4
MM21036A/MM22036A INSTALLATION GUIDE
Figure 2. Calibration Trimpot Layout
Calibration
The control is factory calibrated with OFFSET at 0° and SPAN
at 300°. The MAX SPD trimpot is adjusted to 85V DC
(MM21036A) and 170V DC (MM22036A), at no load.
Calibrate the drive using the following procedure:
1.
Set the MIN SPD and OFFSET trimpots to zero (full
CCW).
2.
Set the SPAN, MAX SPD and TORQUE trimpots to
maximum (full CW).
3.
Set the IR COMP trimpot to midrange (approximate 12
o’clock position).
4.
Set the dancer potentiometer wiper to minimum.
5.
Apply power to the drive.
6.
Calibrate the trimpots as follows: