background image

79 

3-42 String transmission 

Note: The information in this chapter is closely related to the chapter of String setting. 

Format of barcode data transmission: 

Prefix  Code name  Preamble 

Code ID 

Code length 

Code data  Code ID 

Postamble 

Suffix 

Prefix transmission: By setting Enable, prefix will be appended before the data transmitted. 
Suffix transmission: By setting Enable, suffix will be appended after the data is transmitted. 
Code name transmission: By setting Enable, code name will be transmitted before code data. 
Preamble transmission: By setting Enable, preamble will be appended before the data transmitted. 
Postamble transmission: By setting Enable, postamble will be appended after the data is transmitted. 
Code ID transmission: Code ID can be transmitted in the format of either Proprietary ID or AIM ID. Refer 
to 

1-2 Default setting for each barcode

Code length transmission: The length of code data string can be transmitted before the code data when 
Enable is selected. The length is represented by a number with two digits. 
Case conversion: The characters within code data or the whole output string can be set in either upper 
case or lower case. 
FN1  substitution  transmission:  The  image  platform  supports  a  FN1  substitution  feature  for  keyboard 
wedge, USB and RS-232 interface. The replacement string of FN1 can be chosen by user (see 

3-40 

G1-G6 & C1-C3 & FN1 substitution string setting

 

). 

All-non-printable-character string transmission with string setting: By setting enable, all string settings, 
e.g. Preamble transmission or Insert G1 string setting, are active for an all-non-printable-character string. 
Here a non-printable character means a character with ASCII value between 0x00 to 0x1F. 
Transmit the first N data characters only: The image platform supports to only transmit the first N data 
characters of a barcode. The number of N can be set as a digit between 1 and 99. 
Transmit the last N data characters only: The image platform supports to only transmit the last N data 
characters of a barcode. The number of N can be set as a digit between 1 and 99. 

Содержание MP8608

Страница 1: ...MP8608 Image Platform User Manual Version MP8608_UM_EN_V1 1 1...

Страница 2: ......

Страница 3: ...ed to the user is on a licensed basis 2 The right is reserved to make changes to any software or product to improve reliability function or design 3 The material in this manual is subject to change wi...

Страница 4: ...ii...

Страница 5: ...3 3 Interface selection 11 3 4 RS 232 interface 12 3 5 USB interface 14 3 6 Scan mode some global settings 17 3 7 LED and Beeper Indication 22 3 8 LED illumination level 24 3 9 Single type of barcode...

Страница 6: ...e 69 3 37 Data Matrix 70 3 38 Han Xin Code 71 3 39 Aztec Code 72 3 40 G1 G6 C1 C3 FN1 substitution string setting 73 3 41 G1 G4 string position Code ID position 78 3 42 String transmission 79 4 Mainte...

Страница 7: ...Code 39 Interleaved 2 of 5 Industrial 2 of 5 Discrete 2 of 5 Matrix 2 of 5 Codabar NW7 Code 128 UCC EAN 128 GS1 128 ISBT 128 Code 93 Code 11 USD 8 MSI Plessey UK Plessey China Post China Finance GS1 D...

Страница 8: ...odabar 4 N Fm Code 128 1 K Cm UCC EAN 128 GS1 128 1 K Cm ISBT 128 1 K Cm Code 93 1 L Gm Code 11 4 V Hm MSI Plessey 4 O Mm UK Plessey 1 U Mm China Post 11 2 T Im China Finance 10 2 Y GS1 DataBar 16 2 R...

Страница 9: ...auto selection purpose 3 3V for interface auto selection purpose 3 Ground Ground 4 3 3V for interface auto selection purpose Ground for interface auto selection purpose 5 TxD Reserved 6 RxD Reserved...

Страница 10: ...4 2 2 Dimensions Figure 2 2 Dimensions without stand...

Страница 11: ...5 Figure 2 3 Dimensions with stand...

Страница 12: ...6 Figure 2 4 Dimensions of hanging holes...

Страница 13: ...7 2 3 Field of view Figure 2 5 Field of view Front view...

Страница 14: ...e power supply on PIN 9 connect the external power supply 5 V DC adapter to the RS 232 cable 5 Switch on the host If connect properly the beeper and the LED of the image platform will indicate Figure...

Страница 15: ...can the appropriate Single scan setting according to the user s demand Example To set Flow control to be XON XOFF Steps Scan the following barcode Multiple scan setting Step 1 Scan the Option barcode...

Страница 16: ...aracter string with various length of 2 4 or other values Example Set 0401 03 decimal 8002 0D0A hexadecimal 8202 01 decimal The customized QR code barcode contents and symbol are as following 0401D03...

Страница 17: ...an appropriate cable provided by the manufacturer will work for a specific interface Interface selection Auto detection By setting this function the image platform will automatically detect the RS 232...

Страница 18: ...image platform receives an XON character ACK NAK After transmitting data the image platform expects either an ACK acknowledge or NAK not acknowledge response from the host When a NAK is received the...

Страница 19: ...ode Option Alpha entry 80 ms 05 Response delay 00 99 100 ms 00 99 00 Baud rate 300 00 600 01 1200 02 2400 03 4800 04 9600 05 19200 06 38400 07 57600 08 115200 09 Parity bit None 00 Odd 01 Even 02 Data...

Страница 20: ...tform automatically restarts Simple COM Port Emulation Please contact the manufacturer for the instruction Keyboard layout The image platform supports different national keyboard layouts Commonly an a...

Страница 21: ...ple Mac 01 USB virtual COM 02 Simple COM Port Emulation 03 Keyboard layout USA 00 Turkish F 01 Turkish Q 02 French 03 Italian 04 Spanish 05 Slovak 06 Denmark 07 Japanese 08 German 09 Belgian 10 Russia...

Страница 22: ...16 Multiple scan setting Single scan setting Option barcode Option Alpha entry 20 ms 03 40 ms 04 60 ms 05 Numeric key Alphabetic key 00 Numeric keypad 01 Alt keypad 02...

Страница 23: ...time for 2D symbol If a 2D barcode has been scanned and output once successfully the image platform must output the same barcode data beyond delay time When this feature is set to be 0xFF then the de...

Страница 24: ...ill output the data after the predefined delay elapsed The maximum storage of data is 1000 characters If this parameter is set to be 00 the image platform will not store data And if the parameter is s...

Страница 25: ...off 07 Auto detection sensitivity High 00 Low 01 Standby duration 5 seconds 00 10 seconds 01 15 seconds 02 30 seconds 03 1 minute 04 2 minutes 05 3 minutes 06 5 minutes 07 10 minutes 08 15 minutes 09...

Страница 26: ...01 99 01 99 04 Global G1 G6 string selection 00 66 00 66 00 Element amendment Disable 00 Enable 01 Character output restraint None 00 Printable character only 01 Alphanumeric character only 02 Decoder...

Страница 27: ...21 Multiple scan setting Single scan setting Option barcode Option Alpha entry next decode attempt Enable 01...

Страница 28: ...ccessful reading the image platform will beep to indicate a good barcode reading and its beep tone duration is adjustable Beep tone duration This parameter can be adjusted for a good reading upon favo...

Страница 29: ...de Option Alpha entry Power on alert Disable 00 Enable 01 LED indication Disable 00 Enable 01 Beeper indication Disable 00 Enable 01 Beep tone duration 01 09 10 ms 01 09 05 Volume of beeper Low 00 Mid...

Страница 30: ...to the target increases Level of decode illumination This parameter can be adjusted for different level of decode illumination Illumination mode of Auto detection Always off Illumination LED will be a...

Страница 31: ...entry Decode illumination mode Always Off 00 Always On 01 On when reading 03 Level of decode illumination Disable decode illumination 00 Low 01 Middle 02 High 03 Illumination mode of Auto detection A...

Страница 32: ...ols in one image By setting Disable the image platform will only read the symbol closest to the center area in the image Multiple scan setting Single scan setting Option barcode Option Alpha entry 1D...

Страница 33: ...The symbol types which support Structured Append include QR code Aztec code PDF417 and DataMatrix The lower part of below figure shows an example of four Structured Append symbols with the same data...

Страница 34: ...ultiple scan setting Single scan setting Option barcode Option Alpha entry DPM format read Disable 00 Enable 01 Structured append symbols read Disable 00 Enable 01 Mobile screen read Disable 00 Enable...

Страница 35: ...e Supplement digits barcode is the supplemental 2 or 5 characters Format System character Data digits 10 digits Check digit 1 digit Supplement digits 2 or 5 Truncation Expansion Truncate leading zeros...

Страница 36: ...Disable 00 Enable 01 Check digit trans Disable 00 Enable 01 Code ID setting 00 FF16 ASCII 00 FF16 A Insert group selection 00 66 00 66 00 Supplement digits None 00 2 digits 01 5 digits 02 2 or 5 digi...

Страница 37: ...Truncation Expansion Truncate leading zeros The leading 0 digits of UPC E data characters can be truncated when the feature is enabled Example Barcode 00123457 Output 123457 Expand to EAN 13 It extend...

Страница 38: ...0 Enable 01 Check digit trans Disable 00 Enable 01 Code ID setting 00 FF16 ASCII 00 FF16 D Insert group selection 00 66 00 66 00 Supplement digits None 00 2 digits 01 5 digits 02 2 or 5 digits 03 Trun...

Страница 39: ...em character 1 Data digits 6 digits Check digit 1 digit Supplement digits 2 or 5 Truncation Expansion Expand to EAN 13 It extends to 13 digits with 0 digits when the feature is enabled Example Barcode...

Страница 40: ...ion Disable 00 Enable 01 Check digit trans Disable 00 Enable 01 Code ID setting 00 FF16 ASCII 00 FF16 D Insert group selection 00 66 00 66 00 Supplement digits None 00 2 digits 01 5 digits 02 2 or 5 d...

Страница 41: ...to Insertion group selection of 3 11 UPC A Supplement digits Format Data digits 12 digits Check digit 1 digit Supplement digits 2 or 5 ISBN ISSN conversion The ISBN International Standard Book Number...

Страница 42: ...ification Disable 00 Enable 01 Check digit transmission Disable 00 Enable 01 EAN 13 code ID setting 00 FF16 ASCII 00 FF16 A Insert group selection 00 66 00 66 00 Supplement digits None 00 2 digits 01...

Страница 43: ...e data digits Check digit trans By setting Enable check digit will be transmitted Code ID setting Refer to Code ID setting of 3 11 UPC A Insertion group selection Refer to Insertion group selection of...

Страница 44: ...Check digit verification Disable 00 Enable 01 Check digit trans Disable 00 Enable 01 Code ID setting 00 FF16 ASCII 00 FF16 C Insert group selection 00 66 00 66 00 Supplement digits None 00 2 digits 0...

Страница 45: ...ength barcode decoded Code ID setting Refer to Code ID setting of 3 11 UPC A Insertion group selection Refer to Insertion group selection of 3 11 UPC A Start End transmission The start and end charact...

Страница 46: ...le 01 Check digit transmission Disable 00 Enable 01 Max code length 00 99 00 99 00 Min code length 00 99 00 99 01 Code ID setting 00 FF16 ASCII 00 FF16 M Insert group selection 00 66 00 66 00 Format S...

Страница 47: ...ng Single scan setting Option barcode Option Alpha entry Enable 01 Code 32 Prefix A transmission Disable 00 Enable 01 Trioptic Code 39 read Disable 00 Enable 01 Trioptic Code 39 Start End transmission...

Страница 48: ...optional check digit algorithms the specified Uniform Symbol Specification USS and the Optical Product Code Council OPCC Check digit transmission By setting Enable check digit will be transmitted Max...

Страница 49: ...a entry Read Disable 00 Enable 01 Check digit verification Disable 00 USS 01 OPCC 02 Check digit transmission Disable 00 Enable 01 Max code length 00 99 00 99 00 Min code length 00 99 00 99 06 Code ID...

Страница 50: ...e ID setting Refer to Code ID setting of 3 11 UPC A Insertion group selection Refer to Insertion group selection of 3 11 UPC A Multiple scan setting Single scan setting Option barcode Option Alpha ent...

Страница 51: ...length of 3 16 Code 39 Code 32 Trioptic Code 39 Code ID setting Refer to Code ID setting of 3 11 UPC A Insertion group selection Refer to Insertion group selection of 3 11 UPC A Multiple scan setting...

Страница 52: ...Insertion group selection of 3 11 UPC A Start End type Codabar has four pairs of Start End pattern you may select one pair to match your application Start End transmission Refer to Start End transmis...

Страница 53: ...tting Option barcode Option Alpha entry Insert group selection 00 66 00 66 00 Start End type ABCD ABCD 00 abcd abcd 01 ABCD TN E 02 abcd tn e 03 Start End transmission Disable 00 Enable 01 Start End c...

Страница 54: ...n By setting Enable check digit will be transmitted Max Min code length Refer to Max Min code length of 3 16 Code 39 Code 32 Trioptic Code 39 Code ID setting Refer to Code ID setting of 3 11 UPC A Ins...

Страница 55: ...heck digit verification Disable 00 Enable 01 Check digit transmission Disable 00 Reserved 01 Max code length 00 99 00 99 00 Min code length 00 99 00 99 01 Code ID setting 00 FF16 ASCII 00 FF16 K Inser...

Страница 56: ...made as the sum module 103 of all data digits Check digit transmission By setting Enable check digit will be transmitted Max Min code length Refer to Max Min code length of 3 16 Code 39 Code 32 Triop...

Страница 57: ...heck digit verification Disable 00 Enable 01 Check digit transmission Disable 00 Reserved 01 Max code length 00 99 00 99 00 Min code length 00 99 00 99 01 Code ID setting 00 FF16 ASCII 00 FF16 K Inser...

Страница 58: ...16 Code 39 Code 32 Trioptic Code 39 Code ID setting Refer to Code ID setting of 3 11 UPC A Insertion group selection Refer to Insertion group selection of 3 11 UPC A Multiple scan setting Single scan...

Страница 59: ...ength of 3 16 Code 39 Code 32 Trioptic Code 39 Code ID setting Refer to Code ID setting of 3 11 UPC A Insertion group selection Refer to Insertion group selection of 3 11 UPC A Multiple scan setting S...

Страница 60: ...data digits Check digit transmission By setting Enable check digit 1 and check digit 2 will be transmitted upon your selected check digit verification method Max Min code length Refer to Max Min code...

Страница 61: ...d Disable 00 Enable 01 Check digit verification Disable 00 One digit 01 Reserved 02 Reserved 03 Check digit transmission Disable 00 Enable 01 Max code length 00 99 00 99 00 Min code length 00 99 00 99...

Страница 62: ...check digit 1 and check digit 2 will be calculated as the sum module 10 or 11 of the data digits Check digit transmission By setting Enable check digit 1 and check digit 2 will be transmitted upon yo...

Страница 63: ...Disable 00 Enable 01 Check digit verification Disable 00 1 digit mod 10 01 Reserved 02 Reserved 03 Check digit transmission Disable 00 Enable 01 Max code length 00 99 00 99 00 Min code length 00 99 00...

Страница 64: ...ode length Refer to Max Min code length of 3 16 Code 39 Code 32 Trioptic Code 39 Code ID setting Refer to Code ID setting of 3 11 UPC A Insertion group selection Refer to Insertion group selection of...

Страница 65: ...11 Code ID setting Refer to Code ID setting of 3 11 UPC A Insertion group selection Refer to Insertion group selection of 3 11 UPC A Multiple scan setting Single scan setting Option barcode Option Al...

Страница 66: ...all data digits Leading character 5 6 7 8 9 converted to A B C D E By setting leading character 5 6 7 8 9 can be converted to A B C D E Leading character assignment By setting only the barcode with t...

Страница 67: ...nverted to D 05 Only 9 converted to E 06 Leading character assignment Disable 00 Assigned to 0 01 Assigned to 5 A 02 Assigned to 6 B 03 Assigned to 7 C 04 Assigned to 8 D 05 Assigned to 9 E 06 Assigne...

Страница 68: ...3 11 UPC A Conversion UCC EAN 128 Refer to Code ID transmission of 3 42 String transmission Cm will be identified as AIM ID UPC A or EAN 13 Barcode beginning with a single zero as the first digit has...

Страница 69: ...to Insertion group selection of 3 11 UPC A Conversion Refer to Conversion of 3 30 GS1 DataBar GS1 DataBar Truncated Multiple scan setting Single scan setting Option barcode Option Alpha entry Read Dis...

Страница 70: ...C A Conversion UCC EAN 128 Refer to Code ID transmission of 3 42 String transmission Cm will be identified as AIM ID Multiple scan setting Single scan setting Option barcode Option Alpha entry Read Di...

Страница 71: ...Bar Composite UPC E Composite EAN 13 Composite GS1 composite version enabled Note 1 While this feature is enabled the decode speed will be dropped The more versions are enabled the more obvious influe...

Страница 72: ...are enabled GS1 128 Composite DataBar Composite UPC EAN Composite Three versions of GS1 Composite symbol are enabled Multiple scan setting Single scan setting Option barcode Option Alpha entry GS1 com...

Страница 73: ...67 3 34 PDF417 Read Format Data characters variable Multiple scan setting Single scan setting Option barcode Option Alpha entry Read Disable 00 Enable 01...

Страница 74: ...68 3 35 MicroPDF417 Read Format Data characters variable Multiple scan setting Single scan setting Option barcode Option Alpha entry Read Disable 00 Enable 01...

Страница 75: ...69 3 36 QR Code Read Format Data characters variable Multiple scan setting Single scan setting Option barcode Option Alpha entry Read Disable 00 Enable 01...

Страница 76: ...70 3 37 Data Matrix Read Format Data characters variable Multiple scan setting Single scan setting Option barcode Option Alpha entry Read Disable 00 Enable 01...

Страница 77: ...71 3 38 Han Xin Code Read Format Data characters variable Multiple scan setting Single scan setting Option barcode Option Alpha entry Read Disable 00 Enable 01...

Страница 78: ...72 3 39 Aztec Code Read Format Data characters variable Multiple scan setting Single scan setting Option barcode Option Alpha entry Read Disable 00 Enable 01...

Страница 79: ...for all symbols Steps 1 Scan the option barcode of Prefix string setting 2 Use the ASCII table to find the value of 24 3 Scan 2 and 4 from the barcode on the last page 4 Scan END barcode Scanning ste...

Страница 80: ...6 Steps scan the following data in order OR 8010H30 8011HFF 0407D05 Testing barcode Truncate ending G6 string setting By setting a defined ending character or string can be truncated Also a single ch...

Страница 81: ...r of characters to replace is 11 Example Replace all the A character in a data string with B character replace C with D replace E with F Original code data 1 2 3 A 4 C 5 6 E 7 8 Output code data 1 2 3...

Страница 82: ...Postamble string setting 0 22 characters 00 FF16 None 00 Insert G1 string setting 0 22 characters 00 FF16 None 00 Insert G2 string setting 0 22 characters 00 FF16 None 00 Insert G3 string setting 0 2...

Страница 83: ...times All FF Truncate ending G6 string setting A un defined character 00 1 22 defined characters 01 7F16 0 30 Repeat of a G6 character setting Once 01 Defined times 01 22 Un defined times All FF Singl...

Страница 84: ...the insertion position is greater than the length of the symbol the insertion of string is not effective Code ID position It is allowed to select different positions of code ID placement Multiple scan...

Страница 85: ...fore the code data when Enable is selected The length is represented by a number with two digits Case conversion The characters within code data or the whole output string can be set in either upper c...

Страница 86: ...nsmission Disable 00 Enable 01 Preamble transmission Disable 00 Enable 01 Postamble transmission Disable 00 Enable 01 Code ID transmission Disable 00 Proprietary ID 01 AIM ID 02 Code length transmissi...

Страница 87: ...pha entry Keyboard wedge USB 01 RS 232 02 Keyboard wedge USB RS 232 03 All non printable character string transmission with string setting Disable 00 Enable 01 Transmit the first N data characters onl...

Страница 88: ...g accuracy 1 Do not allow any abrasive material to touch the window 2 Remove any dirt particles with a damp cloth 3 Wipe the window using a tissue moistened with water 4 Do not spray water or other cl...

Страница 89: ...de is different 2 If using CODESOFT software firstly read the information through Help Index Code128 Special input syntax Also refer to ASCII table For example if we wish to make F1 barcode select COD...

Страница 90: ...8 BS CAN 9 Tab F9 HT EM A F10 LF SUB B Home Esc VT ESC C End F11 FF FS D Enter F12 CR GS E Insert Ctrl SO RS F Delete Alt SI US Notes The 2nd and the 3rd columns above are used for keyboard wedge only...

Страница 91: ...85 7 Test barcode UPC A UPC E UPC E1 EAN 8 EAN 13 Code 39 Code 32 A908765439 Code 128 Interleaved 2 of 5 Industrial 2 of 5 Default setting Read disable Matrix 2 of 5 Code 93...

Страница 92: ...86 UCC EAN 128 Code 11 Default setting Read disable MSI Plessey Default setting Read disable UK Plessey ISBN ISSN China Post GS1 DataBar GS1 DataBar Truncated GS1 DataBar Limited GS1 DataBar Expanded...

Страница 93: ...87 PDF417 12 890ab xyz MicroPDF417 0239 mdo QR code 1234567890ABCD XYZ Data Matrix 123890abc mdo...

Страница 94: ...88 Aztec Code 12345678901234567890 Han Xin Code 12345678901234567890...

Страница 95: ...re version WARNING Default value initialization If you wish to return the image platform to all the factory default settings scan the barcode above Firmware version list If you wish to display the fir...

Страница 96: ...90 9 Configuration alphanumeric entry barcode To finish parameter setting please scan the bar code below...

Отзывы: