Filling of discharge liquid at the time of starting works
If the discharge liquid in this machine has used in the long period, it may cause the de-
crease in the print head life. In order to prevent the shortening of the life of the head for
discharge liquid, the discharge liquid contained is replaced by cleaning liquid when it is not
used for an extended period of time. At the time of starting works, the cleaning liquid filled
in the head for discharge liquid is to be drained and the discharge liquid is filled in.
STEPS:
1.
At the LOCAL state, press the
[FUNCTION] key 4 times.
2.
Press the [ENTER] key.
3.
Use up/down keys to select
[Discharge].
4.
Press the [ENTER] key.
5.
Open the station cover.
6.
Turn the all valves to [DCG].
7.
Close the station cover.
8.
Press the [ENTER] key.
9.
Fill up the discharge liquid after
initializing this machine.
10.
It indicates the remaining
run-time.