© 2013 MIMAKI ENGINEERING CO.,LTD.
6.7.3
P.1
R.1.1
MAINTENANCE MANUAL > Disassembly and Reassembly > Repeated winding relations > Feeding Motor assy.
Model
SWJ-320S
Issued 2012.07.19 Revised 2012.08.17 F/W ver
Remark
1.1
6.7.3 Feeding Motor assy.
Work procedures
1. Turn off the main power supply and remove the power plug
from the main body.
2. Remove the following covers.
• Feeding/take-up left side cover
3. Remove the terminal block cover, and disconnect the feeding
motor cables (A4, A17, A18) from the terminal block, loosen-
ing the screw.
キ
4. Remove the
feeding gear cover
.
5. Remove the
feeding roller shaft bearing left
.
6. Loosen the set screw, and remove the
feeding motor gear
.
7. Remove the screw, and remove the
feeding motor assy.
.
8. Reverse the disassembly procedure for reassembly.
After turning off the sub and main power switches, unplug the power cord. Make sure to take 15
minutes before restarting the operation. It is very dangerous if sleep mode functions mistakenly
during the operation.
Additionally, if electric charges are still remaining, it may cause damage to electronic parts or the like.
Feeding/take-up left side cover
Feeding gear cover
Feeding motor assy.
Terminal block
Loosen the screw.
Feeding motor assy.
Feeding roller shaft bearing left
screw(x4)
Set screw
Feeding motor gear
screw(x4)
The feeding motor assy. is a complete assembly
consisting of the motor and gear head. Do not dis-
assemble the motor and the gear head.