7.3.1 PCB Damage Checksheet
Please fill out this checksheet to search failure sources of head and PCB damage.
We would appreciate your taking time to complete this checksheet
Please confirm the machine which has had countermeasure or not.
Some countermeasure are not completed. ........................................Work on uncomplied countermeasure.
Complied countermeasure. .................................................................Fill out following A) through E) and attach to the Damage Report.
A> Fill out the machine information,
B> Conditions when trouble occurred.
1. Confirmation for countermeasure of the selected models.
JV33-130/160, TS3-1600
Firmware Version 4.00 or later.
Main PCB revision label : [
E104853-*1 Pb/F] or [
E105997-A Pb/F] (* = A to G)
Completed countermeasure for HDC FFC disconnection of movable parts.
JV33-130BS/160BS
Firmware Version 3.00 or later.
Main PCB revision label : [
E105454-*1 Pb/F] or [
E105998-A Pb/F] (* = A to G)
JV33-260, TS3-2600
Firmware Version 4.00 or later.
JV33-260BS
Firmware Version 3.00 or later.
CJV30-60/100/130/160, CJV30-60BS/100BS/130BS/160BS, TPC-1000
Firmware Version 2.00 or later.
Damage Date)
Installation Date)
Serial Number
Ink Type
Ink Set
SS21
ES3
BS
Other : [ ]
4 color
6 +W color
6 color
Other : [ ]
1. Check the conditions below.
Unable to turn ON the machine.
LCD light do not turn on.
LCD light is on but nothing displayed.
Abnormal ink firing.
Ink firing with particular nozzle line as once.
No ink firing with particular nozzle line.
Error displayed on LCD pannel.
Check the Error Code/Message displayed on LCD as below.
Also fill in the timing and frequency of error occurrence. Ex. [Everytime occur at test drawing]
Error code/Message
Occurred [Timing/Frequency]
ERROR 07
HEAD
VOLTAGE
ERROR 50
MEDIA DETECT
MEDIA SET POSITION
ERROR 200 HEAD MEMORY
ERROR 202 DEVICE CONSTRUCTION
ERROR 205 47V HEAD VOLTAGE
ERROR 207
OVERFLOW
UNDERFLOW
SLEW RATE
Other (describe problem specifically)
2. How and in which condition the trouble occurred?