MIMAKI UJV500 Скачать руководство пользователя страница 1

Make sure to wear the attached 

goggles and glove

 when you work.

© 2014 MIMAKI ENGINEERING CO., LTD.        M014557-02(D202548-12)-06062014

UJV500 Daily Care

With a view to using this machine in a better condition, please be sure to the following daily care 

after at the end of the

daily work

. Please refer to “Daily care manual” for the detail.

1. Perform [HEAD MAINT.], move the carriage to the 

maintenance position and open the left maintenance cover.

(1) Press the 

 key in LOCAL.

(2) Press the 

 key.

(3) Press 

 to select [HEAD MAINT.].

(4) Press the 

 key.

(5) Open the left maintenance cover.

2. Wipe off the ink of around  the head and groove with clean stick or waste cloth dipped in

cleaning solution for maintenance.

3. If there is any ink stuck on the bottom surface of the left UV lamp, apply the cleaning

solution for maintenance to a clean stick and wipe the ink away.

4. Open the right maintenance cover.

Left maintenance 

cover

MAINT.

• When you clean , fully be careful 

not to touch the nozzle surface.

[Before cleaning]

[During cleaning]

[After cleaning]

• When you leave during maintenance (or cleaning), please make sure to complete the cleaning  

by pressing 

 key. Without completing the cleaning, the nozzle part is left uncovered 

and then outside light makes the ink cure, which causes nozzle clogging or the like.

• Wipe off so that cleaning solution 

for maintenance will not remain.

Right maintenance 

cover

IT