![Mindeo FS580 Скачать руководство пользователя страница 52](http://html1.mh-extra.com/html/mindeo/fs580/fs580_user-manual_1800665052.webp)
46
4-16 Codabar
Read:
Format
Start character
Data digits (variable)
Check digit (optional)
End character
Check digit verification: The check digit verification is optional.
Check digit transmission: By setting Enable, check digit will be transmitted.
Max./Min. code length: Refer to Max./Min. code length of
“
4-12 Code 39 (Code 32, Trioptic Code 39)
”
.
Code ID setting: Refer to Code ID setting of
“
4-7 UPC-A
”
.
Insertion group selection: Refer to Insertion group selection of
“
4-7 UPC-A
”
.
Start/End type: Codabar has four pairs of Start/End pattern; you may select one pair to match your
application.
Start/End transmission: By setting Enable, the start and end character of a Codabar barcode will be
transmitted.
Start/End character equality: By setting Enable, the start and end character of a Codabar barcode must
be the same.
SETUP
Multiple-scan setting
Single-scan setting
Option barcode
Option
Alpha. value
Read
Disable
00
Enable
01*
Check digit verification
Disable
00*
Enable
01
Check digit transmission
Disable
00*
Enable
01
Max. code length
00-99
00-99
99*
Содержание FS580
Страница 1: ...FS580 Industrial Fixed Laser Barcode Scanner User Manual Version FS580_UM_EN_V1 1 6...
Страница 2: ......
Страница 8: ...2 Figure 1 1 Pitch Skew and Roll...
Страница 16: ...10 3 4 Scan angle Scan angle Narrow 40 5 Scan angle Wide 55 5 Figure 3 4 Scan angle...
Страница 74: ...68 Testing barcode...
Страница 97: ...91 Host Scanner 1 PARAM_REQUEST 2 PARAM_SEND...
Страница 114: ...108 12 Configuration alphanumeric value barcode as Para value To finish parameter setting please scan the bar code below...