3
Place the drain cleaner at a distance no greater
cleaner cannot be placed within 610mm from the
drain opening, the drain opening will need to be
Greater distances can cause control problems leading
to twisting, kinking, breaking or whipping of the cable.
One person must control both the trigger switch
and cable.
If the tool stops rotating, the user must be
able to turn the tool off to prevent twisting, kinking,
breaking or whipping of the cable.
Do not operate the drain cleaner in reverse rotation
except as described in this manual.
Running the tool
in reverse for extended periods can cause damage to
the cable and accessories.
WARNING
-
jury, and product damage due to a
short circuit, never immerse your tool, battery pack or
certain industrial chemicals, and bleach or bleach
containing products, etc., can cause a short circuit.
Maintain labels and nameplates.
These carry im-
portant information. If unreadable or missing, contact
a
MILWAUKEE
service facility for a replacement.
WARNING
Some dust created by power sanding,
sawing, grinding, drilling, and other
construction activities contains chemicals known to
cause cancer, birth defects or other reproductive harm.
Some examples of these chemicals are:
lead from lead-based paint
crystalline silica from bricks and cement and other
masonry products, and
arsenic and chromium from chemically-treated lumber.
Your risk from these exposures varies, depending on
how often you do this type of work. To reduce your
exposure to these chemicals: work in a well ventilated
area, and work with approved safety equipment, such
as those dust masks that are specially designed to
SPECIFICATIONS
Cat. No. ...............................................M18 FFSDC16
Volts ...................................................................18 DC
No Load RPM ........................................................250
Battery Type ..................................................... M18™
Charger Type .................................................... M18™
Drain Line Capacity..................................Up to 30.5m
Cable Range..........................8mm-16mm (5/16"-5/8")
Tool Weight (With Battery)..................................7.8kg
SYMBOLOGY
Volts
V
Direct
Current
No-Load Revolutions per Minute (RPM)
Do not allow battery to contact corrosive
Only wear leather gloves
Do not transport this tool when the
drum and backpack are connected
-
tacts eyes, additionally seek medical help.
Liquid
ejected from the battery may cause irritation or burns.
Do not use a battery pack or tool that is damaged or
risk of injury.
-
cessive temperature.
above 130°C (265°F) may cause explosion.
Follow all charging instructions and do not charge
the battery pack or tool outside the temperature
Charging im-
SERVICE
person using only identical replacement parts.
This will ensure that the safety of the power tool is
maintained.
Never service damaged battery packs.
Service of
battery packs should only be performed by the manu-
facturer or authorised service providers.
SPECIFIC SAFETY RULES
Only grasp the rotating cable with gloves recom-
mended by the manufacturer.
gloves or rags can become wrapped around the cable
and may result in serious personal injury.
Do not allow the cutter to stop turning while the
cable is turning.
This can overstress the cable and
may cause twisting, kinking or breaking of the cable
and may result in serious personal injury.
Use latex or rubber gloves inside the gloves rec-
ommended by the manufacturer, goggles, face
shields, protective clothing, and respirator when
chemicals, bacteria or other toxic or infectious sub-
stances are suspected to be in a drain line.
Drains
may contain chemicals, bacteria and other substances
that may cause burns, be toxic or infectious or may
result in other serious personal injury.
Practice good hygiene. Do not eat or smoke while
handling or operating the tool. After handling or
operating drain cleaning equipment, use hot, soapy
water to wash hands and other body parts exposed
to drain contents.
This will help reduce the risk of health
hazards due to exposure to toxic or infectious material.
Only use the drain cleaner for the recommended
drain sizes.
Using the wrong size drain cleaner can
lead to twisting, kinking or breaking of the cable and
may result in personal injury.
Inspect cable for wear and damage before use.
Replace a worn or damaged cable before using the
drain cleaner.
Do not twist, kink or over bend cables.
Breaking of
the cable may result in serious personal injury.
Inspect the drain to be cleaned before use.
If pos-
sible, determine the access point(s) to the drain, the
size(s) and length(s) of the drain, distance to mainlines,
the nature of the blockage, presence of drain clean-
ing chemicals or other chemicals, etc. If chemicals
are present in the drain, it is important to understand
those chemicals. Contact the chemical manufacturer
for required information.
If needed, place protective covers in the work area.
The drain cleaning process can be messy.
Make sure cable is fully retracted inside of the drain
cleaner.
This will prevent whipping at start up.
than 610mm from drain opening. If the drain
®
n
o
xxxxmin.
-1
Regulatory Compliance mark (RCM).
This product meets applicable
regulatory requirements.
Содержание M18 FFSDC16