GUIDE TO DISPLAY CODES: 
 

This prompt appears for 1 second  each 
time the instrument is turned on.  
 
The dashes “-  -  -” 
indicates 

that the 

meter is in a ready 
state  and zeroing can 
be performed.  
 
Sampling In Progress. 
Flashing  “SIP” prompt 
appears each time the 
meter is performing a  
measurement. 
 
“-0.0-”, the meter is in 
a zeroed  state and 
measurement can  be 
performed.  
 
The blinking "BAT" 
indicates 

that the 

battery 

voltage is 

getting  low and the 
battery  needs to be 
replaced. 
 
“-bA-”, the battery is 
dead and  must be 
replaced. Once this 
indication is displayed, 
the meter will lock up. 
Change the  battery 
and restart the meter. 
 
“Conf”, the meter has 
lost its  configuration. Contact your  dealer 
or the nearest Martini  Customer Service 
Center. 
 
 

 
 

ERROR MESSAGES 
 
On zero reading 
 

• Blinking “-0.0-” indicates that the zeroing 
procedure  failed due to a low signalto-
noise ratio. In this 
case 
press ZERO again. 
• “no L”, the 
instrument can not 
adjust the light 
level. Please check 
that the sample 
does  not contain 
any debris. 
• “L Lo”, there is 
not enough  light to 
perform a 
measurement.  
Please check the 
preparation of the 
zero cuvet. 
• “L Hi”, there is too 
much 

light to 

perform a 
measurement. 
Please check the preparation of the zero 
cuvet. 

 
On sample reading 

• “-SA-”, there is too 
much  light for the 
sample 
measurement. 
Please check if  the 
right sample cuvet is 
inserted. 
• “Inv”, the sample 
and the  zero cuvet 
are inverted. 
• “ZErO”, a zero 
reading was 

not 

taken. Follow the instruction  in the 
measurement  procedure for zeroing  the 
meter. 
 
• Under range. A blinking  “0.00” indicates 
that the 

sample 

absorbs less light 
than the zero 
reference. 
Check the procedure 
and  make sure you 
use the  same cuvet 
for reference  (zero) 
and measurement. 
• A flashing value of 
the 

maximum 

concentration 
indicates  an over 
range condition. 
The concentration of the sample is beyond 
the  programmed range: dilute  the sample 
and re-run the test. 
 
 
 

BATTERY REPLACEMENT 
 

Battery replacement must only take place 
in a non-hazardous environment. 
Simply rotate the battery cover on the back 
of the meter. 
Detach the 
battery from 
the terminals 
and attach a 
fresh 9V 
battery while 
paying 
attention to 
the 

correct 

polarity. 
Insert the battery and replace the cover. 

 
 
 

ACCESSORIES: 
 

MI513-045  

Free & Total Chlorine 

 

reagent set (45 tests) 

MI0001  

Glass cuvets (2 pcs) 

MI0002  

Caps for cuvets (2 pcs) 

MI0003  

Stoppers for cuvets (2 pcs) 

MI0004  

Tissue for wipping cuvets 

 

(4 pcs) 

MI0005  

9V battery (1 pc) 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

WARRANTY 
 

This instrument is warranted against defects in 
materials and manufacturing for a period of two 
years from the date of purchase. 
If during this period the repair or replacement of 
parts is required, where the damage is not due 
to negligence or erroneous operation by the 
user, please 
return the meter to either distributor or our office 
in the original packing and the repair will be free 
of charge. 
Damages due to accidents, misuse, tampering 
or lack of prescribed maintenance are not 
covered. 