MIMAKI UJV500 Series Скачать руководство пользователя страница 2

6. Press the 

 key.

Sensor adjustment starts.

7. Rotate the adjustment screw of the throttle valve to adjust the

pressure so that it becomes the proper value

Proper value of negative pressure

: -5.4kPa

Proper value of positive pressure

: 15.00kPa

•As the negative pressure changes between ±0.1 and 0.2kPa, adjust so that the intermediate value may become the target pressure.
•Adjust the throttle valve in order of “negative pressure” 

 “positive pressure” 

 “negative pressure”.

8. Press the 

 key.

The error is released and the negative pressure control starts.

* * AD J US T I NG * *

P L EASE WA I T

PRESSURE

=

- 4 . 0 0 k P a

• Status of lamp and buzzer for each pressure value

Pressure

Ink bottle lamp Buzzer

Positive pressure Negative pressure

High

8.49

-4.75

Sounds

8.50

9.49

-4.76

-4.85

9.50

10.49

-4.86

-4.95

10.50

11.49

-4.96

-5.05

11.50

12.49

-5.06

-5.15

12.50

13.49

-5.16

-5.25

13.50

14.49

-5.26

-5.35

Stops

Proper 

value

14.50

15.49

-5.36

-5.45

Stops

Low

15.50

16.49

-5.46

-5.55

Stops

16.50

17.49

-5.56

-5.65

Sounds

17.50

18.49

-5.66

-5.75

18.50

19.49

-5.76

-5.85

19.50

20.49

-5.86

-5.95

20.50

21.49

-5.96

-6.05

21.50

22.49

-6.06

-6.15

22.50

23.49

-6.16

-5.86.2

23.50

-6.26

• Pressure is informed with the buzzer and the ink bottle lamp as well as the

screen display.

• For the negative pressure, the buzzer stops within the range of ±0.1kPa. For the

positive pressure, the buzzer stops within the range of ±1.0kPa.

Ink bottle lamp

JFX500:

UJV500:

Ink bottle lamp

P L EASE WA I T