© 2009 MIMAKI ENGINEERING CO.,LTD.
4.3.1
P.1
R.1.1
Maintenance Manual > Adjustment Items > Mechanical Adjustment > Adjusting the Location of Mark Sensor
Model CJV30/TPC Issued 2008.08.04 Revised 2008.09.17 F/W ver. 1.20 Remark
1.1
4.3.1 Adjusting the Location of Mark Sensor
Function
Adjust the distance between the mark sensor (photo sensor) and the platen to the specified value.
Procedure
1. From the back side of the printer, loosen the screws that hold
the T sensor BKT.
2. Insert the clearance gauge between the pen line film and the
bottom surface of the T sensor cover.
3. Check whether the right and left T sensor covers are fixed under
the conditions that each of them is in close contact with the
clearance gauge, then tighten up the screws.
Set the pressure of all the clamps to Middle, and make the adjustment on the right station side.
This adjustment is to be made mechanically without using any [#ADJUST] item. After completion of
this adjustment, however, make the adjustments of [PHOTO SENSOR] among the [#ADJUST] items.
2.8 mm
T Sensor BKT
Loosen
When no sheet is set: the plotter waits for input of a
compensation value without plotting.
Jig for adjusting the height
of CJV mark sensor
T Sensor Cover
Fix.
Press against.
Содержание CJV30 Series
Страница 315: ......
Страница 316: ...Printed in Japan D500387 13 05112010 2010 MIMAKI ENGINEERING CO LTD IT FW 2 5...