60
GS1 DataBar (GS1 DataBar Truncated)
GS1 DataBar Truncated is structured and encoded the same as the standard GS1 DataBar format,
except its height is reduced to a 13 modules minimum; while GS1 DataBar should have a height greater
than or equal to 33 modules.
Read:
Format
16 Data digits
Code ID setting: Refer to Code ID setting of UPC-A.
Insertion group selection: Refer to Insertion group selection of UPC-A.
Conversion:
UCC/EAN 128- Refer to Code ID transmission of String transmission, ]Cm will be identified as AIM ID.
UPC-A or EAN-13- Barcode beginning with a single zero as the first digit has the leading “010” stripped
and the barcode reported as EAN-13. Barcode beginning with two or more zeros but not six zeros has
the leading “0100” stripped and the barcode reported as UPC-A.
Multiple-scan setting
Single-scan setting
Option bar code
Option
Alpha. entry
Read
Disable
00
Enable
01*
*
Code ID setting
00-FF
16
(ASCII)
00-FF
16
<R >*
*
Insert group selection
00-66
00-66
00*
*
Conversion
None
00*
*
UCC/EAN 128
01
UPC-A or EAN-13
02