© 2011 MIMAKI ENGINEERING CO.,LTD.
6.3.5
P.1
6.3.5 Linear Encoder Scale
Work procedures
1. Remove the following covers.
• Front cover
• Y cover F
• Maintenance cover
2. Remove the
Encoder PCB Assy
.
3. Remove the screws from the right end of the linear encoder
scale, and detach the
linear encoder scale
.
4. Remove the screw from the left end of the linear encoder scale,
and detach the
linear encoder scale
together with the springs.
5. Remove the
scale hook
and
scale holder L
from the linear
encoder scale.
Turn the main power OFF when turning the power OFF. It is very dangerous if sleep mode functions
mistakenly during the operation.
While at work, be sure not to attach fingerprints or oil to the linear encoder scale. Also, pay attention not
to break or scratch it. (If contaminated, clean the scale with a neutral detergent.)
Linear Encoder Scale
Linear Encoder Scale
Scale Holder R
Linear Encoder Scale
Spring
Scale Holder L
Scale Hook
R.1.0
MAINTENANCE MANUAL > Disassembly and Reassembly > Drive System > Linear Encoder Scale
Model
TS34-1800A
Issued 2011.10.17 Revised
F/W ver
1.20
Remark
1.0