background image

5

SYMBOLOGY 

 

  

  Volts

 

 

  Direct Current

 

 

  Alternating Current

 

 

 Amps

 

    Hertz

 

 

Lock

 

 

Power button

 

 

WARNING

  

Risk of Electric 

Shock

 

  Universal Serial Bus (USB)

 

   Universal Serial Bus Type-C 

(USB-C)

 

 

Do not allow battery to contact  

 

 

 

corrosive or conductive fluid.

 

 

Do not step

 

    Overload Indicator

 

 

  Overtemperature Indicator

 

BND

   Bonding  Terminal

 

BFP

  Backfeed Protected

 

 

Class II equipment with functional    

   grounding

 

C

US

 

UL Listing for Canada and U.S.

INSTALLATION

EXTENSION CORDS

Grounded tools require a three wire extension 

cord. Double insulated tools can use either a two 

or three wire extension cord. As the distance from 

the supply outlet increases, you must use a heavier 

gauge extension cord. Using extension cords with 

inadequately  sized  wire  causes  a  serious  drop  in 

voltage, resulting in loss of power and possible tool 

damage. Refer to the table shown to determine the 

required minimum wire size.

The smaller the gauge number of the wire, the greater 

the capacity of the cord. For example, a 14 gauge 

cord can carry a higher current than a 16 gauge cord. 

When using more than one extension cord to make 

up the total length, be sure each cord contains at 

least the minimum wire size required. If you are using 

one extension cord for more than one tool, add the 

nameplate amperes and use the sum to determine 

the required minimum wire size.

Guidelines for Using Extension Cords

•Do not exceed the load rating of the extension 

cord. Be mindful of the individual and accumula-

tive electrical load for all attachments. 

Exceeding 

the load capacity of the extension cord could result 

in overheating, fire, electrical shock, or injury.

• If you are using an extension cord outdoors, be sure 

it is marked with the suffix “W” to indicate that it is 

acceptable for outdoor use.

• Be sure your extension cord is properly wired and in 

good electrical condition. Always replace a damaged 

extension  cord  or  have  it  repaired  by  a  qualified 

person before using it.

• Protect your extension cords from sharp objects, 

excessive heat and damp or wet areas.

Recommended Minimum Wire Gauge

For Extension Cords*

Nameplate 

Amps 

Extension Cord Length

25'

50'

75'

100' 150'

0 - 2.0

2.1 - 3.4

3.5 - 5.0

5.1 - 7.0

7.1 - 12.0

12.1 - 16.0

16.1 - 20.0

18

18

18

18

16

14

12

18

18

18

16

14

12

10

18

18

16

14

12

10

--

18

16

14

12

10

--

--

16

14

12

12

--

--

--

* Based on limiting the line voltage drop to five volts at 150% 

of the rated amperes.

Содержание CARRY-ON 2845-20

Страница 1: ...WARNING To reduce the risk of injury user must read and understand operator s manual AVERTISSEMENT Afin de r duire le risque de blessures l utilisateur doit lire et bien comprendre le manuel ADVERTENC...

Страница 2: ...hed or grounded surfaces such as pipes radiators ranges and refrigerators There is an increased risk of electric shock if your body is earthed or grounded To reduce the risk of electric shock do not p...

Страница 3: ...a metal object makes a connection between the positive and negative contacts on the battery pack Do not place a battery pack near anything that may cause a short circuit such as coins keys or nails in...

Страница 4: ...ng status indicator light 4 total 7 Battery pack slots 8 Carrying strap loop 9 Fans 10 USB A port 1 2 4 5 6 7 8 9 10 11 12 14 15 16 17 18 11 USB C PD port 12 AC input 13 AC 120V AC receptacles 14 Bond...

Страница 5: ...cord to make up the total length be sure each cord contains at least the minimum wire size required If you are using one extension cord for more than one tool add the nameplate amperes and use the sum...

Страница 6: ...read the operator s manual supplied with your charger and battery Removing Inserting the Batteries To remove the batteries push in the release but tons and pull the battery packs away from the power...

Страница 7: ...charge as needed Compared to NiCd battery pack types MILWAUKEE Li Ion battery packs deliver fade free power for their entire run time The tool will not experience a slow gradual loss of power as you w...

Страница 8: ...hen the battery pack has reached the end of its charge To signal the end of charge the power supply will beep and flash the fuel gauge Charge the battery pack as needed How to Charge the Battery Pack...

Страница 9: ...power supply to a MILWAUKEE service facility for repairs WARNING To reduce the risk of personal in jury electric shock and damage never immerse your tool in liquid or allow a liquid to flow inside it...

Страница 10: ...S ATTORNEY FEES EXPENSES LOSSES OR DELAYS ALLEGED TO BE AS A CONSEQUENCE OF ANY DAMAGE TO FAILURE OF OR DEFECT INANYPRODUCTINCLUDING BUTNOTLIMITEDTO ANYCLAIMS FOR LOSS OF PROFITS SOME STATES DO NOT AL...

Страница 11: ...e tout autour de la source d alimentation Ne pas connecter la sortie de la source d alimentation au syst me d lectricit d un b timent La source d alimentation est isol e du cadre et de la broche mise...

Страница 12: ...les rincer abondamment l eau pendant 20 minutes et consulter un m decin Enlever et se d barrasser des v tements contamin s Ne pas court circuiter Un bloc piles court circuit pourra causer un incendie...

Страница 13: ...ie du bloc piles 4 en total 7 Rainures du bloc piles 8 Boucle pour courroie de transport 9 Ventilateurs 10 Port USB A 11 Port de puissance utile USB C 12 Entr e CA 13 R ceptacles CA 120 V CA 14 Borne...

Страница 14: ...C 40 F 105 F INSTALLATION CORDONS DE RALLONGE Grounded tools require a three wire extension Si l emploi d un cordon de rallonge est n cessaire un cordon trois fils doit tre employ pour les outils mis...

Страница 15: ...re reli une terminale sous tension Votre outil doit tre reli une prise appropri e in stall correctementetbienmis laterre Fig A selon les consignes qui figurent dans tous les codes et toutes les ordon...

Страница 16: ...eur sans air 1 3 HP 600 1 200 Radio 50 50 Chargeur standard M18 M12 48 59 1812 60 60 Chargeur rapide M18 M12 48 59 1808 75 M12 120 M18 75 M12 120 M18 Mode de vie Four micro onde 1 000 1 000 T l vision...

Страница 17: ...vertissement so nore V rifier la cause fondamentale de la sonnerie pour continuer l emploi Situations de surcharge et de temp rature extr me Si une situation de surcharge ou de temp rature ex tr me se...

Страница 18: ...le r ins rer Si le voyant de charge ne s allume toujours pas retirer les blocs piles et d brancher le chargeur pour au moins 2 minutes Apr s 2 minutes brancher le chargeur nouveau et ins rer le bloc p...

Страница 19: ...chariots de chantier industriels Trade Titan est d une dur e d un 1 an partir de la date d achat La p riode de la garantie pour les cl s chocs couple lev poign e en D de 1 M18 FUEL les c bles de netto...

Страница 20: ...el cargador jale el enchufe y no el cable Nunca transporte el cargador sujet ndolo del cable Proteja el cable del calor aceite y bordes filosos Aseg rese de no pisar tropezar o someter el cable a da...

Страница 21: ...toimpredeci ble causandoincendios explosionesoriesgodelesi n No aplaste tire o da e la bater a Siempre ponga las bater as en un contenedor seguro durante la transportaci n No utilice una bater a que h...

Страница 22: ...a 4 en total 7 Ranuras de bater as 8 Arillo de correa de transporte 9 Ventiladores 10 Puerto USB A 11 Puerto USB C PD 12 Entrada CA 13 Recept culos de CA 120 V CA 14 Terminal de equipotencializaci n...

Страница 23: ...emperatura ambiente recomendada para operaci n 0 C a 40 C 32 F a 105 F Temperatura ambiente recomendada para carga 5 C a 40 C 40 F a 105 F INSTALACI N EXTENSIONES ELECTRICAS Las herramientas que deben...

Страница 24: ...trav s del hilo verde dentro del cable El hilo verde debe ser el nico hilo conectado al sistema de conexi n de puesta a tierra de la herramienta y nunca se debe unir a una terminal energizada Su herr...

Страница 25: ...150 Tableta 15 15 Tel fono celular 5 5 El vataje enumerado es un aproximado Revise el vataje real de la herramienta o equipo Indicador de carga Useelindicadordecargapara Menos del 10 1 luz intermitent...

Страница 26: ...y utilizarla normalmente Funcionamiento en clima fr o Las bater as de ion de litio de MILWAUKEE est n dise adas para funcionar en temperaturas menores a cero Cuando la bater a est demasiado fr a es p...

Страница 27: ...VERTENCIA Para reducir el riesgo de le siones siempre desconecte la fuente de energ a y quite las bater as de los cargadores antes de realizar alguna labor de mantenimiento Nunca desarme la herramient...

Страница 28: ...trabajo es la misma que la vida til del producto sujeto a las limitaciones anteriores Si la l mpara LED o el foco LED falla durante el uso normal se cambiar la pieza sin costo No se requiere el regist...

Отзывы: