10
Installation
Connections
Warning
Do not connect this equipment with power applied.
Failure to heed this directive may result in fire or serious
injury.
Minarik strongly recommends the installation of a master
power switch in the voltage input line, as shown in
Figure 4 (page 13) or Figure 5 (page 14). The switch
contacts should be rated at a minimum of 200% of motor
nameplate current and 250 volts.
Power, fuse and motor connections
If you use a PCM2x000A-series drive, connect the power input
leads, an external line fuse and a DC motor to the drive’s printed
circuit board (PCB) as shown in Figure 4, page 13.
If you use a PCM2x000C-series drive, refer to Figure 5 (page 14).
Motor
Connect a DC motor to PCB terminals A1 and A2 as shown in
Figure 4. Ensure that the motor voltage rating is consistent
with the drive’s output voltage.
250-0090-rev5.qxd 3/9/01 10:25 AM Page 10