessary when multiple modules are used. 

 

Note 4: 

The module may be operated only with the antenna with which it is authorized. Any antenna that is of 

the same type and of equal or less directional gain as an antenna that is authorized with the intentional radiator 

may be marketed with, and used with, that intentional radiator. 

 

Note  5:

  To  ensure  compliance  with  all  non-transmitter  functions  the  host  manufacturer  is  responsible  for 

ensuring compliance with the module(s) installed and fully operational. For example, if a host was previously 

authorized  as  an  unintentional  radiator  under  the  Supplier’s  Declaration  of  Conformity  procedure  without  a 

transmitter certified module and a module is added, the host manufacturer is responsible for ensuring that the 

after the module is installed and operational the host continues to be compliant with the Part 15B unintentional 

radiator  requirements.  Since  this  may  depend  on  the  details  of  how  the  module  is  integrated  with  the  host, 

SHENZHEN  MINDRAY  BIO-MEDICAL  ELECTRONICS  CO.,  LTD.  shall  provide  guidance  to  the  host 

manufacturer for compliance with the Part 15B requirements. 

 

Note  6:

  FCC  ID  label  on  the  final  system  must  be  labeled  with  “Contains  FCC  ID:  ZLZ-WLINK”  or 

“Contains transmitter module FCC ID: ZLZ-WLINK”. 

 

Содержание LBWA1UZ1GC-958

Страница 1: ...for the host mcu Wlink PCBA is shown as follows The block diagram of Wlink PCBA is as follows based on Murata s LBWA1UZ1GC 958 module whose core chip is Cypress s CYW43907 VDD UART JTAG GPIO SPI RST I PEX LBWA1UZ1GC 958 802 11a b g n Module LPF Match Crystal 32 768kHz Flash MX25L6433FZ2I 08G SDIO ANT DIV ANT OUT DIV ANT CTRL 1 2 application scenario Wlink PCBA is integrated into the internal mothe...

Страница 2: ...息 未经许可 不得外发 antenna is connected to the I pex socket MHF I on the module through a RF cable Wlink is suitable for products that do not require high WiFi throughput or need to achieve WiFi function isolation such as pumps AEDs defibrillation etc ...

Страница 3: ...t the lowest datarate 11a 6Mbps 90dBm 11b 1Mbps 92dBm 11g 6Mbps 90dBm 11n MCS0 90dBm ANT port One Ipex MHF I connector Communicating port UART Power port 3 13V 3 6V Frequency range 2412MHz 2462MHz 5180MHz 5320MHz 5500MHz 5700MHz 5745MHz 5825MHz datarate IEEE 802 11a 6 54 Mbps IEEE 802 11b 1 11 Mbps IEEE 802 11g 6 54 Mbps IEEE 802 11n MCS0 MCS7 support HT20 and HT40 when at 5Ghz band security stand...

Страница 4: ...TMS 11 GPIO_6_JTAG_TRST_L I JTAG TRST 12 HIB_REG_ON_IN I Reset in 13 VDD Power power typically 3 3VDC 14 GND A GND 15 GND A GND 16 RF_SW_CTRL_8_UART2_RX I Dubug uart input 17 RF_SW_CTRL_9_HIB_LPO_SEL_UART2_TX O Dubug uart output 18 SDIO_DATA1 I O SDIO DATA 19 SDIO_DATA0 I O SDIO DATA 20 SDIO_CMD I O SDIO CMD 21 SDIO_CLK I SDIO CLK 22 GND A GND 23 GND A GND 24 WAKE_OUT O WAKE UP OUTPUT 25 WAKE_IN I...

Страница 5: ...serial communication timing requirements are as follows WKUP TXRDY TXD RXD Sleep WKUP and TXD are the output signals of the upper computer After WKUP changes from high to low TXRDY signal must respond to the low level of T2 length within T1 time After that the host computer sends serial port commands Before Wifi module sends serial data it needs to drive TXRDY signal to low 1 3 power Wlink works w...

Страница 6: ... 内部资料 本文档中包含的信息涉及深圳迈瑞生物医疗电子股份有限公司秘密 均为内部保密信息 未经许可 不得外发 ...

Страница 7: ...d layout 1 The right half of Wlink is an analog circuit with antenna interface and diversity antenna circuit as shown in the figure below Avoid running high speed clock lines on the carrier board near the Wlink analog circuit Grounding is recommended 2 There are test points on the bottom of Wlink and the surface of the carrier board should avoid the risk of short circuit caused by copper opening ...

Страница 8: ...8mm 14 3mm The maximum height without socket is 2 82mm The maximum height with socket is 3 5mm 1 4 other notes 1 When the machine is integrated it is necessary to prevent Wlink from receiving 2 4G 5G electromagnetic interference such as magnetic couple devices CPU DDR 2 4G wifi antenna etc from other part of the machine otherwise it will reduce the radio frequency sensitivity and reduce the commun...

Страница 9: ... received including interference that may cause undesired operation NOTE 1 Any changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment This equipment complies with the FCC RF radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with a ...

Страница 10: ...5G 3 38dBi 50ohm 2 FPC dipole 2 4G 2 79dBi 5G 3 38dBi 50ohm 3 FPC dipole 2 4G 2 6dBi 5G 3 1dBi 50ohm 4 Copper pipe dipole 2 4G 1 32dBi 5G 2 75dBi 50ohm 5 Copper pipe dipole 2 4G 1 87dBi 5G 0 94dBi 50ohm 6 FPC PIFA 2 4G 1dBi 5G 1dBi 50ohm 7 FPC PIFA 2 4G 1 56dBi 5G 4 17dBi 50ohm 2 8 Label and compliance information Remind end customers to add Contain FCC ID ZLZ WLINK 2 9 Information on test modes a...

Страница 11: ...radiator under the Supplier s Declaration of Conformity procedure without a transmitter certified module and a module is added the host manufacturer is responsible for ensuring that the after the module is installed and operational the host continues to be compliant with the Part 15B unintentional radiator requirements Since this may depend on the details of how the module is integrated with the h...

Страница 12: ...ld to end users end user has no manual instructions to remove or install the device only software or operating procedure shall be placed in the end user operating manual of final products Note 3 Additional testing and certification may be necessary when multiple modules are used Note 4 The module may be operated only with the antenna with which it is authorized Any antenna that is of the same type...

Страница 13: ... aux appareils radio exempts de licence L exploitation est autorisée aux deux conditions suivantes 1 L appareil ne doit pas produire de brouillage 2 L appareil doit accepter tout brouillage radioélectrique subi même si le brouillage est susceptible d en compromettre le fonctionnement This radio transmitter enter the device s ISED certification number has been approved by Innovation Science and Eco...

Страница 14: ...ion only and must not be sold to end users end user has no manual instructions to remove or install the device only software or operating procedure shall be placed in the end user operating manual of final products Additional testing and certification may be necessary when multiple modules are used Ce module est limitéàl installation OEM uniquement et ne doit pas ê tre vendu aux utilisateurs finau...

Отзывы: