FUNCTIONAL
DESCRIPTION
1. Contacts
2. Release buttons
3. Vents
4. Bay
5. Light indicators - when a
battery pack is inserted into the
charger, the light will indicate
the following situations:
Continuous red: Charging
Continuous green: Charging complete
Flashing red: Battery pack is too hot/cold-
Charging will begin when battery
reaches correct charging temperature
Flashing red/green: Damaged or faulty battery pack
5
3
2
1
4
SPECIFICATIONS
Cat. No. ............................................... 48-59-2401
Input Volts
....................................................
120 AC
Input Milliamps
.............................................
750 AC
Output Volts
..................................................
12 DC
Output Amps
................................................
3.0 DC
Cat. No. .................................................... 2510-20
Input Volts
....................................................
120 AC
Input Milliamps
.............................................
750 AC
Input Volts
.....................................................
12 DC
Input Amps
................................................... 4.4 DC
Output Volts
..................................................
12 DC
Output Amps
................................................
3.0 DC
Battery Cat. No.................................... 48-11-2401
Volts
..............................................................
12 DC
Battery Cat. No.................................... 48-11-2402
Volts
..............................................................
12 DC
Battery Cat. No.................................... 48-11-2420
Volts
..............................................................
12 DC
Battery Cat. No.................................... 48-11-2430
Volts
..............................................................
12 DC
Battery Cat. No.................................... 48-11-2440
Volts
..............................................................
12 DC
Battery Cat. No.................................... 48-11-2460
Volts
..............................................................
12 DC
Recommended Ambient
Charging Temperature ...................
40°F to 105°F
SYMBOLOGY
Volts
Direct Current
Alternating Current
Double Insulated
Properly Recycle Batteries
Hertz
Amps
mA
Milliamps
C
US
UL Listing for Canada and U.S.
MILWAUKEE
12V LI-ION
BATTERY PACKS
WARNING
To reduce the risk of fire, personal
injury, and product damage due to
a short circuit, never immerse your tool, battery
pack or charger in fluid or allow a fluid to flow
inside them. Corrosive or conductive fluids, such
as seawater, certain industrial chemicals, and
bleach or bleach containing products, etc., can
cause a short circuit.
Maintenance and Storage
Do not expose your battery pack or cordless tools
to water or rain, or allow them to get wet. This could
damage the tool and battery pack. Do not use oil or
solvents to clean or lubricate your battery pack. The
plastic casing will become brittle and crack, causing
a risk of injury.
Store battery packs at room temperature away from
moisture. Do not store in damp locations where cor-
rosion of terminals may occur. As with other battery
pack types, permanent capacity loss can result if
the pack is stored for long periods of time at high
temperatures (over 120° F). MILWAUKEE Li-Ion
battery packs maintain their charge during storage
longer than other battery pack types. After about a
year of storage, charge the pack as normal.
WARNING
To reduce the risk of injury or ex-
plosion, never burn or incinerate a
battery pack even if it is damaged, dead or com
-
pletely discharged. When burned, toxic fumes
and materials are created.
Disposing of MILWAUKEE Li-Ion
Battery Packs
MILWAUKEE Li-Ion battery packs are more environ
-
mentally friendly than some other types of power tool
battery packs (e.g., nickel-cadmium). Always dispose