![MIL'S HOSPIVAC G EVISA E350 Скачать руководство пользователя страница 15](http://html.mh-extra.com/html/mils/hospivac-g-evisa-e350/hospivac-g-evisa-e350_start-up-and-maintenance-instructions_1794771015.webp)
HOSPIVAC G E350.R
E600.R
517463-07
13
EN
OUTLINE DIAGRAM
6.
6.1.
Mechanical architecture
6.2.
Direct start electrical architecture
Example of a composition with 3 vacuum pumps
On the front of the
PROCOM-2
or
CYCLIC 2020
box, there are two "CONTINUOUS" start buttons, one for
vacuum pump A, one for vacuum pumps B / C for 3 vacuum pumps version or one for pumps A / C / E and
one for pumps B / D / F for 4 / 5 / 6 pumps version.
These buttons are used to force the operation by passing the PROCOM-2 or CYCLIC 2020 card and the
safety vacuum switch(s).
This feature allows temporary troubleshooting or testing of vacuum pumps.
In "AUTO" position, the vacuum pumps are operated by PROCOM 2 or CYCLIC 2020 or by the safety vacuum
switch(s).
INSTALLATIONS
7.
7.1.
Dimensions of EVISA E350.R / E400.R / E500.R / E600.R vacuum pumps
A
ØM'
ØM
F
D
J
30
B
C
C'
H
H'
E
L
I
G
Exhaust : G3"
Suction : Flange DN80 threaded G3"
A
B
C
C'
D
E
F
G
H
H'
I
J
L
2xØM 2xØM'
E350
1360 680 544 614 145 260 510 510 408 458 376 462 814
M10
M10
E400
1400 680 544 614 145 331 510 510 477 477 376 462 884
M10
M10
E500
1460 680 544 614 145 364 510 510 512 512 376 464 918
M10
M10
E600
1655 680 544 611 145 411 512 510 558 558 376 464 965
M10
M10
Main switch
[B / C]
Main switch
[A]
Button for [A]
automatic operation
or continuous
operation
Button for [B / C]
automatic operation
or continuous
operation
C2V
Network sensor
C1V
Regulation sensor
Power supply
terminal block
[B / C]
Power supply
terminal block
[A]
Safety
vacuum switch
Motor connection
B & C
Motor connection
A
Содержание HOSPIVAC G EVISA E350
Страница 43: ......