6.2.6 Cap Assy
Work procedures
1. Turn off the main power supply of the printer.
2. Manually move the head unit over the platen.
3. Remove the following covers.
•
Station Cover U
• Wiring Cover
4. Remove the
W ink guard
.
5. Remove two tubes from the
CP coupler
.
6. Remove the screws, and then remove the
cap assy
while
turning back the PC pipe.
7. Reverse the disassembly procedure for reassembly.
Be sure to turn off the main circuit breaker to prevent unexpected movements of the printer.
Cap Assy
W Ink Guard
CP Coupler
Screw
Cap Assy
Screw
At the time of assembly, screw up the cap assy while
striking it against a recess.