Tel: 763. 571.3121  •  Fax: 763. 571.0927  •  www.minco.com 

10 

 
 
Warranty 

Items returned within one year from the date of sale, transportation prepaid, which Minco 

Products, Inc. (the “seller”) reasonably determines to be faulty by reason of defective materials 

or faulty workmanship will be replaced or repaired at 

the seller’s discretion, free of charge.

 

 
This remedy is to be the sole and exclusive remedy available to the buyer in the event of a 
breach by the seller.  Items that show evidence of mishandling or misapplication may be 
returned by the seller at the cust

omer’s expense.

 

 
Furthermore, the seller is not to be held responsible for consequential damages caused by this 
product except as required under Minnesota Statutes, Section 336.1-719 (3). 
 
This warranty is in lieu of any other expressed warranty or implied warranty of merchantability 
or fitness for a particular purpose, and of any other obligations or liability of the seller or its 
employees or agent. 
 
 
 
 

Содержание TT859

Страница 1: ...Tel 763 571 3121 Fax 763 571 0927 www minco com TT859 TemptranTM 2 wire Temperature Transmitter for RTD Thermometers Installation and Operating Instructions...

Страница 2: ...4 to 20 mA DC current The current changes according to the range in which the Temptran is calibrated 4 mA at the lowest temperature of the range rising to 20 mA at the top of the range The leads that...

Страница 3: ...cts 0 01 Span F 0 018 Span C Warm up Drift 0 1 of span max assuming Vsupply 24 VDC and Rloop 250 ohms Stable within 15 minutes Supply Voltage 9 4 to 35 volts DC non polarized Input Voltage Effect 0 00...

Страница 4: ...or non polar hook up so polarity is not important If calibration is necessary set dip switches before assembling housing See Transmitter Ranging section Connect a DC source not exceeding 35 VDC to the...

Страница 5: ...esponding to the lower temperature and verify that the milliammeter still reads 4 0 mA 0 016 mA Correct if necessary then repeat steps 4 and 5 Transmitter Ranging The transmitter is initially calibrat...

Страница 6: ...ent adjustments the switch settings should then be changed In the above example if the Zero trim pot cannot adjust the transmitter current down to 4mA with the 30 F Zero switch settings then the Zero...

Страница 7: ...74 41 ON OFF OFF ON 81 45 ON OFF OFF OFF 90 50 OFF ON ON ON 99 55 OFF ON ON OFF 106 59 OFF ON OFF ON 115 64 OFF ON OFF OFF 122 68 OFF OFF ON ON 131 73 OFF OFF ON OFF 139 77 OFF OFF OFF ON 148 82 OFF...

Страница 8: ...7 45 1328 03 1338 61 1349 18 200 PW 1350 38 1360 64 1370 90 PF 1359 74 1370 30 1380 84 Temp C Sensor 0 2 4 6 8 10 12 14 16 18 20 PW 923 55 915 88 908 20 900 52 PF 921 60 913 73 905 86 897 99 0 PW 1000...

Страница 9: ...to 60 C S 0 to100 F 18 to 38 C A 20 to120 F 7 to49 C BI 30 to130 F 1 to54 C N 32 to122 F 0 to50 C H 40 to90 F 4 to32 C SX Special range as defined on job order must fall within adjustment limits of T...

Страница 10: ...exclusive remedy available to the buyer in the event of a breach by the seller Items that show evidence of mishandling or misapplication may be returned by the seller at the customer s expense Further...

Страница 11: ...et Service Minneapolis MN Tel 1 763 571 3123 Commercial Z I 55432 Fax 1 763 571 0942 09310 Aston France USA custserv minco com Tel 33 5 61 03 24 01 Tel 1 763 571 3121 www minco com Fax 33 5 61 03 24...