Dial Position

Range

Resolution

Accuracy

Voltage AC/DC

400V

1000V

0.1V/1V

: ±(1.5% + 5 dgt) 45-500 Hz

: ±(1.0% + 2 dgt)

Current AC

200A

0.1A

±(3.0% + 3 dgt) 45-60 Hz

Resistance

Continuity

400.0

Ω

4.000k

Ω

40.00k

Ω

400.0k

Ω

4.000M

Ω

40.00M

Ω

0.1

Ω

0.001k

Ω

0.01k

Ω

0.1k

Ω

0.001M

Ω

0.01M

Ω

±(1.0% + 5 dgt)
±(1.0% + 2 dgt)
±(1.0% + 2 dgt)
±(1.0% + 2 dgt)
±(1.0% + 2 dgt)
±(2.0% + 5 dgt)

Capacitance (2206-20)

1000

μ

F

1

μ

F

±(1.9% + 2 dgt)

100.0

μ

F

0.1

μ

F

Current DC (2206-20)

400.0

μ

A

1000

μ

A

0.1

μ

A

±(1.0% + 2 dgt)

Temperature C° / F° 
(2206-20)

-40ºC ~ 400ºC

-40ºF ~ 752ºF

0.1°C

0.2°F

C°:±(1% + 2C°)
F°:±(1% + 3 F°)

Lo-Z

Lo-Z

Low Input Impedance
(2205-20)

400.0V

1000V

0.1V/1V

±(2.0% + 3 dgt) AC:45~500Hz

Functions 

FUNCTIONAL DESCRIPTION 

1. Light On/Off button

2. Hold button

3.  Jaws

4. Light

5. NCV indicator

6. Dial

7. Display

8. Terminal inputs

4

2

1

3

6

7

8

Cat. No. 
2206-20

Lo-Z

6

Cat. No. 
2205-20

5

ASSEMBLY

Selecting C° or F°

1. Turn Rotary Dial to OFF and

disconnect the test leads.

2. Unscrew and remove bat-

tery door and remove any
installed batteries.

3. Set the C°/F° switch to the

desired position.

4. Replace batteries according 

to “Loading/Changing the Batteries.

5.  Close the battery door and tighten screw se-

curely.

Loading/Changing the Batteries

Replace batteries when the Low 
Battery indicator   is displayed. 
1. Turn Rotary Dial to OFF and discon-

nect the test leads.

2. Unscrew and remove battery door.
3. Insert two (2) AA batteries, according 

to the polarity marked in the battery 
compartment

4.  Close the battery door and tighten screw

securely.

 WARNING 

To avoid an electrical hazard, turn the Rotary 
Dial to OFF and disconnect the test leads 
before opening battery compartment or 
replacing batteries.

OPERATION

Before Use

Confi rm the Rotary Dial  is set to the correct position, 
the instrument is set to the correct measurement 
mode, and the Data hold function is disabled. Oth-
erwise, desired measurement cannot be made.

LCD Backlight

The LCD backlight will turn off after about 3 minutes 
of inactivity. Push any button or turn the rotary dial 
to turn the backlight on.

Making a Measurement

 Voltage 

 DANGER 

To avoid electrical shock:
Never make measurement on a circuit in 
which voltage over AC 1000V or DC 1000V 
exists.
Do not use with the Battery Cover removed.
Keep  fi ngers behind the guards and away 
from test lead tips during measurements.

1. Set the Dial to

  posi-

tion.

2. Connect the red test lead

to the V

Ω

 terminal and the

black test lead to the COM
terminal.

3. 

AC: 

Connect the test leads

to the circuit under test. The 
reading is displayed.

DC: 

Connect the red test

lead to the positive (+)
side and black test leads
to the negative (-) side of
the circuit under test. The
reading is displayed. A reversed connection is
indicated as a negative value.

Current

1. Set the Dial to 

position.

2. Run the conduc-

tor through the
jaws. The read-
ing is displayed.

NOTE: 

Do not 

place 2 or more
wires between
jaws at the same 
time. Place wire between arrows. Otherwise,
irregular results will occur.

CAUTION 

Maximum conductor size is approx 5/8” 
diameter. 

 DANGER 

To avoid electrical shock:

Never make measurement on a circuit in 
which voltage over AC 1000V or DC 1000V 
exists. Jaws are designed not to short the 
circuit under test. If equipment under test has 
exposed conductive parts, however, extra 
precaution should be taken to minimize the 
possibility of shorting.

Do not use with the Battery Cover removed.

Disconnect the test leads from the instrument 
for current measurement.

Correct

Incorrect

Incorrect

Lo-Z

 

Low Input Impedance

(Cat. No. 2205-20 only)

Automatic voltage detection 
(AC or DC).
1. Set the Dial to 

Lo-Z

 posi-

tion.

2. Connect the red test lead

to the V

Ω

 terminal and the

black test lead to the COM
terminal.

3. 

AC: 

Connect the test leads

to the circuit under test. The 
reading is displayed.

DC: 

Connect the red test

lead to the positive (+) side
and black test leads to the negative (-) side of
the circuit under test. The reading is displayed.
A reversed connection is indicated as a negative 
value.

 WARNING 

Only use MILWAUKEE test leads with the 
MILWAUKEE
 Fork Meters.
Inspect test leads before each use. Use me-
ter to run a continuity test.