Chapter 3. MilTouch Wash Formulas
PELLERIN MILNOR CORPORATION
Early, After, Runs
—Start steaming
before
level is achieved, subsequent steaming
allowed
;
timer
runs
.
Early, Stops
—Start steaming
before
level is achieved, subsequent steaming
not allowed
; timer
stops
until temperature is achieved.
Early, After, Stops
—Start steaming
before
level is achieved, subsequent steaming
allowed
;
timer
stops
until temperature is achieved.
3.1.2.9.
C = Chemicals
—There may be more than one chemical decision per step because multiple
chemicals may be added to a single bath.
If the chemical numbers and names shown below do not correspond to how your machine is set
up, do not use the default formulas without first testing and modifying the chemical injection
values.
0
—no chemical injection commanded
1
—inject chemical 1, usually
alkali
for 36-inch or larger models;
detergent
for other models
2
—inject chemical 2, usually
detergent
for 36-inch or larger models;
bleach
for other models
3
—inject chemical 3, usually
bleach
for 36-inch or larger models;
sour
for other models
4
—inject chemical 4, usually
softener
5
—inject chemical 5, usually
starch
; also used to signal that a ChemSave machine desires to
inject chemical
3.1.2.10.
W = When to Inject Chemicals
—At what point in the step is this chemical to be injected?
With Fill
—Begin injecting the chemical
when the water valves open
.
Level OK
—Begin injecting the chemical when the commanded
bath level is achieved
.
Level + Temp
—Begin injecting the chemical when the commanded
bath level and temperature
are achieved
.
3.1.2.11.
Chemical Dose = Chemical Injection Duration
—How long should the chemical
injection continue?
00 00 00
—0 seconds; chemical injection prohibited
00 00 40
—40 seconds; default value
00 02 59
—119 seconds
3.1.2.12.
Signal with Chemical Injection
—Should the machine operator be notified when this
chemical injection is desired?
No
—The chemical injection occurs automatically without operator notification or intervention.
Yes
—The machine will signal the operator when this chemical injection is desired. The operator
must cancel the signal before the injection will occur.
3.1.2.13.
Wash Speed
—Should this step employ normal wash speed or high wash speed?
Normal
—This is the
normal wash speed
. This speed is the default value for factory-supplied
formulas and new bath steps.
Low
—This is wash speed 2. This is a
slower wash speed
.
3.1.2.14.
Drain Type
—What type of drain action is desired for this step? This decision may also affect
the fill action.
30