background image

Unit:mm

We reserve the right to change the specification without prior notice.

PR-0246D   2021/11 Printing

9

6

15.5
22.5

20

20

30

30

37

21.8

Rated pressure range

Withstand pressure
Applicable fluid

k

gf/cm

2

bar
psi

Pressure

resolution

 

Ambient humidity range

Vibration

Shock

Temperature characteristic

Weight

MPa

A. 

SPECIFICATIONS

TYPE

Battery 

Battery life

Low-power indicator
Battery replaceable

Turn-on interval

Sampling rate

Repeatability
Display

Indicator accuracy

B. 

ORDERING INFORMATION

F1 : R1/8", M5

F2 : NPT1/8", #10-32 UNF

F3 : G1/8"(BSPP), M5

F4 : R1/4", M5

F5 : NPT1/4", #10-32 UNF

F6 : G1/4”(BSPP), M5

Optional Parts

C. 

PANEL DESCRIPTION

Battery Meter

Pressure Display

Setting Button

Pressure Unit 

Display Section

D. 

DIMENSIONS

E

BATTERY STATUS / INSTALLATION

F1~F3:Hex flat:12

F4~F6:Hex flat:14

F1 : R1/8", M5

F2 : NPT1/8", #10-32 UNF

F3 : G1/8"(BSPP), M5

F4 : R1/4", M5

F5 : NPT1/4", #10-32 UNF

F6 : G1/4”(BSPP), M5

1

4

7

8

MPa

MPa

6

"+"

"-"

1.5MPa

0.000 ~ 1.000MPa

Filtered air, incombustible and non-corrosive gases

0.01
0.01

0.1

0.001

 Operation/Storage: 35 ~ 85% RH ( No condensation)

Total amplitude 1.5mm or 10G, 10Hz-55Hz-10Hz scan 

for 1 minute, two hours each direction of X, Y and Z

 100m/s

2

 (10G), 3 times each in direction of X, Y and Z

Approx. 40g

Yes
Yes

2 Hz (2 times/sec.)

3 ½ digital, 7 segment LCD display ( Black )

±2% F.S.  ±1 digit  (ambient temperature: 25 ±3 °C)

Operation: 0 ~ 50 ºC, storage: -10 ~ 60 ºC 

( No condensation or freezing)

±2% F.S. of detected pressure (25°C) at temp. 

range of 0~50°C

 

Ambient temp. range

Enclosure

Environment

*1. When the pressure is -0.1MPa, LCD displays           MPa.

*2. Air tube must be installed to maintain IP65. (See section K)

5

2

3

MPG-60

 

Series

For your safety, please read the following before using.

1

2

3

4
5

6

FOLLOW THE STEPS BELOW

 Using a flat screwdriver size 1.4 ~ 3.0 mm insert into the back of the 

   pressure gage as pictured. (See figure     )

● 

Turn the screwdriver horizontally 90° to separate the case and the base. 

   Repeat this process again for the other side. (See figure     )

● C

arefully remove the outer cover (See figure     ), and follow the diagrams 

   below to replace battery and reassembly. Polarity must be observed, 

   incorrect battery installation will cause malfunction.

2

3

4

(Positive)

(Vacuum)

MPG-60V-

MPG-60P-

MPG-60VL-

MPG-60PL-

mmHg

CR 2032 lithium

IP

65

 

*2

Pressure Range

Pressure Port

V : Vacuum (10 ~ -101kPa)

P : Positive (-0.100 ~ 1.000MPa)

0 ~ -101kPa

-0.100 ~ 1.000MPa *1

10 ~ -101kPa

Display pressure range

300kPa

k

Pa

-

-

0.01

0.1

1

1

-

-

Display turn off after 60 sec.

(Vacuum)

(Positive)

psi bar mmHg kPa

psi bar kgf MPa

Port size

F1:R1/8”, M5; F2:NPT1/8”, #10-32 UNF; F3:G1/8”(BSPP), M5

F4:R1/4”, M5; F5:NPT1/4”, #10-32 UNF; F6:G1/4”(BSPP), M5

     3 years 

(5 times/day)

     3 years 

(5 times/day)

     1 year

(5 times/day)

     1 year

(5 times/day)

Pressure unit

psi, bar, kgf/cm

2

 and MPa

 u

ser selectable

psi, bar, mmHg and kPa

 u

ser selectable

Back light

Yes

Yes

No

No

Back Light

Blank : Back light unavailable

L : Back light available

Do not use corrosive or flammable gas or liquid with this product.

Please use within the rated pressure range. Do not apply pressure 

beyond recommended maximum withstand pressure, permanent 

damage to the pressure gage may occur. 

Do not drop, hit or allow excessive shock. Even if press

ure gage 

body

 appears undamaged, internal components may be broken and 

can cause malfunction.

Do not use in environment containing steam or oil vapor.

This product is not explosion-proof rated. Do not use in atmosphere 

containing flammable or explosive gases.

Using filter can extend pressure gage’s service life.

MP-A5 : Mounting bracket (BT-5)

MP-A6 : Mounting bracket (BT-6)

MP-B2 : Panel adapter (PA-C)

MP-C2 : Panel a Front protective lid (PA-D)

±0.2% F.S. ±1digit

±

1

% F.S. ±1digit

M P G - 6 0 P L - F 1

Ø 2mm MAX

Отзывы: