7.1.2 List of Error Messages
List of Error Messages (1/4)
Error
No.
Indication on LCD
Cause
Remedy
01
***** ERROR 01 *****
MAIN ROM
An error occurs on the control PCB (ROM)
Turn off the main power, and turn it on a little later.
If the error occurs again, carry out the followings.
1.
Replacement of the Main PCB Assy (
02
***** ERROR 02 *****
MAIN RAM
An error occurs on the control PCB (RAM)
03
***** ERROR 03 *****
POWER +5V
An error occurs on the control PCB
(Power v5V)
Turn off the main power, and turn it on a little later.
If the error occurs again, carry out the followings.
1.
2.
Replacement of the Main PCB Assy (
***** ERROR 03 *****
POWER +24V
An error occurs on the control PCB
(Power v24V)
***** ERROR 03 *****
POWER +42V
An error occurs on the control PCB
(Power v42V)
04
***** ERROR 04 *****
F-ROM
An error occurs on the control PCB
(Parameter ROM)
Turn off the main power, and turn it on a little later.
If the error occurs again, carry out the followings.
1. After uploading parameters, initialize all
parameters.
If the state is not restored, replace the main
PCB assy with a new one.
06
***** ERROR 06 *****
SD-RAM
An error occurs on the control PCB
(SDRAM)
Turn off the main power, and turn it on a little later.
If the error occurs again, carry out the followings.
1.
Replacement of the Main PCB Assy (
2.
07
***** ERROR 07 *****
HEAD (----)
An error was detected in the head connection.
(Abnormal temperature was detected.)
Turn off the main power, and turn it on a little later.
If the error occurs again, carry out the followings.
1. Reconfirm the head temperature with [#TEST]
-> [TEMP.CHECK] -> [NOZZLE TEMP.].
If the abnormality occurs again, carry out the
followings.
2. Make sure that corresponding FFC, main FFC
are connected in the right way.
3. Replace the head.
4.
5.
Replacement of the Main PCB Assy (
6.
***** ERROR 07 *****
VOLTAGE (----)
An error was detected in the head connection.
(Abnormal voltage was detected.)
08
***** ERROR 08 *****
LinearENCODER: SENSOR
An error occurred in detection by the linear
encoder. (Counting impossible)
Turn off the main power, and turn it on a little later.
If the error occurs again, carry out the followings.
1. Check of the mounting location for the linear
encoder scale and encoder PCB assy.
2.
***** ERROR 08 *****
LinearENCODER: DIR.
An error occurred in detection by the linear
encoder. (Wrong orientation)
***** ERROR 08 *****
LinearENCODER: COUNT
An error occurred in detection by the linear
encoder. (Read-out count error)
09
***** ERROR 09 *****
FPGA ERROR
An error occurs on the control PCB
(FPGA PDC)
Turn off the main power, and turn it on a little later.
If the error occurs again, carry out the followings.
1.
Replacement of the Main PCB Assy (
2. Replacement of the HDC PCB Assy.
***** ERROR 09 *****
HDC ERROR (----)
An error occurs on the control PCB
(FPGA HDC)
***** ERROR 09 *****
FPGA PRAM BUSY
An error occurs on the control PCB
(FPGA HDC)
illegal IPT xxx
xxxxxxxx
CPU
不正割り込みが発生
Turn off the main power, and turn it on a little later.
If the error occurs again, carry out the followings.
1.
Replacement of the Main PCB Assy (
Prg Err TK=xxx ASSRT
[xxxx] [xxxx] [xxxx]
プログラムエラーを警告
10
***** ERROR 10 *****
COMMAND ERROR
Other data than commands is received.
1. Clear the data of uncompleted printing.
2. Check the USB cable.
(specifications, cable length, etc.)
3.
Replacement of the Main PCB Assy (
11
***** ERROR 11 *****
PARAMETER ERROR
Parameter out of the numeral value range is
received.
1. Clear the data of uncompleted printing.
2. Check the USB cable.
(specifications, cable length, etc.)
3.
Replacement of the Main PCB Assy (
MAINTENANCE MANUAL > Troubleshooting > Details on Errors and Malfunctions > List of Error Messages
Model
TS34-1800A
Issued 2011.10.17 Revised
F/W ver
1.20
Remark
1.0