Gas connections on the heater are leak tested at the factory prior to shipment. A complete gas 
tightness check must be performed due to possible mishandling in shipment or excessive pressure 
being applied to the heater gas connections.

1.Make a soap solution of one part liquid detergent and one part water.

Make sure the control knob on the heater is off and the gas valve on the cylinder is off before 
mixing the soapy solution.

2.Turn on the gas bottle.

3. Apply the soap solution to the gas connections using a soft bristle brush.

Soap bubbles will appear 

if there is a gas leak.

In case of a leak, turn off  

the gas supply. Tighen any 

leaking fittings, then turn the 

gas supply on and re-check.

If there is a leak anywhere 

on the gas cylinder, do not 

use the cylinder. Locate the 

leaking cylinder outdoors 

away from sources of 

ignition, then contact your 

local gas authority or 

cylinder exchange provider 

to arrange disposal. 

Warning

Do not operate the appliance until all gas leaks have been rectified.
Never leak test while smoking.

+

+

+

+

+

+

Regulator / Cylinder

Hose / Regulator 

Detergent

Gas Leak Test

Содержание 0151858

Страница 1: ...OUTDOOR GAS AREA HEATER STAINLESS STEEL Provides warmth and ambiance for outdoor settings AGA Gas Certified Important Please retain these instructions for future use 0151858 0151858 SAH004 ODS SS 201...

Страница 2: ...e gas bottle 3 Apply the soap solution to the gas connections using a soft bristle brush Soap bubbles will appear if there is a gas leak In case of a leak turn off the gas supply Tighen any leaking fi...

Страница 3: ...2 Gas Requirements Page 4 Leakage Test Page 4 Operation and Storage Page 5 Cleaning and Care Page 6 Parts and Specifications Page 6 Assembly Parts and Procedures Page 7 Assembly Steps Page 8 Pilot Se...

Страница 4: ...cleaning may be required as necessary The gas cylinder should be turned off when the heater is not in use Check the heater immediately if any of the following occurs the heater does not reach tempera...

Страница 5: ...e of balconies at least 20 of the total wall area shall be and remain open and unrestricted Never operate heater in an explosive atmosphere like in areas where petrol or other flammable liquids or vap...

Страница 6: ...Both ends open Open side at least 25 of total wall area 30 percent or more in total of the remaining wall area is open and unrestricted Page 3...

Страница 7: ...d due to possible mishandling in shipment or excessive pressure being applied to the heater Make a soap solution of one part liquid detergent and one part water The soap solution can be applied with a...

Страница 8: ...s dealer 4 Never store gas cylinders underground or in places without adequate air ventilation 5 There is no limitation on the storage of appliances indoors provided that the cylinder is removed from...

Страница 9: ...ible or corrosive Remove debris from the burner to keep it clean and safe for use Cover the burner unit with the optional protective cover when the heater is not in use Flame screen guard Burner assem...

Страница 10: ...d flare type with internal O ring seal 6PCS M5 x 12 screw for stand and stand connectors 4pcs Self Taping Screws for burner head and tank housing body 4pcs M5X12 screw for tank housing body and stand...

Страница 11: ...P 2 Use 4pcs M5X12 screw to join the tank housing base and stand Use 6pcs M5X12 screw to join the stand and stand connectors STEP 2 STEP 1 STEP 1 Tank housing body M5X12 Screw Stand Page 8 Assembly St...

Страница 12: ...first one as shown in photos 3 2 Use 4pcs Self Taping Screws join the burner head and tank housing body STEP 3 Burner Head STEP 3 STEP 4 STEP 4 Use the M6 Dome Nut connect the two half safety guards t...

Страница 13: ...iter button then install the battery and tighten igniter button 5 4 Then leak test the gas inlet and gas cylinder connections as explained on page 4 5 5 Put the gas cylinder into the tank housing then...

Страница 14: ...SHUIRUDWHG HPLWWHU WR DFFHVV WKH SLORW 7KHQ LQVHUW D SLSH FOHDQHU LQWR WKH DLU KROHV DW WKH EDVH RI WKH SLORW WXEH and in the pilot burner tube as shown below to clear spider webV RU QHVWV ORZ DLU WK...

Страница 15: ...uel pressure Tank near empty Service pilot as shown in this manual Tighten connections Check connections Replace thermocouple Refill gas cylinder Burner flame is low Supply hose is bent or twisted Str...

Страница 16: ...Consumer Law or Consumer Guarantees Act 1993 NZ You are entitled to replacement or refund for a major failure and to compensation for other reasonably foreseeable loss or damage You are also entitled...

Отзывы: