5.1.9 [MOTOR TEST] WIPER MOTOR
Function
Operation test of wiper motor is executed.
Operation Procedures
Step
Item
Description
Remarks
1
Driving speed designation
[
], [
] : Selects driving speed of the motor.
Set value: 100 – 4000 pps (unit: 100 pps)
[
], [
] :
Selection of items 1 – 3
2
WAIT designation
[
], [
] : Designates operation interval.
Set value: 0 – 60 sec. (unit: 1 sec.)
3
Count designation
[
], [
] : Designates No. of operation.
Set value: CONTINUE, 1 – 1000 count (unit: 1 count)
4
Test start
[ENTER]: Drives the motor with designated conditions.
When CONTINUE is selected from the count
setting, press [END] to finish the test.
5
End
Return the wiper to the original position.