background image

3

READ AND SAVE 

ALL INSTRUCTIONS 

FOR FUTURE 

REFERENCE.

SYMBOLOGY

Volts

Direct Current

Amps

Read Operator's Manual

SPECIFICATIONS

Charger Cat. No.  ......................................M12 TC

Input....................................................5 VDC, 2.1 A

USB Output ........................................9 VDC, 1.6 A

5 VDC, 2.1 A

Operating Temperature 

   Battery and Charger ..........................4°C to 40°C

(40°F to 104°F)

   Battery and Tool ..............................-18°C to 75°C

Power Supply Cat. No. ...................4931 4605 95A 

Wall Plug Input Volts ...........................100 - 240 AC 

Battery Cat. No........................................... M12B2

Volts .............................................................. 12 DC

Battery Cat. No........................................... M12B3

Volts .............................................................. 12 DC

Battery Cat. No........................................... M12B4

Volts .............................................................. 12 DC

Battery Cat. No........................................... M12B6

Volts .............................................................. 12 DC

FUNCTIONAL 

DESCRIPTION

1. USB A port (output)

2. Power cable port (output)

3. Charging indicator LEDs

4. Micro-USB port (input)

5. USB power button

6. Fuel gauge

7. Contacts

8. Release buttons

9. Micro-USB Cable

10. Micro-USB

11. USB A

12. Wall plug prongs

13. Wall plug USB A port (output)

1

2

3

4

5

6

10

7

12

9

11

8

MILWAUKEE

®

 

LI-ION 

BATTERY PACKS

Maintenance and Storage

Do not expose your battery pack or cordless tools 

to water or rain, or allow them to get wet. This could 

damage the tool and battery pack. Do not use oil or 

solvents to clean or lubricate your battery pack. The 

plastic casing will become brittle and crack, causing 

a risk of injury.

Store battery packs at room temperature away from 

moisture. Do not store in damp locations where cor-

rosion of terminals may occur. As with other battery 

pack  types,  permanent  capacity  loss  can  result  if 

the pack is stored for long periods of time at high 

temperatures  (over  65

o

C). 

MILWAUKEE

® 

  Li-Ion 

battery packs maintain their charge during storage 

longer than other battery pack types. After about a 

year of storage, charge the pack as normal.

Transport

Personal transport of Li-Ion battery packs is allowed 

when done in accordance with these warnings and 

-

beling, marking, and documentation requirements for 

shipping Li-Ion batteries is dependent upon whether 

the particular batteries are rated greater than or less 

than 100 Wh. Generally, Li-Ion batteries rated 100 

Wh or less are “excepted” from certain Class 9 DG 

requirements. Always  check  compliance  of  Li-Ion 

battery consignments against the current regulations 

governing the chosen mode of transport. When in 

doubt, contact the carrier or other trained Dangerous 

Goods  professional  to  confirm  acceptability.  Li-Ion

(0°F to 167°F)

Regulatory  Compliance  Mark 

(RCM).  Product  meets  applicable 

regulatory requirements.

Class III appliance

This  charger  was  only  suitable  for

indoor  use.  Never  expose  the

 

charger to rain.

13

Output to M12 Battery........................12 VDC, 0.7A

DC Output..........................................12 VDC, 1.5A

ADDITIONAL BATTERY 

SAFETY RULES

WARNING

To reduce the risk of fire,

personal injury, and product

damage due to a short circuit, never immerse 

your tool, battery pack or charger in fluid or 

allow a fluid to flow inside them. Corrosive or 

conductive fluids, such as seawater, certain 

industrial chemicals, and bleach or bleach 

containing products, etc., can cause a short 

circuit.

T3.0A

Time-lag fuse 3.0A

Отзывы: