18
E.1
Change motor unit
1
2
Disassemble the handle, top cover, filter and hatch back as described in previous Section E.0.
Disconnect the full tank sensor wire and the motor wires from the PCBA and the switch (circles
in fig.1).
Unscrew the airguide over the motor (fig.1).
Replace the motor unit (Note: on low voltage motors the carbon brushes can be exchanged
once per motor).
Pay close attention to positioning the motor, gaskets and the wires correctly (see fig.2).
Then repeat the process backwards to assemble the machine.
Motor connection to
PCBA
Motor connection
to swicth
WARNING
: The upper section of the
machine contains live components.
Contact with live components leads
to serious or even fatal injuries.
Always disconnect the mains plug
before disassembly.
Full tank sensor
connection to PCBA
TIP: When placing the airguide into its
position put it in vertically.