background image

12 

3-3 Interface selection 

This image platform supports interfaces such as RS-232 serial wedge, and USB interface. In most of the 
cases,  simply  selecting  an  appropriate  cable  provided  by  the  manufacturer  will  work  for  a  specific 
interface. 

 
Interface selection: 

Auto detection- By setting this function,  the image platform will automatically  detect the RS-232 or 
USB interface for user. 

 

Multiple-scan setting

 

Single-scan setting 

Option barcode 

Option 

Alpha. entry 

Interface selection 

 

Auto detection 
(RS-232/USB) 

00* 

 

 

 

 

 

Содержание MP8600

Страница 1: ...MP8600 Image Platform User Manual Version MP8600_UM_EN_V1 1 6...

Страница 2: ......

Страница 3: ...ed to the user is on a licensed basis 2 The right is reserved to make changes to any software or product to improve reliability function or design 3 The material in this manual is subject to change wi...

Страница 4: ...ii...

Страница 5: ...de 11 3 3 Interface selection 12 3 4 RS 232 interface 13 3 5 USB interface 15 3 6 Scan mode some global settings 18 3 7 LED and Beeper Indication 23 3 8 LED illumination level 25 3 9 Single type of ba...

Страница 6: ...QR Code 74 3 37 MicroQR Code 75 3 38 Data Matrix 76 3 39 Han Xin Code 77 3 40 Aztec Code 78 3 41 G1 G6 C1 C3 FN1 substitution string setting 79 3 42 G1 G4 string position Code ID position 84 3 43 Str...

Страница 7: ...PC A UPC E UPC E1 EAN 13 EAN 8 ISBN Bookland EAN ISSN Code 39 Code 39 full ASCII Code 32 Trioptic Code 39 Interleaved 2 of 5 Industrial 2 of 5 Discrete 2 of 5 Matrix 2 of 5 Codabar NW7 Code 128 UCC EA...

Страница 8: ...2 Safety EMC EN55032 EN55024 Electrical Safety EN60950 1 Photobiological Safety EN62471 2008 Illumination 0 100 000 LUX Sealing IP52...

Страница 9: ...odabar 4 N Fm Code 128 1 K Cm UCC EAN 128 GS1 128 1 K Cm ISBT 128 1 K Cm Code 93 1 L Gm Code 11 4 V Hm MSI Plessey 4 O Mm UK Plessey 1 U Mm China Post 11 2 T Im China Finance 10 2 Y GS1 DataBar 16 2 R...

Страница 10: ...auto selection purpose 3 3V for interface auto selection purpose 3 Ground Ground 4 3 3V for interface auto selection purpose Ground for interface auto selection purpose 5 TxD Reserved 6 RxD Reserved...

Страница 11: ...5 2 2 Dimensions Figure 2 2 Dimensions without stand Figure 2 3 Dimensions with stand Figure 2 4 Dimensions of hanging holes...

Страница 12: ...6 2 3 Field of view Figure 2 5 Field of view Figure 2 6 Field of view Front view...

Страница 13: ...7 Figure 2 7 Field of view Horizontal Figure 2 8 Field of view Vertical...

Страница 14: ...of image platform Figure 2 9 Parts of image platform Exit window Camera push button Beeper push button LED Beeper Hanging holes Release hole of cable Host interface Auxiliary interface for handheld s...

Страница 15: ...power supply on PIN 9 connect the external power supply 5 V DC adapter to the RS 232 cable 5 Switch on the host If connect properly the beeper and the LED of the image platform will indicate Figure 2...

Страница 16: ...Scan the appropriate Single scan setting according to the user s demand Example To set Flow control to be XON XOFF Steps Scan the following barcode Multiple scan setting Step 1 Scan the Option barcode...

Страница 17: ...aracter string with various length of 2 4 or other values Example Set 0401 03 decimal 8002 0D0A hexadecimal 8202 01 decimal The customized QR code barcode contents and symbol are as following 0401D03...

Страница 18: ...an appropriate cable provided by the manufacturer will work for a specific interface Interface selection Auto detection By setting this function the image platform will automatically detect the RS 232...

Страница 19: ...image platform receives an XON character ACK NAK After transmitting data the image platform expects either an ACK acknowledge or NAK not acknowledge response from the host When a NAK is received the...

Страница 20: ...ode Option Alpha entry 80 ms 05 Response delay 00 99 100 ms 00 99 00 Baud rate 300 00 600 01 1200 02 2400 03 4800 04 9600 05 19200 06 38400 07 57600 08 115200 09 Parity bit None 00 Odd 01 Even 02 Data...

Страница 21: ...e instruction Keyboard layout The image platform supports different national keyboard layouts Commonly an appropriate encoding system must be selected Please refer to Character encoding system of 3 6...

Страница 22: ...HID keyboard 00 HID keyboard for Apple Mac 01 USB virtual COM 02 Simple COM Port Emulation 03 Keyboard layout USA 00 Turkish F 01 Turkish Q 02 French 03 Italian 04 Spanish 05 Slovak 06 Denmark 07 Japa...

Страница 23: ...l settings Inter character delay 0 ms 00 5 ms 01 10 ms 02 20 ms 03 40 ms 04 60 ms 05 Numeric key Alphabetic key 00 Numeric keypad 01 Alt keypad 02 GBK 03 BIGS 04 THAI 05 USB function code Output non p...

Страница 24: ...ond delay time When this feature is set to be 0xFF then the delay time is indefinite Same barcode delay time for 2D symbol If a 2D barcode has been scanned and output once successfully the image platf...

Страница 25: ...is parameter is set to be 00 the image platform will not store data And if the parameter is set to be FF the image platform will output data after stopping scanning Character encoding system A charact...

Страница 26: ...ion Good read off 07 Barcode detection Disable 00 Enable 01 Barcode detection delay Always detection 00 5 seconds 01 10 seconds 02 30 seconds 03 60 seconds 04 Never detection 05 Standby duration 5 sec...

Страница 27: ...FF16 50 ms 00 FF16 00 08 Double confirm 00 09 00 no 00 09 00 Global max code length for 1D symbol 04 99 04 99 99 Global min code length for 1D symbol 01 99 01 99 04 Global G1 G6 string selection 00 6...

Страница 28: ...ngle scan setting Option barcode Option Alpha entry UTF 8 01 Windows 1251 02 Simplified Chinese 03 Traditional Chinese 04 Windows 1250 05 KOI8R 06 Japanese 07 Complete data output before next decode a...

Страница 29: ...ccessful reading the image platform will beep to indicate a good barcode reading and its beep tone duration is adjustable Beep tone duration This parameter can be adjusted for a good reading upon favo...

Страница 30: ...de Option Alpha entry Power on alert Disable 00 Enable 01 LED indication Disable 00 Enable 01 Beeper indication Disable 00 Enable 01 Beep tone duration 01 09 10 ms 01 09 05 Volume of beeper Low 00 Mid...

Страница 31: ...to the target increases Level of decode illumination This parameter can be adjusted for different level of decode illumination Illumination mode of Auto detection Always off Illumination LED will be a...

Страница 32: ...entry Decode illumination mode Always Off 00 Always On 01 On when reading 03 Level of decode illumination Disable decode illumination 00 Low 01 Middle 02 High 03 Illumination mode of Auto detection A...

Страница 33: ...ols in one image By setting Disable the image platform will only read the symbol closest to the center area in the image Multiple scan setting Single scan setting Option barcode Option Alpha entry 1D...

Страница 34: ...The symbol types which support Structured Append include QR code Aztec code PDF417 and DataMatrix The lower part of below figure shows an example of four Structured Append symbols with the same data...

Страница 35: ...ultiple scan setting Single scan setting Option barcode Option Alpha entry DPM format read Disable 00 Enable 01 Structured append symbols read Disable 00 Enable 01 Mobile screen read Disable 00 Enable...

Страница 36: ...n barcode or send command to enter upgrade mode Scan barcode to enter upgrade mode Send command to enter upgrade mode Send command 0x16 0x4D 0x0D 0x25 0x4E 0x4D 0x55 0x47 0x44 0x2E by USB virtual COM...

Страница 37: ...e Supplement digits barcode is the supplemental 2 or 5 characters Format System character Data digits 10 digits Check digit 1 digit Supplement digits 2 or 5 Truncation Expansion Truncate leading zeros...

Страница 38: ...Check digit trans Disable 00 Enable 01 Code ID setting 00 FF16 ASCII 00 FF16 A Insert group selection 00 66 00 66 00 Supplement digits None 00 2 digits 01 5 digits 02 2 or 5 digits 03 Read only UPC A...

Страница 39: ...33 Multiple scan setting Single scan setting Option barcode Option Alpha entry...

Страница 40: ...Truncation Expansion Truncate leading zeros The leading 0 digits of UPC E data characters can be truncated when the feature is enabled Example Barcode 00123457 Output 123457 Expand to EAN 13 It extend...

Страница 41: ...it trans Disable 00 Enable 01 Code ID setting 00 FF16 ASCII 00 FF16 D Insert group selection 00 66 00 66 00 Supplement digits None 00 2 digits 01 5 digits 02 2 or 5 digits 03 Read only UPC E with Supp...

Страница 42: ...36 Multiple scan setting Single scan setting Option barcode Option Alpha entry...

Страница 43: ...em character 1 Data digits 6 digits Check digit 1 digit Supplement digits 2 or 5 Truncation Expansion Expand to EAN 13 It extends to 13 digits with 0 digits when the feature is enabled Example Barcode...

Страница 44: ...01 Check digit trans Disable 00 Enable 01 Code ID setting 00 FF16 ASCII 00 FF16 D Insert group selection 00 66 00 66 00 Supplement digits None 00 2 digits 01 5 digits 02 2 or 5 digits 03 Read only UP...

Страница 45: ...to Insertion group selection of 3 11 UPC A Supplement digits Format Data digits 12 digits Check digit 1 digit Supplement digits 2 or 5 ISBN ISSN conversion The ISBN International Standard Book Number...

Страница 46: ...nable 01 Check digit transmission Disable 00 Enable 01 EAN 13 code ID setting 00 FF16 ASCII 00 FF16 A Insert group selection 00 66 00 66 00 Supplement digits None 00 2 digits 01 5 digits 02 2 or 5 dig...

Страница 47: ...41...

Страница 48: ...e data digits Check digit trans By setting Enable check digit will be transmitted Code ID setting Refer to Code ID setting of 3 11 UPC A Insertion group selection Refer to Insertion group selection of...

Страница 49: ...tion Disable 00 Enable 01 Check digit trans Disable 00 Enable 01 Code ID setting 00 FF16 ASCII 00 FF16 C Insert group selection 00 66 00 66 00 Supplement digits None 00 2 digits 01 5 digits 02 2 or 5...

Страница 50: ...ength barcode decoded Code ID setting Refer to Code ID setting of 3 11 UPC A Insertion group selection Refer to Insertion group selection of 3 11 UPC A Start End transmission The start and end charact...

Страница 51: ...le 01 Check digit transmission Disable 00 Enable 01 Max code length 00 99 00 99 00 Min code length 00 99 00 99 01 Code ID setting 00 FF16 ASCII 00 FF16 M Insert group selection 00 66 00 66 00 Format S...

Страница 52: ...ng Single scan setting Option barcode Option Alpha entry Enable 01 Code 32 Prefix A transmission Disable 00 Enable 01 Trioptic Code 39 read Disable 00 Enable 01 Trioptic Code 39 Start End transmission...

Страница 53: ...optional check digit algorithms the specified Uniform Symbol Specification USS and the Optical Product Code Council OPCC Check digit transmission By setting Enable check digit will be transmitted Max...

Страница 54: ...a entry Read Disable 00 Enable 01 Check digit verification Disable 00 USS 01 OPCC 02 Check digit transmission Disable 00 Enable 01 Max code length 00 99 00 99 00 Min code length 00 99 00 99 06 Code ID...

Страница 55: ...e ID setting Refer to Code ID setting of 3 11 UPC A Insertion group selection Refer to Insertion group selection of 3 11 UPC A Multiple scan setting Single scan setting Option barcode Option Alpha ent...

Страница 56: ...length of 3 16 Code 39 Code 32 Trioptic Code 39 Code ID setting Refer to Code ID setting of 3 11 UPC A Insertion group selection Refer to Insertion group selection of 3 11 UPC A Multiple scan setting...

Страница 57: ...Insertion group selection of 3 11 UPC A Start End type Codabar has four pairs of Start End pattern you may select one pair to match your application Start End transmission Refer to Start End transmis...

Страница 58: ...tting Option barcode Option Alpha entry Insert group selection 00 66 00 66 00 Start End type ABCD ABCD 00 abcd abcd 01 ABCD TN E 02 abcd tn e 03 Start End transmission Disable 00 Enable 01 Start End c...

Страница 59: ...n By setting Enable check digit will be transmitted Max Min code length Refer to Max Min code length of 3 16 Code 39 Code 32 Trioptic Code 39 Code ID setting Refer to Code ID setting of 3 11 UPC A Ins...

Страница 60: ...heck digit verification Disable 00 Enable 01 Check digit transmission Disable 00 Reserved 01 Max code length 00 99 00 99 00 Min code length 00 99 00 99 01 Code ID setting 00 FF16 ASCII 00 FF16 K Inser...

Страница 61: ...made as the sum module 103 of all data digits Check digit transmission By setting Enable check digit will be transmitted Max Min code length Refer to Max Min code length of 3 16 Code 39 Code 32 Triop...

Страница 62: ...heck digit verification Disable 00 Enable 01 Check digit transmission Disable 00 Reserved 01 Max code length 00 99 00 99 00 Min code length 00 99 00 99 01 Code ID setting 00 FF16 ASCII 00 FF16 K Inser...

Страница 63: ...16 Code 39 Code 32 Trioptic Code 39 Code ID setting Refer to Code ID setting of 3 11 UPC A Insertion group selection Refer to Insertion group selection of 3 11 UPC A Multiple scan setting Single scan...

Страница 64: ...ength of 3 16 Code 39 Code 32 Trioptic Code 39 Code ID setting Refer to Code ID setting of 3 11 UPC A Insertion group selection Refer to Insertion group selection of 3 11 UPC A Multiple scan setting S...

Страница 65: ...data digits Check digit transmission By setting Enable check digit 1 and check digit 2 will be transmitted upon your selected check digit verification method Max Min code length Refer to Max Min code...

Страница 66: ...d Disable 00 Enable 01 Check digit verification Disable 00 One digit 01 Reserved 02 Reserved 03 Check digit transmission Disable 00 Enable 01 Max code length 00 99 00 99 00 Min code length 00 99 00 99...

Страница 67: ...check digit 1 and check digit 2 will be calculated as the sum module 10 or 11 of the data digits Check digit transmission By setting Enable check digit 1 and check digit 2 will be transmitted upon yo...

Страница 68: ...Disable 00 Enable 01 Check digit verification Disable 00 1 digit mod 10 01 Reserved 02 Reserved 03 Check digit transmission Disable 00 Enable 01 Max code length 00 99 00 99 00 Min code length 00 99 00...

Страница 69: ...ode length Refer to Max Min code length of 3 16 Code 39 Code 32 Trioptic Code 39 Code ID setting Refer to Code ID setting of 3 11 UPC A Insertion group selection Refer to Insertion group selection of...

Страница 70: ...11 Code ID setting Refer to Code ID setting of 3 11 UPC A Insertion group selection Refer to Insertion group selection of 3 11 UPC A Multiple scan setting Single scan setting Option barcode Option Al...

Страница 71: ...all data digits Leading character 5 6 7 8 9 converted to A B C D E By setting leading character 5 6 7 8 9 can be converted to A B C D E Leading character assignment By setting only the barcode with t...

Страница 72: ...nverted to D 05 Only 9 converted to E 06 Leading character assignment Disable 00 Assigned to 0 01 Assigned to 5 A 02 Assigned to 6 B 03 Assigned to 7 C 04 Assigned to 8 D 05 Assigned to 9 E 06 Assigne...

Страница 73: ...3 11 UPC A Conversion UCC EAN 128 Refer to Code ID transmission of 3 42 String transmission Cm will be identified as AIM ID UPC A or EAN 13 Barcode beginning with a single zero as the first digit has...

Страница 74: ...to Insertion group selection of 3 11 UPC A Conversion Refer to Conversion of 3 30 GS1 DataBar GS1 DataBar Truncated Multiple scan setting Single scan setting Option barcode Option Alpha entry Read Dis...

Страница 75: ...C A Conversion UCC EAN 128 Refer to Code ID transmission of 3 42 String transmission Cm will be identified as AIM ID Multiple scan setting Single scan setting Option barcode Option Alpha entry Read Di...

Страница 76: ...Bar Composite UPC E Composite EAN 13 Composite GS1 composite version enabled Note 1 While this feature is enabled the decode speed will be dropped The more versions are enabled the more obvious influe...

Страница 77: ...are enabled GS1 128 Composite DataBar Composite UPC EAN Composite Three versions of GS1 Composite symbol are enabled Multiple scan setting Single scan setting Option barcode Option Alpha entry GS1 com...

Страница 78: ...72 3 34 PDF417 Read Format Data characters variable Multiple scan setting Single scan setting Option barcode Option Alpha entry Read Disable 00 Enable 01...

Страница 79: ...73 3 35 MicroPDF417 Read Format Data characters variable Multiple scan setting Single scan setting Option barcode Option Alpha entry Read Disable 00 Enable 01...

Страница 80: ...74 3 36 QR Code Read Format Data characters variable Multiple scan setting Single scan setting Option barcode Option Alpha entry Read Disable 00 Enable 01 Website link QR code Enable 00 Disable 01...

Страница 81: ...de Note The support for this feature is available with customized firmware version Read Format Data digits variable Multiple scan setting Single scan setting Option barcode Option Alpha entry Read Dis...

Страница 82: ...76 3 38 Data Matrix Read Format Data characters variable Multiple scan setting Single scan setting Option barcode Option Alpha entry Read Disable 00 Enable 01...

Страница 83: ...77 3 39 Han Xin Code Read Format Data characters variable Multiple scan setting Single scan setting Option barcode Option Alpha entry Read Disable 00 Enable 01...

Страница 84: ...78 3 40 Aztec Code Read Format Data characters variable Multiple scan setting Single scan setting Option barcode Option Alpha entry Read Disable 00 Enable 01...

Страница 85: ...for all symbols Steps 1 Scan the option barcode of Prefix string setting 2 Use the ASCII table to find the value of 24 3 Scan 2 and 4 from the barcode on the last page 4 Scan END barcode Scanning ste...

Страница 86: ...6 Steps scan the following data in order OR 8010H30 8011HFF 0407D05 Testing barcode Truncate ending G6 string setting By setting a defined ending character or string can be truncated Also a single ch...

Страница 87: ...r of characters to replace is 11 Example Replace all the A character in a data string with B character replace C with D replace E with F Original code data 1 2 3 A 4 C 5 6 E 7 8 Output code data 1 2 3...

Страница 88: ...Postamble string setting 0 22 characters 00 FF16 None 00 Insert G1 string setting 0 22 characters 00 FF16 None 00 Insert G2 string setting 0 22 characters 00 FF16 None 00 Insert G3 string setting 0 2...

Страница 89: ...times All FF Truncate ending G6 string setting A un defined character 00 1 22 defined characters 01 7F16 0 30 Repeat of a G6 character setting Once 01 Defined times 01 22 Un defined times All FF Singl...

Страница 90: ...the insertion position is greater than the length of the symbol the insertion of string is not effective Code ID position It is allowed to select different positions of code ID placement Multiple scan...

Страница 91: ...fore the code data when Enable is selected The length is represented by a number with two digits Case conversion The characters within code data or the whole output string can be set in either upper c...

Страница 92: ...nsmission Disable 00 Enable 01 Preamble transmission Disable 00 Enable 01 Postamble transmission Disable 00 Enable 01 Code ID transmission Disable 00 Proprietary ID 01 AIM ID 02 Code length transmissi...

Страница 93: ...pha entry Keyboard wedge USB 01 RS 232 02 Keyboard wedge USB RS 232 03 All non printable character string transmission with string setting Disable 00 Enable 01 Transmit the first N data characters onl...

Страница 94: ...g accuracy 1 Do not allow any abrasive material to touch the window 2 Remove any dirt particles with a damp cloth 3 Wipe the window using a tissue moistened with water 4 Do not spray water or other cl...

Страница 95: ...m 2 As shown in Figure 5 2 well connect the image platform with the stand by tightening the single screw 3 As shown in Figure 5 3 adjust the image platform forward backward for a desired position 4 As...

Страница 96: ...de is different 2 If using CODESOFT software firstly read the information through Help Index Code128 Special input syntax Also refer to ASCII table For example if we wish to make F1 barcode select COD...

Страница 97: ...8 BS CAN 9 Tab F9 HT EM A F10 LF SUB B Home Esc VT ESC C End F11 FF FS D Enter F12 CR GS E Insert Ctrl SO RS F Delete Alt SI US Notes The 2nd and the 3rd columns above are used for keyboard wedge only...

Страница 98: ...92 8 Test barcode UPC A UPC E UPC E1 EAN 8 EAN 13 Code 39 Code 32 A908765439 Code 128 Interleaved 2 of 5 Industrial 2 of 5 Default setting Read disable Matrix 2 of 5 Code 93...

Страница 99: ...93 UCC EAN 128 Code 11 Default setting Read disable MSI Plessey Default setting Read disable UK Plessey ISBN ISSN China Post GS1 DataBar GS1 DataBar Truncated GS1 DataBar Limited GS1 DataBar Expanded...

Страница 100: ...94 PDF417 12 890ab xyz MicroPDF417 0239 mdo QR code 1234567890ABCD XYZ Data Matrix 123890abc mdo...

Страница 101: ...95 Aztec Code 12345678901234567890 Han Xin Code 12345678901234567890...

Страница 102: ...re version WARNING Default value initialization If you wish to return the image platform to all the factory default settings scan the barcode above Firmware version list If you wish to display the fir...

Страница 103: ...97 10 Configuration alphanumeric entry barcode To finish parameter setting please scan the bar code below...

Отзывы: