PANEL DESCRIPTION
3 ½ Digit LED Display
Switch (OUT1)
Setting
B
utton
Green LED
Display the measured
pressure value. each setting
mode and error code.
( ) Button
Change setting mode and
pre-set final desired value.
Switch(OUT 2)
Red LED
Use the( ) button to change
setting mode and pre-set
desired value.
OUTPUT CIRCUIT WIRING DIAGRAMS
For your safety, please read the following before using.
Do not use corrosive or flammable gas or liquid with this product.
Please use within the operating pressure range. Do not apply pressure beyond recommended maximum pressure, permanent
damage to the pressure sensor may occur.
Do not drop, hit or allow excessive shock. Even if switch body appears undamaged, internal components may be broken and
can cause malfunction.
Turn power off before connecting wiring. Wrong wiring or short circuit will damage and/or cause malfunction.
Do not use in environment containing steam or oil vapor.
This product is not explosion-proof rated. Do not use in atmosphere containing flammable or explosive gases.
Wiring for pressure sensor should avoid power source line and high voltage line. If use in the same circuit, noise may cause
malfunction.
ORDERING INFORMATION
Use the( ) button to change
setting mode and pre-set
desired value.
-100.0 ~ 100.0kPa
0.0 ~ -101.3kPa
-0.100 ~ 1.000MPa
10.0 ~ -101.3kPa
0.000 ~ 1.000MPa
0.1
0.001
0.001
0
.01
-
0.001
0
.01
0
.01
0.1
-
-
-
1
0.1
0.1
Filtered
Air, Non-corrosive/Non-flammable gases
12 to 24V DC ±10%, Ripple (P-P) 10% or less
≦
60mA
±0.2% F.S. ±1digit
Fixed (3 digits)
≦
2.5ms (chattering-proof function: 24ms, 192ms and 768ms selections)
Yes
3 ½ digit, 7 segment LED display ( Red ) ( Sampling rate : 5 times / sec. )
±2% F.S. ±1 digit (Ambient temperature: 25 ±3°C)
Green Indicator : OUT1 & Red Indicator : OUT2
-100.0 ~ 100.0kPa
(Vacuum)
(Positive)
(Compound)
Operation/Storage: 35 ~ 85% RH (No condensation)
1000V AC in 1-min (between case and lead wire)
IP40
50M
Ω
(at 500V DC, between case and lead wire)
980m/s
2
(100G), 3 times each in direction of X, Y and Z
±2% F.S. of detected pressure (25°C) at temp. Range of 0~50°C
Ø4 Oil-resistance cable ( PVC ) - 26 AWG ( 0.15 mm
2
) - 5 cores ( MP30 □ - 01 / 03 ) ;
Ø4 Oil-resistance cable ( PVC ) - 26 AWG ( 0.15 mm
2
) - 4 cores ( MP30 □ - 02 / 04 )
Operation: 0 ~ 50°C, Storage: -20 ~ 60°C (No condensation or freezing)
Approx. 67g (with 2 meter lead wire), Approx. 35g (with M8 4Pin male connector )
Total amplitude 1.5mm, 10Hz-55Hz-10Hz scan for 1 minute, two hours each direction of X, Y and Z
Adjustable
300kPa
1.5MPa
Output voltage: 1 to 5V ±2.5% F.S.
(within rated pressure range)
Linearity: ±1% F.S.
Output voltage: 1 to 5V
±
5%
F.S.
(within rated pressure range)
Linearity: ±
1
% F.S.
Pressure Range
Output Specifications
C
:
Compound (-100.0~100.0kPa)
V
:
Vacuum (10.0~-101.3kPa)
P
:
Positive (-0.100~1.000MPa)
F1
:
R1/8", M5
F2
:
NPT1/8", M5
F3
:
G1/8”(BSPP), M5
Blank
:
With 2meter cable
QD
:
With M8 4Pin male connector
*(Only type MP30
-02-
, MP30
-04-
)
01
:
2 NPN output & 1 Analog output
02
:
2 NPN output
03
:
2 PNP output & 1 Analog output
04
:
2 PNP output
Cable Length/Connector
Pressure Port
MP30 - 02- -
NPN output
MP30 - 01- -
NPN output & Analog output
S
wit
ch
m
ain
cir
cuit
S
wit
ch
m
ain
cir
cuit
S
wit
ch
m
ain
cir
cuit
S
wit
ch
m
ain
cir
cuit
DC(–) (Blue)
DC(–) (Blue)
DC(–) (Blue)
DC(–) (Blue)
OUT2 (White)
OUT2 (White)
OUT2 (White)
OUT2 (White)
OUT1 (Black)
OUT1 (Black)
OUT1 (Black)
OUT1 (Black)
(Orange)
(Orange)
Analog Output
Analog Output
DC(+) (Brown)
DC(+) (Brown)
DC(+) (Brown)
DC(+) (Brown)
DC
DC
12-24V
DC
12-24V
DC
12-24V
DC
12-24V
1KΩ
MP30 - 04- -
PNP output
MP30 - 03- -
PNP output & Analog output
1KΩ
F1:R1/8", M5
F2:
N
PT1/8", M5
F3: G1/8”(BSPP), M5
F1:R1/8", M5 ; F2:
N
PT1/8", M5 ; F3: G1/8”(BSPP), M5
NPN: open collector 2 outputs
Max. load current: 100mA
Max. supply voltage: 30V DC
Residual voltage:
≦
1V
PNP: open collector 2 outputs
Max. load current: 100mA
Max. supply voltage: 24V DC
Residual voltage:
≦
1V
MP30C- -
MP30V- -
MP30P- -
R
L
R
L
R
L
R
L
DIMENSIONS
ANALOG OUTPUT
Analog output range 1 to 5V, proportional to the pressure range.
(Compound)
Analog output (V)
5
3
1
-100.0
0.0
100.0 (kPa)
(Low)
(High)
( ) Button
1
2
3
4
5
6
7
Unit:mm
Rated pressure range
Setting pressure range
Withstand pressure
Fluid
Power supply voltage
Current consumption
Switch output
Hysteresis mode
Response time
Output short circuit protection
Display
Indicator accuracy
Indicator
kPa
MPa
kgf/cm
2
bar
psi
mm
H
g
inH
g
mmH
2
O
Set pressure
resolution
SPECIFICATIONS
Repeatability(Switch output)
Hysteresis
Window comparator mode
Ambient temp. range
Ambient humidity range
Withstand voltage
Enclosure
Insulation resistance
Vibration
Shock
Temperature characteristic
Port size
Lead wire
Weight
Environment
Analog output
*(Only type MP30
-01-
,
MP30
-03-
)
3
1
4
2
QD PINOUT
PR-0069D 2021/07 Printing We reserve the right to change the specification without prior notice.
R
L
R
L
R
L
R
L
(Vacuum)
Analog output (V)
5
1
0.0
-101.3 (kPa)
(Low)
(High)
(Positive)
Analog output (V)
5
1
0.000
1.000 (MPa)
(Low)
(High)
300
2000
-
MP30
MINDMAN INDUSTRIAL CO., LTD.
M P 3 0 C - 0 1 - F 1 -
www.mindman.com.tw